ArtNet DMX-UNIVERSE 4.1
5
Please call the IP 2.0.0.10 in the address bar of the web browser for getting the
following configuration page:
The
ArtNet-DMX-UNIVERSE 4.1
has
2 ArtNet Nodes which can be configured
separate.
Each Node needs an own
IP-address,
so the assignment in the network
occurs clearly. According to the ArtNet-specifications please use the IP-
addresses 2.x.x.x or 10.x.x.x.
For an easier identification you can assign each node with any names.
The
Short-name
is limited to 18 signs and the
Long-name
to 64 signs.
The
Subnetmask
is left to 255.0.0.0 according to the ArtNet-specifications.
In an event of a DMX-signal failure (
DMX FAIL
) several actions can be selected for
the DMX-input.
NO DATA
- with ArtNet no DMX-input will be received
HOLD last DMX data
- the last data will retained
CLEAR all DMX channels to 0% - all DMX-input channels will be set on 0
SET all DMX channels to 100%
- all DMX-input channels will be set on 255