Exit Programming
Remove the jumper from the PROGRAM header to exit the 738I programming mode. Place
the jumper over one pin for future use. Remove the Model 330 cable and the 32-character
keypad from PROG header. After exiting programming mode, all zone states report to the
panel as NORMAL. Test and verify all zones for proper communication.
738I LED Operation
The green LED on the 738I Module indicates data transmission to the panel.
On:
There are no transmitters programmed.
Off:
The 738I is not being programmed, or the 738I is not responding to the panel.
Flashes: The 738I is transmitting data to the panel, or it is being programmed.