Operating Determinations 

 

The relative humidity must not exceed 50% with an ambient temperature of 40°C. 

 

If this product is operated in any other way, than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property ! 

 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 
 

 

Содержание 100263

Страница 1: ...PLB 2342FM V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 100263 MANUAL ENGLISH ...

Страница 2: ...B 2342FM bracket 2 Safety Instructions 3 Operating Determinations 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Installation 5 Set Up and Operation 5 Wood Stud Wall Mounting 5 Solid Brick and Concrete Block Mounting 7 Installation 8 Maintenance 13 Product Specifications 13 ...

Страница 3: ...om shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes DMT PLB 2342FM bracket User manual Tools required for installing the PLB 2342FM bracket Phillips head screwdriver 200 mm length ex...

Страница 4: ... Never leave any cables lying around Do not begin the installation of this product before you have read the entire manual Firmly tighten the screws but do not overtighten Overtightening can damage the bracket thereby greatly reducing its holding power When mounting the bracket to wood wall studs make sure that the mounting screws are anchored into the center of the studs Use of an edge to edge stu...

Страница 5: ...gestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or vis...

Страница 6: ...supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Wood Stud Wall Mounting Use a 4 5 mm drill bit wood to drill the holes hole size 4 5 mm hole depth 55 mm Make sure that the supporting surface will safely support the combined load of the equipment and all...

Страница 7: ...3 PLB 2342FM The provided hardware is for mounting through or attachment to a standard thickness drywall or plaster into studs Installers are responsible for providing the hardware for other types of mounting situations ...

Страница 8: ...te anchors Do not drill into mortar joints Be sure to mount on a solid part of the block with a 1 minimum from the side of the block You should use an electric drill at low speed to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity The installer must verify if the supporting surface will safely support the combined load of the equipm...

Страница 9: ...tion 01 Select the desired height Use the wall bracket as a template and mark the drilling locations for wood studs please detect the center with a stud finder Make sure that the alignment is correct 02 Drill pilot holes at marked locations ...

Страница 10: ...your flat screen 04 Align the screen bracket with the VESA hole pattern on the back of the flat screen Insert the appropriate screws from the Monitor Kit M A or M B 05 Use a Phillips screwdriver to tighten the screws when installing onto a wood stud the anchors are not needed ...

Страница 11: ...en using the longer M B screws you can also use the additional plastic rings M C 07 Screw 2 screws W A into the wall but do not tighten just yet and let the bracket slide into the holes 08 After that screw the 3rd screw W A into the hole ...

Страница 12: ...11 Ordercode 100263 PLB 2342FM 09 Tighten all 3 screws with a Phillips screwdriver 10 Attach the 2 plastic caps to protect the bracket and its screws ...

Страница 13: ... 2342FM 11 Attach the cable management system 12 Loosen the screw to set the inclination angle 13 Tilt the Monitor TV to the desired position and tighten the screw again 14 Guide all cables through the cable management system ...

Страница 14: ...ice or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanically moving parts like axles eyes and others may not show any traces of wearing 04 The electric power supply cables must not show any damages or material fatigue Product Specifications Model DMT PLB 2342FM Maximum Load 20 kg S...

Страница 15: ...14 Ordercode 100263 PLB 2342FM ...

Страница 16: ... 2021 DMT ...

Отзывы: