All  QS5  series  corrosion  and  thickness  gauges  are  for  industrial  use 
only and cannot be used in medical applications. The QS5 operates on 
two AA size batteries. We strongly recommend that you use only top 
brand name alkaline batteries.  
Disposal  of  your  QS5  gauge  and  its  components  must  be  done  in 
compliance with all applicable regulations.  
 

Because of its complexity level, software is never really completely error 
free.  For  this  reason  in  software  controlled  instruments  always  make 
sure  that  the  operations  required  for  your  application  are  in  correct 
working order. 
 

Demeq S.R.L provides a limited warranty for a period of 2 (two) years 
on electronic units and for 6 (six) months on transducers from the date 
of purchase and may be extended for up to 5 years.    
Every instrument undergoes thorough testing during manufacturing as 
well as before shipping. In the event warranty service where to become 
necessary,  dmq  and  or  your  local  distributor  or  representative  will 
make  a  reasonable  effort  to  replace  your  defective  unit  with  another 
new or used unit, while your instrument undergoes warranty repair. 
 

Содержание QS5 B

Страница 1: ...I...

Страница 2: ...P N QSD 501 ENG Rev 3 2012...

Страница 3: ...2 1 2 Screen mode 2 Percentage Value 10 2 1 3 Screen mode 3 Datalogger 11 2 2 Keys in numerical measure modes 11 2 3 BScan graphic measure screen 14 2 4 Keys in BScan graphic measure sceen mode 15 2 5...

Страница 4: ...5 Adjust display contrast 37 3 3 6 Beep activation 38 3 3 7 Introduction screen 38 3 3 8 Owner information 38 3 3 9 Lock configuration options 40 3 3 10 Model upgrade licenses 41 3 3 11 Return to fac...

Страница 5: ...y in a SCAN graphic 59 4 4 5 Send data from a single file 60 4 4 6 Rename a file 60 4 4 7 View file size 60 4 5 Actions over all files 60 4 5 1 Send all files 61 4 5 2 Erase all files 61 4 6 The Datal...

Страница 6: ...IV Tips on how to measure correctly Technical specifications Additional information Unit maintenance QS5 accessories Error messages Our website www demeq com Technical support...

Страница 7: ...e industry to build instruments that are robust precise and easy to operate We are convinced that our products would not be complete without permanent technical and after sales support So in addition...

Страница 8: ...can lead to property damage personal injury or even death Demeq S R L assumes no responsibility as a result of the improper use of our instruments ASTM E797 The user must be trained in ultrasonic tes...

Страница 9: ...t electrical pulses from the unit sending short acoustic waves into the test piece The second crystal then receives the acoustic waves reflected at the end of the test piece The frequency of the acous...

Страница 10: ...ted Calibration of the transducer is also known as zero calibration or delay calibration Page 15 If the unit and transducer are not calibrated or calibrated incorrectly the resulting measurements will...

Страница 11: ...t layers that may result in testing errors The amount of couplant should be kept to a minimum and consistent pressure should be applied on the transducer when measuring Doubling refers to a thickness...

Страница 12: ...controlled instruments always make sure that the operations required for your application are in correct working order Demeq S R L provides a limited warranty for a period of 2 two years on electroni...

Страница 13: ...llumination 2 Move Left key Switch measuring modes normal measurements or Echo 1 Thru Paint or Echo 2 Echo 3 Move Up key Manually store a value Store 4 Move Right key Switch to graphical measure mode...

Страница 14: ...econds Make quick and short touches to activate special functions and features 10 Calibration disk 11 Horizontal scrolling center point lock and unlock keypad on measure screen 12 Vertical scrolling c...

Страница 15: ...igure 1 3 1 and gently push the extraction ribbon upward and slightly towards the right to release the batteries figure 1 3 2 When you install new batteries first insert the positive end of each batte...

Страница 16: ...ce Insert batteries Notes Use new alkaline top brand batteries only Do not mix new and old batteries Always replace both batteries Rechargeable batteries type NiMH can be used but will result in less...

Страница 17: ...l probes you could basically connect any probe to your QS5 Keep in mind that the gain may need to be adjusted when changing probes To connect the probe simply align any of the male connectors located...

Страница 18: ...seconds to shutdown the unit With the unit on making short touches to the will activate special functions described in later chapters of this manual Backlight illumination and contrast options can be...

