Digital Monitoring Products

791/793 Keypad Installation Sheet

3

End-User Options

The 791 and 793 Easy Entry™ Keypads provide three adjustments to the keypad that can be made by the end-user

through a User Options Menu.  The user can also view the keypad model number and address in User Options.  Below

is a description of the adjustments and instructions on their operation.
To access the 

User Options

 portion of the keypad, press and hold the Back Arrow and COMMAND keys for two

seconds.  The keypad display changes to 

SET BRIGHTNESS

.  Use the COMMAND key to display the next Option or press

the Back Arrow key to exit the 

User Options

 function.

Backlighting brightness

Set the brightness level of the keypad’s LCD Display, AC LED, and the Green keyboard backlighting.  Use the left

Select key to lower the keypad brightness and the right Select key to raise the brightness.  If the brightness level is

lowered, it reverts to maximum intensity whenever a key is pressed.  If no keys have been pressed, and the speaker

has not sounded for 30 seconds, the user-selected brightness level is restored.

Internal speaker tone

Set the tone of the keypad’s internal speaker.  At the 

SET TONE

 display, use the left Select key to lower the tone and

the right Select key to raise the tone.

Volume Level

Set the volume level of the keypad’s internal speaker for key presses and prewarn conditions.  During alarm and

trouble conditions, the volume is always at maximum level.  Use the left Select key to decrease the keypad volume

and the right Select key to increase the volume.  Press the COMMAND key to display the Model Number.

Model Number

The LCD displays the model number, and the version and date of the keypad’s firmware.  The user cannot change this

information in 

User Options

.

Keypad Address

The LCD displays the current keypad address.  While in User Options, the user cannot change the keypad address.

Press the Back Arrow key to exit the 

User Options

 function.

Installer Options Menu

The Easy Entry keypads also contain a 

Keypad

 

Options

 and 

Keypad Diagnostic

 program that allows installers and

service technicians to configure and test the keypad operation.
You can only access the 

Installer Options Menu 

through the User Options function.  After holding down the Back

Arrow and COMMAND keys for a few seconds and getting the 

SET BRIGHTNESS

 display, enter the code 3577 (INST) and

press COMMAND.  The display now changes to 

KPD OPT

 (keypad options) 

KPD DIAG

 (keypad diagnostics) and 

STOP

.

Keypad Options (KPD OPT)

This option allows you to set the keypad address, select supervised or unsupervised mode, change the default keypad

message, individually arm the 2-button Panic keys, and select Soft-Shunt, Request-to-Exit, and 4-digit entry cards.

To enter, press the left Select key under 

KPD OPT

.  The display changes to 

CURRENT KEYPAD ADDRESS:  # #

.

Set the CURRENT KEYPAD ADDRESS:

You can set the keypad address from 01 to 05 with the XRSuper6 and XR20, from 01 to 09 with the XR40, XR200, and

XR2400F, and 01 to 16 with the XR200-485.  The factory default address is set at 01.  To change the current address,

press any Select key and then enter the new address using the appropriate number keys on the keyboard.  It is not

necessary to enter a leading zero for addresses 01 to 09.

Select Supervised or Unsupervised KEYPAD MODE:

You can configure the keypad for either supervised or unsupervised operation.  Supervise keypads that have zones
connected to them.  Supervised keypads cannot share addresses with other keypads.  To enhance the supervision
feature, assign an output to the Device Fail Output in the panel’s programming and connect a device to the
corresponding output that will trip when the keypad fails.  This provides notification at the central station and the
site.  The other keypads will not display the device fail.
Unsupervised keypads 

can

 operate with other unsupervised keypads sharing the same address.  Zones cannot be used

on unsupervised keypads.  To change the current setting, press the Select key under 

SUP

 or 

UNSUP. 

 An asterisk

appears next to the selected option.

Note:

 An unsupervised address cannot be programmed for Device Fail Output.

Содержание 791 Easy Entry

Страница 1: ...the gauge of wire This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2 500 feet 3 Maximum number of devices per 2 500 feet circuit is 40 Note Each panel allows a specific number of supervised keypads Additional keypads can be added in the unsupervised mode Refer to the panel s installation guide for the specific number of supervised key...

Страница 2: ...r magnetic lock Door Contact Zone with Soft Shunt If the door being released by the keypad is protected you can provide a 40 second shunt by connecting its contact to zone 2 White Red pair on the keypad and enabling the Soft Shunt feature See ACTIVATE ZONE 2 SHUNT on page 4 and Door Strike Relay Operation on page 5 Once the door strike relay is activated the user has 5 seconds to open the door con...

Страница 3: ...tions Menu The Easy Entry keypads also contain a Keypad Options and Keypad Diagnostic program that allows installers and service technicians to configure and test the keypad operation You can only access the Installer Options Menu through the User Options function After holding down the Back Arrow and COMMAND keys for a few seconds and getting the SET BRIGHTNESS display enter the code 3577 INST an...

Страница 4: ...Soft Shunt for door contacts Zone 2 must be programmed into the panel ACTIVATE ZONE 3 EXIT NO YES Select YES to enable the Request to Exit feature on zone 3 Zone 3 is included in panel programming by default 4 DIGIT ENTRY CARDS NO YES Select YES to enable the 4 Digit Entry Cards function on Home Away or other systems that require 4 digit user codes ALL NO YES DELAY 2 Select the number of seconds t...

Страница 5: ...oor Strike relay activates for five seconds Note The length of the 5 second delay is programmable when the keypad is used on an XR200 485 During this time the access door connected to zone 2 must be opened to start the 40 second entry exit timer and zone soft shunt See the timeline shown below 1 5 5 Second Strike Access door is opened 40 Second Soft Shunt and entry exit timer 40 Seconds At 30 seco...

Страница 6: ...s the Door Strike relay Using the access reader for user menu access You can also use a card reader to access the User Menu When the MENU NO YES display is shown present your proximity card to the reader Compatible Access Devices The 791 and 793 Keypads are compatible with the following readers and access keypads I N T R U S I O N F I R E A C C E S S N E T W O R K S 2500 North Partnership Boulevar...

Отзывы: