7000 Series Installation and Programming Guide   |   Digital Monitoring Products  

 

 

 

 

   10

PROGRAM THE KEYPAD

Refer to the appropriate panel programming guide as needed. Operation for some programming options is restricted 
to the appropriate model. To access the Keypad Options menu:

Hold down the back arrow and 

CMD

 keys for two seconds. At 

SET

 

BRIGHTNESS

, enter 

3577

 (INST) and press 

CMD

.

The display changes to 

KPD

 

OPT

  

KPD

 

DIAG

  and 

STOP

.

Keypad Options

To program keypad options, press the select key under 

KPD OPT

. When finished 

programming, press 

STOP

 to save all programming.

Current Keypad Address

Set the current keypad address from 01 to 08 for XT30/XT50 or XR150 Series panels, 
or 01 to 16 for XR550 Series panels. The default address is 

01

. To change the current 

address, press any select key and enter the new address and press 

CMD

. Do not enter 

a leading zero for addresses 01 to 09.

Keypad Mode

Keypads with programmed zones must be supervised and cannot share an address 
with other keypads. Unsupervised keypads can operate together sharing the same 
address, but cannot be used when Device Fail Output has a programmed value other 
than zero. To select a keypad mode, press the select key under 

SUP

 or 

UNSUP

. An 

asterisk appears next to the selected option.

Default Keypad Message

Enter a custom message of up to 16 characters to appear at the top of the keypad 
display. Press any select key, enter a new message, and press 

CMD

.

Arm Panic Keys

Use this option to enable or disable the panic keys. Press the select key under the 
desired name: 

PN

 (panic), 

EM

 (emergency), and 

FI

 (fire). Press the select key again to 

disable the panic option. Once the panic option is enabled, an asterisk displays next 
to the selected option(s).

7/0 Panic

Press the fourth select key to choose 

YES

, configuring the 7 and 0 keys as two-button 

panic keys. Select 

NO

 to disable the option. Default is 

NO

.

Activate Zone 2 Bypass (7073/A, 7173 only)

Select 

YES

 to activate the zone 2 bypass operation. Selecting 

NO

 allows standard 

zone operation on zone 2. The default is 

NO

.

If the door being released by the keypad is protected (contact installed), a 
programmable bypass entry/exit timer can be provided by connecting its contact 
wiring to the keypad zone 2. When the onboard Form C relay activates and the user 
opens the door connected to zone 2, the zone is delayed for the number of seconds 
programmed in 

ZONE 2 BYPASS

 time allowing the user to enter/exit during an armed 

period.

KPD

 KPD

OPT

 DIAG 

STOP

CURRENT KEYPAD

ADDRESS: 1

KEYPAD MODE:

*SUP    

UNSUP

DEFAULT KPD MSG:

ARM PANIC KEYS:

*PN     EM     *FI

7/0 PANIC

ENABLE: 

NO

ACTIVATE ZONE 2

BYPASS? 

NO

Содержание Aqualite 7060A

Страница 1: ...INSTALLATION AND PROGRAMMING GUIDE 7000 Series Thinline and Aqualite Keypad ...

Страница 2: ...onic Lock 5 Wire the 333 Suppressor 5 Program the Panel 7 Program the Keypad 8 Keypad Options 8 Custom Card Format 10 Additional Programming 13 Test the Keypad 14 End User Training 15 Keypad Arming and Disarming 15 Keypad Access Control 16 Keypad Entry Delay 16 Reference 17 ULC Commercial Burglary 17 Keypad Bus Wiring Specifications 17 Compatibility 17 Public Card Formats 17 Readers and Credential...

Страница 3: ...le Class B Style A supervised power limited protection zones that can be programmed for a variety of burglary and access control applications Models 7063 A 7073 A 7163 and 7173 Provides a built in proximity card reader designed to read 125KHz proximity credentials Models 7073 A and 7173 Provides a door strike relay and allows Wiegand input from external card readers What s Included One 7000 Series...

