background image

7.2m  9.6m 

10ft

7ft
5ft

0ft 

0ft 

10ft 

20ft 

30ft 

40ft 

50ft

0m 

2.4m 

4.8m 

12m

ODT-8250 DMT 

Dual-MW outdoor detector installation manual

1.Simple introduction
      

ODT-8250 DMT adopts the dual-micro outdoor intruding detector which

 includes  energy-pile-up logical process ,logic dynamic  time split technology. 

It is the best choice of outdoor intruding detector for finance industry, business

 and garden resident.        

        ODT-8250 DMT,the part of PIR adopts sophisticate columnar FRESNEL 

technology, advanced radian design to improve the efficiency of energy receiving. 

And combine the MW and PIR technoloy. MW detecting area and the PR detecting 

area are overlap. High sensitivity but do not have any fault arming. The part of the 

MW can caculate out the moving objects's speed and volume ans so on. 

Cooperating with the advanced patent software technology can help make the 

accurate judgement between the real intruder and some other interference resulting

in fault arming. Have a super high performance of detecting and anti-fault arming.

3.Installation 

PIR channel

2.Specification

product name

ODT-8250 DMT

input voltage

12 VDC

most current62mA

meeting point rating 3W

125mA

most current

25 VDC

most voltage(DC resistent load);

             sharing with the relay use the "C" down-lead's 4.7

1/2W resistant to protect

             Remark

Please do not use on the load of capacitance or inductance

temperature rang

-10

C to +50 C.

MW frequency 

0D850-F1

10.525GHz

           0D850-F2:  10.588GHz

covering range

12m*12m

É Ï ¸ Ç

Ϡ ¸ Ç

P/N:20090801A01

25ft

15ft

5ft

0ft

1.5m

4.5m

7.5m 

0ft 

10ft 

20ft 

30ft 

40ft 

50ft

7.2m 

9.6m 

0m 

2.4m 

4.8m 

12m

Please do not install the detector in the position of PIR or MW always in the status of alarming (LED is on). After right installation, turn down the LED. 
Please do not towards to the direction of car driving. 
Avoid installing at the place  as the hanging sign and the trees can be blowed by the wind, and the other things at the place of sub-corving zone , 
and the corving zones where  the  wildness animals can intrude  .Please check that the installing place is steady and non vibration.

Warning!!!

Warning!!!

Only after all the connection, then can turn on the power. Please do not place the detector at the area
 with the redundant curing wiring. Please do not connect the terminals to the 25VDC power.
SELV
Some countries request the relay should be connected to the circuit with the SELV

Only after all the connection, then can turn on the power. Please do not place the detector at the area
 with the redundant curing wiring. Please do not connect the terminals to the 25VDC power.
SELV
Some countries request the relay should be connected to the circuit with the SELV

3.2 Installing step
    

A. Use the screwdriver to open t

     he top and then install 

DIP swtich

tapmer switch

MW adjust

cable outlet

cable outlet

wiring hole

used after 

the pulling

A. Drill at installing place

B. Induct the wiring to the shell from the back

C.fix the bottom shell in the wall with the 

    screwdriver 

D. Combine the upper and lower lids 

descriptions 

Can choice the underside 

installation, install on the wall with the 45,
bracket installing . And the bracket installing 
is the most convenient way.

Back is the bracket installing place

bracket is optical 

Отзывы: