9862INT Series Installation and Programming Guide
24
Number of User Code Digits
The keypad recognizes user codes from 4-10 digits long.
Press any top row select key or area to enter a user code
digit length. This number must match the user code number
length being programmed in the panel. The device will
recommend a number of user code digits based on the user
code length. Default is
5
.
All bits are read and converted into a decimal number string.
The number string is left padded with 0 (zero) if needed for
long user code lengths.
Example:
# decoded
1234567
10
digits
0001234567
4
digits
4567
No Communication with Panel
Define the relay action when communication with the panel
has not occurred for 5 seconds:
OFF
,
SITE
,
ANY
,
ON
, or
LAST
. Default is
OFF
. Press any select key or area to change
the default relay action:
NO OF USER CODE
DIGITS:
5
NO COMM WITH PNL
OFF