Страница 19: ...7 Display contrast adjustment To lock the keypad place your finger on the white dot located in the center of the horizontal scrolling bar between the keys Move your finger to the right following the d...

Страница 20: ...8 Chapter 1 Sliding the finger to the left will unlock the keypad Figure 1 9 Unlocking the keypad Important The keypad can only be locked and unlocked in the measuring screens...

Страница 21: ...tch numerical measure screens touch the key Figure 2 1 Measure screen mode 1 1 Material velocity 2 Datalogger mode indicator Page 62 3 Measured value signal in differential measuring mode Page 44 4 Ba...

Страница 22: ...Page 20 12 Maximum measured value 13 Trigger level Page 20 14 Minimum measured value Note Touching the once will reset maximum and minimum values to zero and touching it again will display the measure...

Страница 23: ...cal measure screen modes the following applies in terms of keypad functionality Touch once to switch from Echo 1 to Echo 2 Touch again to switch back to Echo 1 the Echo key is active only in QS5 E and...

Страница 24: ...To select thickness measurement touch To select material velocity touch To select trigger touch To select gain touch Always use the keys to edit the values in any given field and touch to save Trigge...

Страница 25: ...ties Use the cursor keys to scroll the list and touch to select or touch to exit and return to the edit velocity field When a measurement was taken and the velocity is changed a new measurement is aut...

Страница 26: ...Thickness value in the selected unit 5 Icon indicating that a value was stored 6 Locked keypad icon indicator Page 7 7 Inactive calibration disk indicator Page 15 8 Coupling level indicator material c...

Страница 27: ...in out of the graphic Touch for 2 or more seconds to shutdown the unit The QS5 uses a zero delay calibration procedure that is activated by simply coupling the transducer over the calibration disk lo...

Страница 28: ...on procedure simple touch the edge of the disk until an icon appears as shown in Figure 2 1 8 Inactive calibration disk indicator Page 9 While still touching the edge of the disk couple the transducer...

Страница 29: ...es available on the QS5 go to the Ultrasonic menu page 43 and enter the Calibr option Select 2 Points and follow the procedure below for calibration Figure 2 7 One point and two point calibration proc...

Страница 30: ...ch to save and the unit will ask Measure 2nd Pt 5 When a measurement is displayed for the second test piece simple touch Edit to edit the value using the cursor keys so that it matches the second test...

Страница 31: ...e velocity and touch to confirm or touch to cancel Tip Touch the when editing velocity and a screen will appear with the most commonly used materials and their velocities Use the cursor keys to scroll...

Страница 32: ...known thickness value the unit must have already been calibrated for the transducer being used Page 15 The QS5 has two controls Trigger and Gain that have a direct impact on the ultrasonic signal pro...

Страница 33: ...audio device the higher the gain setting the more amplified the echoes will be A low trigger and a high gain are ideal in obtaining good sensitivity but if the trigger is set too low or the gain too...

Страница 34: ...s Important Material defects that are represented by the coupling icons serve only as a warning and should not be interpreted as definitive results The specific area where the possibility of a materia...

Страница 35: ...hermal treatments and test piece defects easier regardless of the measured thickness DAC is activated in the Ultrasonic menu page 47 The higher the energy level reflected from the test piece bottom th...

Страница 36: ...low energy this usually means that it was subject to thermal treatment To confirm or discard this possibility measure the velocity of the test piece Steel that has been thermally treated will have a d...

Страница 37: ...or Echo 2 coating thru paint Switch between Echo modes touching and wait until the window indicating the mode you are in disappears This means that the unit is now set for the Echo mode you selected F...

Страница 38: ...ed and calibration is actually blocked because when operating with multiple echoes the delay in the transducer does not affect the thickness measurement To obtain precise and reliable measurements in...

Страница 39: ...ult in scattering of ultrasonic waves making it impossible to measure Use sufficient coupling gel for stable coupling in order to avoid erroneous or incorrect readings Always use dmq hi damp transduce...

Страница 40: ...ys When you reach the end of the menu and move to the next menu option it becomes circular as shown below Figure 3 1 Example of how a circular menu works To select a menu option touch and to exit and...

Страница 41: ...se the cursor keys on the unit to scroll the virtual keyboard until you find the character you want to use and touch to select Touch to move to the upper case virtual keyboard and to the numbers and s...

Страница 42: ...oard to the most commonly used virtual keyboard keys Each virtual key corresponds to a key on the front panel of the unit as follows Move the cursor to the left Erase the character on which the cursor...

Страница 43: ...ry are explained later on in this manual Touch on Unit in the main menu to open the list of available units Use the keys to scroll the menu Touch to select the unit and touch to save and exit this men...

Страница 44: ...terial condition analyzer detects the presence of a possible defect such as corrosion or pitting Enabling this option will activate the Analyzer page 49 Beep Audible intermittent alarm type Screen Vis...

Страница 45: ...BScan Range to open the menu Touch on High or Low to open the numbers editor where you can set a value using the cursor keys Touch to save and return to the previous menu Touch on Language which is a...

Страница 46: ...the keys To return to the main menu touch Note The information required to obtain model upgrade licenses is included in this option Touch on the Configure option to open the general configuration opt...

Страница 47: ...editor screen Set the date and touch to save and exit Figure 3 12 Time and date editing screens Choose Clock Format to open the menu that allows you to set the time format 12Hs or 24Hs and the date f...

Страница 48: ...rm the change in sensitivity touch If you touch any other key or the counter that appears on your screen reaches 0 0 the sensitivity will return to its previous setting The factory default setting is...

Страница 49: ...keys to set the time and touch to save and exit Touch to exit without making changes Figure 3 15 Auto off time setting screen Use this setting to adjust the screen contrast making it lighter or darker...

Страница 50: ...ted Touch to enable or disable the beep option The introduction screen is the first screen that you would see if this option is enabled after the unit is turned on It includes owner information such a...

Страница 51: ...or change the telephone number Name Set or change the e mail before the Domain Set or change the domain for the e mail after the Edit Pass Allows you to change the password needed to access this menu...

Страница 52: ...nfigured and that the settings cannot be changed Touch on Locks enter your password and then touch again to view the configuration options that can be locked Figure 3 18 Enter password and options loc...

Страница 53: ...purchase Touch on Licenses to view all licenses available for your unit checkmarks indicate active licenses Figure 3 19 Licenses screen To enter the new license number that you purchased from dmq touc...

Страница 54: ...screen where the newly purchased license appears followed by a checkmark Choose Set Default to return to the original factory default general configuration options Touch and a confirmation screen will...

Страница 55: ...loc option to change the material velocity so that it matches the material that will be measured Use the cursor keys to change the velocity and touch to enter To exit without making changes touch Touc...

Страница 56: ...nominal value The modes in which measurements are represented are Absolute the unit displays the real measured value Different the displayed value is the result obtained from calculating Differential...

Страница 57: ...the gain refer to Changing trigger and gain page 20 Touch on Refresh to open the refresh rate options menu the speed in which measurements will be taken Use the keys to scroll menu options and touch...

Страница 58: ...urements Touch on Freq to open the transducer frequency rate options menu Use the keys to scroll menu options and touch to select To exit without making changes touch Figure 3 27 Transducer frequency...

Страница 59: ...ion Even though the coating type option is available for all QS5 models this setting only affects the QS5 E and QS5 DLE models that can operate in Echo 2 mode or thru coatinging Touch on Cal to open t...

Страница 60: ...unit screen even when the transducer is not coupled When hold last is disabled and the transducer is not coupled the unit display will read Touch to enable or disable this option Figure 3 30 Measurin...

Страница 61: ...oupled measuring or not coupled in the air Touch to enable or disable this option Important Material defects that are represented by the coupling icons serve only as a warning and should not be interp...

Страница 62: ...m option and touch again to disable Figure 3 31 Normal and Nums Zoom numerical measure screens When AutoMain is enabled the unit continuously monitors the transducer so that when the transducer is cou...

Страница 63: ...gher excitation or tension levels mean that more energy is applied to the emissions crystal in the transducer making it easier to measure in high attenuation and large or thick materials When measurin...

Страница 64: ...iginal factory default ultrasonic configuration settings Touch and a confirmation screen will appear Touch to confirm and return to the previous menu or touch to exit without making changes Figure 3 2...

Страница 65: ...columns identified with consecutive letters A B AA AB that store an N number of values or measurements batch Each value is identified with a column letter and a row number Figure 4 1 How data is orga...

Страница 66: ...navigate the list of files in the unit Figure 4 3 Creating a file Select a file that appears as Empty available file and touch to name the file with up to 10 alphanumeric characters After you enter a...

