VISTA Panel Compatibility

Panel Type

ECP

Remote  

User Management

Remote  

Arming/Disarming

Remote  

Zone Status

Compatible with 

Compass

VISTA-10SE

Rev 15 or higher

No

No

No

No

VISTA-10P

Yes

Yes

Yes

Yes

Firmware version 

2.0 or higher

VISTA-15

Yes

No

No

No

No

VISTA-15P

Yes

Yes

Yes

Yes

Firmware version 

5.2 or higher

VISTA-20SE

Rev 12 or higher

No

No

No

No

VISTA-20P

Yes

Yes

Yes

Yes

Firmware version 

5.2 or higher

VISTA-20PI

Yes

Yes

Yes

Yes

Firmware version 

5.0 or higher

VISTA-21iP

Yes

Yes

Yes

Yes

Yes 

VISTA-21iPLTE

Yes

Yes

Yes

Yes

Yes

Note:

 Vista 32, 40, 50, 128, 250 are not compatible with ECP Virtual Keypad and eSuite.

Содержание Com Series

Страница 1: ...HOW TO GUIDE ECP PASSTHRU...

Страница 2: ...tep 3 Program the Vista Keypad 4 Step 4 Configure ECP Settings 4 Remotely Dealer Admin 4 Locally Keypad 5 Troubleshooting 5 Step 5 Remote Programming 6 Set up Remote Link 6 Add the VISTA Panel in Comp...

Страница 3: ...ttings remotely or locally Required Materials The following software and hardware components are required to perform system takeovers Compatible Honeywell VISTA panel refer to VISTA Panel Compatibilit...

Страница 4: ...to the ECP Bus of a VISTA panel See Table 1 and Figure 2 for the necessary wiring connections Caution Remove all AC and battery power from the panels before wiring 1 Attach the antenna to the SMA con...

Страница 5: ...1 CABLE 1 2 3 4 5 6 7 8 OUT 17 12 AUX GND OUT 18 VISTA 20P ONLY VISTA 20P From DC From DC From Z4 From Z4 To Data In 6 To Data Out 7 To Negative 4 To Positive 5 DC Z1 Z2 Z3 G T R Z4 O1 O2 CellCom or D...

Страница 6: ...emotely with Dealer Admin or locally with a programming keypad Remote programming requires communicators with firmware Version 212 or higher Local configuration requires communicators with firmware Ve...

Страница 7: ...to ECP SETUP and press any select key or area 10 At ECP SETUP VISTA 128 If the panel is a VISTA 128 select YES Otherwise select NO 11 At INST CODE enter the ECP panel installer code and press CMD 12 A...

Страница 8: ...you already have a basic communicator account added to your Remote Link accounts To enable ECP Passthru for that account complete the following steps 1 Right click Remote Link and select Run as admini...

Страница 9: ...Compass 2 In the lower right corner of the Customers page select Add The Customer Detail window opens 3 In Subscriber Data enter a Receiver number and Account number 4 In the Panel Data section selec...

Страница 10: ...the account that you created in the previous section 2 The Panel Editor opens Go to Tools Communications 3 Go to File Communication Settings 4 Select TCPIP Port Settings 5 To ensure that Compass uses...

Страница 11: ...cation window press Connect 2 A dialog pops up to notify you that communication settings must be configured Press OK 3 Select Enable TCP IP 4 In the TCPIP Port dropdown select the appropriate TCP IP p...

Страница 12: ...rs to manage their systems remotely including arming disarming viewing zone status bypassing zones view history manage users and more To use Virtual Keypad for remote management the configuration must...

Страница 13: ...sarming Remote Zone Status Compatible with Compass VISTA 10SE Rev 15 or higher No No No No VISTA 10P Yes Yes Yes Yes Firmware version 2 0 or higher VISTA 15 Yes No No No No VISTA 15P Yes Yes Yes Yes F...

Отзывы: