24
734INT Installation and Programming Guide | Digital Monitoring Products, Inc.
Zone 3 REX Strike Time
Enter the number of REX seconds to elapse. The range
is 5 to 250 seconds. Press any select key or area to enter the
number of seconds. The default is
5
seconds.
Activate Onboard Speaker
Select
YES
to enable the onboard piezo for local
annunciation, such as alarm and trouble annunciations. Select
NO
to turn the speaker off for all operations. This does not
affect remote annunciator open collector (RA) operation. The
default is
NO
.
Card Formats
Select
DMP
to allow credentials that use a 26 ‑ 45 bit data
string. The menu advances to “Require Site Code”.
Select
CUSTOM
to disable DMP format and program slots 1‑8
as needed. The menu advances to “Card Format Number”.
Select
ANY
to allow all card reads to activate the door strike
relay. The door strike relay is activated for the length of time
programmed in
ZN 3 REX TIME
. No user code information is
sent to the panel. The menu advances to “No Communication
with Panel”.
The default card format is
DMP
.
ACTIVATE ONBOARD
SPEAKER?
NO
YES
CARD FORMATS
DMP
CUSTOM ANY
ZN 3 REX STRIKE
TIME:
5