Страница 67: ...tored In closed files values can only be viewed Whenever you create a new file and another file is already open a warning screen will ask if you want to close the last file Touch to confirm that you w...

Страница 68: ...ogram that includes that same value as well as the values included in the foregoing cells within that column Touch to exit and return to the grid Figure 4 7 Histogram representation High and low alarm...

Страница 69: ...the column letter using the cursor keys so that when you touch the grid will position itself on that column Cell This is a combination of column and row so that you can go to a specific cell after yo...

Страница 70: ...ues in the batch based on the high and low alarm settings Stats View statistical information for the batch including Min Max Range and Mean values Stats View the standard deviation and the percentage...

Страница 71: ...scan Figure 4 10 Quick access menu in a scan graphic Goto Access a specific position within the scan by entering its location List List Opens the list of measured values in the scan use the to scroll...

Страница 72: ...inal or to a printer using an RS232 connection This option does not work in USB mode Touch on Rename to open the text editor that allows you to change the file name Touch on Size to view the number of...

Страница 73: ...manently deletes all files stored in the unit memory and recovers 100 of the memory capacity Before files are deleted a screen will be displayed asking you to confirm or to cancel this action Touch to...

Страница 74: ...letters X Datalogger is disabled no open file M Manual capture mode U Single auto capture mode C Continuous auto capture mode S SCAN block capture mode 2 Storage type Grid or SCAN If measurements are...

Страница 75: ...In each quick memory menu screen two options are displayed at the bottom of each screen To access these options use the keys The key maintains its normal functionality and the key is used to switch qu...

Страница 76: ...cable that you are using is properly connected to both the unit and the PC and click on Connect in DataCenter When a successful connection is established the files in your unit memory will appear in...

Страница 77: ...first two options in the configure Datalogger menu are Mode and Send which allow you to select how the unit will communicate with a PC or a printer Figure 4 18 Configure communications options Touch o...

Страница 78: ...l 38400 8 N 1 Print Using an RS232 cable and printer the unit sends data in an optimal format for mini printers of 40 columns 9600 8 N 1 Notes The print option can only be used with RS232 printers Fil...

Страница 79: ...to the Store Every N number of values that can be set on the Advanced Datalogger menu options Page 67 Touch on Histogram to set the number of values for each batch when the Fix Batch option is enable...

Страница 80: ...in the Datalogger when Continuous capture mode is enabled Page 66 When you enable history the Datalogger will register the unit settings for each measurement that is stored Information such as gain t...

Страница 81: ...h to select and exit Touch to exit without making changes Figure 4 21 Record date and time in the Datalogger Off The Datalogger does not record date and time Date Each time a new batch is opened the D...

Страница 82: ...ated in the front of the unit particularly when changing transducers Have a reference test piece of the same material that you will be measuring and know the velocity of the material or its thickness...

Страница 83: ...99 99 mm 0 1 mm from 100 0 mm and above 0 001 in from 0 040 to 9 999 0 01 in from 10 00 in and above Material velocity 100 to 19999 m S 3 937 to 787 3 in ms Calibration Auto 1 Point and 2 Point Alarms...

Страница 84: ...n and contrast adjustment Keypad Touch sense with no mechanical parts and sensitivity adjustment Battery life 100 hours with 2 each type AA batteries Operating temp 10 C to 50 C Enclosure High impact...

Страница 85: ...bstances Do not clean the unit with solvents Do not leave the unit display exposed to direct solar light for prolonged periods of time as this could damage the display Remove the batteries if the unit...

Страница 86: ...u Paint QSS 701 7Mhz transducer 5 mm diameter QSR 161 6 step calibration block mm QSR 141 4 step calibration block in QSG 001 Coupling gel QSL 102 QS5 B to QS5 DL upgrade license QSL 301 QS5 E to QS5...

Страница 87: ...System error message Error 1 Internal Error Cause Internal Error Solutions Shutdown the unit wait a few seconds and power back on Contact dmq Error 2 Attempt to store a value over an existing value Ca...

Страница 88: ...information New accessories To download software updates to your QS5 you must have dmq DataCenter installed on your PC To download the latest updates for your unit refer to www demeq com Download html...

Страница 89: ...77 Capitulo 4 P N QSD 501 ENG Rev 3 2012 dmq...

Отзывы: