Digital Monitoring Products
791/793 Keypad Installation Sheet
3
End-User Options
The 791 and 793 Easy Entry™ Keypads provide three adjustments to the keypad that can be made by the end-user
through a User Options Menu. The user can also view the keypad model number and address in User Options. Below
is a description of the adjustments and instructions on their operation.
To access the
User Options
portion of the keypad, press and hold the Back Arrow and COMMAND keys for two
seconds. The keypad display changes to
SET BRIGHTNESS
. Use the COMMAND key to display the next Option or press
the Back Arrow key to exit the
User Options
function.
Backlighting brightness
Set the brightness level of the keypad’s LCD Display, AC LED, and the Green keyboard backlighting. Use the left
Select key to lower the keypad brightness and the right Select key to raise the brightness. If the brightness level is
lowered, it reverts to maximum intensity whenever a key is pressed. If no keys have been pressed, and the speaker
has not sounded for 30 seconds, the user-selected brightness level is restored.
Internal speaker tone
Set the tone of the keypad’s internal speaker. At the
SET TONE
display, use the left Select key to lower the tone and
the right Select key to raise the tone.
Volume Level
Set the volume level of the keypad’s internal speaker for key presses and prewarn conditions. During alarm and
trouble conditions, the volume is always at maximum level. Use the left Select key to decrease the keypad volume
and the right Select key to increase the volume. Press the COMMAND key to display the Model Number.
Model Number
The LCD displays the model number, and the version and date of the keypad’s firmware. The user cannot change this
information in
User Options
.
Keypad Address
The LCD displays the current keypad address. While in User Options, the user cannot change the keypad address.
Press the Back Arrow key to exit the
User Options
function.
Installer Options Menu
The Easy Entry keypads also contain a
Keypad
Options
and
Keypad Diagnostic
program that allows installers and
service technicians to configure and test the keypad operation.
You can only access the
Installer Options Menu
through the User Options function. After holding down the Back
Arrow and COMMAND keys for a few seconds and getting the
SET BRIGHTNESS
display, enter the code 3577 (INST) and
press COMMAND. The display now changes to
KPD OPT
(keypad options)
KPD DIAG
(keypad diagnostics) and
STOP
.
Keypad Options (KPD OPT)
This option allows you to set the keypad address, select supervised or unsupervised mode, change the default keypad
message, individually arm the 2-button Panic keys, and select Soft-Shunt, Request-to-Exit, and 4-digit entry cards.
To enter, press the left Select key under
KPD OPT
. The display changes to
CURRENT KEYPAD ADDRESS: # #
.
Set the CURRENT KEYPAD ADDRESS:
You can set the keypad address from 01 to 05 with the XRSuper6 and XR20, from 01 to 09 with the XR40, XR200, and
XR2400F, and 01 to 16 with the XR200-485. The factory default address is set at 01. To change the current address,
press any Select key and then enter the new address using the appropriate number keys on the keyboard. It is not
necessary to enter a leading zero for addresses 01 to 09.
Select Supervised or Unsupervised KEYPAD MODE:
You can configure the keypad for either supervised or unsupervised operation. Supervise keypads that have zones
connected to them. Supervised keypads cannot share addresses with other keypads. To enhance the supervision
feature, assign an output to the Device Fail Output in the panel’s programming and connect a device to the
corresponding output that will trip when the keypad fails. This provides notification at the central station and the
site. The other keypads will not display the device fail.
Unsupervised keypads
can
operate with other unsupervised keypads sharing the same address. Zones cannot be used
on unsupervised keypads. To change the current setting, press the Select key under
SUP
or
UNSUP.
An asterisk
appears next to the selected option.
Note:
An unsupervised address cannot be programmed for Device Fail Output.