Страница 4: ...king power connections Each keypad model has specific wiring assignments All zones are supervised and suitable for residential burglary or fire applications The maximum zone line impedance is 100 Ohms The ground fault is detected at 1420 Ohms or less See Keypad Bus Wiring Specifications in this document for additional wiring information Use 1k Ohm EOL resistors DMP Model 311 on keypad zones 1 4 1 ...

Страница 5: ...Receive Data from Panel Gray Door Strike C Yellow Send Data from Panel Orange Door Strike NO Red Power from Panel White Brown Zone 1 Black Ground to Reader White Red Zone 2 Red Power to Reader White Orange Zone 3 White Reader Data 1 White Yellow Zone 4 White Green Reader Data 0 Required connections Additional Power Supply If the current draw for all keypads exceeds the panel output provide additio...

Страница 6: ...able See Figure 2 Violet Door Strike Normally Closed Gray Door Strike Common Orange Door Strike Normally Open White Green Reader Data 0 White Reader Data 1 Black Ground Green Receive Data Yellow Send Data Red Keypad Power White Yellow Zone 4 1k Ω White Orange Zone 3 Request to Exit option 1k Ω White Red Zone 2 Door Contact option 1k Ω White Brown Zone 1 7 0 Panic option 1k Ω External Card Reader T...

Страница 7: ...trike relay activates for five seconds During this time the access door connected to Zone 2 must be opened to start the programmed entry exit timer and Zone Bypass if programmed and used The five second door strike is panel programmable when the keypad is used on an XR150 XR550 Series panel Zone 2 Door Contact with Bypass If the door being released by the 7073 A and 7173 keypad is protected you ca...

Страница 8: ...nic Keys Power LED Armed LED Proximity Credential Reader and Backlit Logo 32 Character Display Select Keys Command Key Back Arrow Key Figure 6 7000 Series LCD Keypad 1 2 3 4 5 6 7 8 9 0 A C B D F E G I H J L K V X W S U T P R Q M O N YZ BAC K CMD ABC SECURITY FRI 2 52 PM POWER ARMED Command Key Select Keys 32 Character Display Power LED Armed LED Back Arrow Key Proximity Credential Reader and Back...

Страница 9: ...Select Key for the character and press that select key on the keypad Press that select key again for the lowercase letter Latin characters only 4 When the desired character displays on the keypad return to step 1 to enter another character or press CMD if finished Table 1 Latin Characters NUMBER SELECT KEY 1 2 3 4 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 P Q R 7 S T U 8 V W X 9 Y Z Space _ 0 NUMB...

Страница 10: ... level power and armed LEDs the keyboard and the logo backlighting At SET BRIGHTNESS use the left select key to decrease the brightness and the right select key to increase the brightness If the brightness level is lowered it reverts to maximum intensity whenever a key is pressed If no keys are pressed and the speaker has not sounded for 30 seconds the user selected brightness level restores Inter...

Страница 11: ...then press a select key to enter the setup menu Device Number Set the keypad address from 1 8 for XT30 XT50 and XR150 Series panels or 1 16 for XR550 Series panels Device Name Enter the name for the device Device Type For use as a standard keypad select KPD For use as an access control keypad press any select key then select DOOR Communication Type Ensure the COMM TYPE is set to KPD Keypad Bus Con...

Страница 12: ...r UNSUP An asterisk appears next to the selected option Default Keypad Message Enter a custom message of up to 16 characters to appear at the top of the keypad display Press any select key enter a new message and press CMD Arm Panic Keys Use this option to enable or disable the panic keys Press the select key under the desired name PN panic EM emergency and FI fire Press the select key again to di...

Страница 13: ...zone 3 Default is NO When zone 3 shorts the onboard Form C relay activates for the programmed number of seconds During this time the user can open the protected door to start the programmed bypass entry exit timer If the door is not opened within the time programmed in the Zone 3 REX Strike Time the relay restores the door to its locked state Zone 3 REX Strike Time 7073 A 7173 Enter the number of ...

Страница 14: ...s for some publicly available card formats that can be used with the keypad Other private or custom formats may also be compatible Please contact the credential supplier or manufacturer for the bit structure Note If you select slot 1 and you are upgrading from XR panel version 182 or earlier FORMAT NAME will automatically be named SINGLE CARD FORMAT and WIEGAND CODE LENGTH will default to 45 Forma...

Страница 15: ...lt is NO In addition to user code verification door access is only granted when any one site code programmed at the SITE CODE ENTRY option matches the site code received in the Wiegand string Site Code Display You can program up to eight 8 digit site codes The site code range is 0 16 777 214 In the keypad display enter site code 1 and press CMD The display will ask for site code 2 followed by site...

Страница 16: ...mmed site code Refer to Require Site Code for more information Press the third select key or area to choose ANY Any Wiegand Read Access is granted when any Wiegand string is received Press the fourth select key or area to choose ON Relay Always On The relay is always on Press CMD to display additional actions Press the first select key or area to choose LAST Keep Last State The relay remains in th...

Страница 17: ...ader can be connected and will be compatible with 13 56 MHz proximity credentials For a list of publicly supported card formats see Public Card Formats Note Some proximity credentials are not compatible with DMP proximity keypads Test the intended proximity credentials with the application before installation DMP does not guarantee compatibility with credentials not purchased from DMP Program a Cr...

Страница 18: ...SS KEY TO TEST This option tests each key on the keyboard to ensure it is operating properly Press and hold each key for two seconds The key number being held appears in the display Verify the correct number displays before testing the next key Zone Test 7070 7073 A 7170 7173 This option allows the keypads to display the current electrical status of the four protection zones The status is shown as...

Страница 19: ...rred option 3 The keypad displays ENTER CODE The user presents their card to the reader Once validated by the system all areas assigned to that code arm or disarm automatically and the 7073 A and 7173 keypad door strike relay activates See Figure 9 ABC SECURITY ARM DISARM ABC SECURITY ENTER CODE ABC SECURITY ALL NO YES Select NO to arm or disarm individual areas Select YES or simply wait to automa...

Страница 20: ...e System disarms the area and activates the Door Strike Relay ABC SECURITY ENTER CODE Figure 12 Present Access Card ABC SECURITY MON 10 20 AM While the keypad displays the Status List present your access card Typically the relay activates for 5 seconds during which time you can open the door Once you open the door you have 40 seconds to exit and close the door before the Zone 2 Bypass expires Figu...

Страница 21: ...dless of the wire gauge This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2 500 ft As wire distance from the panel increases DC voltage on the wire decreases Maximum number of AX Bus LX Bus devices per 2 500 ft circuit is 40 Maximum voltage drop between the panel or auxiliary power supply and any device is 2 VDC If the voltage at any d...

Страница 22: ...455 ProxPro II Proximity Reader TL 5395 ThinLine II Proximity Reader SR3 Bluetooth and Proximity Reader 125 kHz PROXIMITY CREDENTIALS PSC 1 Standard Light Proximity Card PSK 3 Proximity Key Ring Tag PSM 2P ISO Imageable Proximity Card 1306 Prox Patch 1326 Proxcard II Card 1346 ProxKey III Access Device 1351 ProxPass 1386 IsoProx II Card BLUETOOTH MOBILE CREDENTIALS Mobile Credentials SR3 13 56 MHz...

Страница 23: ...CC Part 15 RFID Reader FCC ID CCKPC0086 Thinline and Aqualite Industry Canada ID 5251A PC0086 Thinline and Aqualite New York City FDNY Only for keypads with zones Underwriters Laboratory UL Listed ANSI UL 294 Access Control System Units Level I Destructive Attack and Line Security Level IV Endurance and Standby Power ANSI UL 365 Police Connected Burglar ANSI UL 609 Local Burglar ANSI UL 1023 House...

Страница 24: ...of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada Information This device complies with Industry Canada License exempt RSS standard s O...

Отзывы: