Power the Keypad
Primary DC Power Supply
Locate the keypad near a wall outlet to allow connection of the Model 371-500
plug-in DC power supply. See Figure 6 for a diagram of the DC power supply
connector. In addition to powering the keypad, the power supply also charges the
internal back-up battery. The plug-in power supply includes a six foot cord. The
cord can be lengthened but should be located within 100 feet of the keypad using
22 AWG wire.
Caution
: Observe polarity when extending
the power supply cord.
When the power supply connector is plugged
into the keypad, the internal battery is
automatically connected. The keypad can
operate from battery only as long as the power
supply connector is plugged into the keypad.
Standby Battery
The keypad rechargeable battery provides 24 hours of backup battery power
when primary DC power is unavailable. It is shipped already installed inside the
keypad. The battery is intended for backup power only and not to operate the
keypad on a daily basis. If the battery is low, or not plugged into the internal
battery connector, a low battery condition is indicated by the panel when the
battery falls below 3.62 VDC. To restore the keypad from a low battery state, the
voltage must be above 3.62 VDC.
3
Black (-)
Black/White
Stripe (+)
Figure 6: DC Power Supply
Connector
Содержание 9000 Series
Страница 1: ...INSTALLATION AND PROGRAMMING GUIDE 9000 Series Wireless Keypads ...
Страница 2: ......
Страница 4: ...Compliance Specifications 36 Certifications 37 FCC Information 38 Industry Canada Information 39 ...
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ...LT 1107 20014 1 04 2019 Digital Monitoring Products Inc ...