691 Installation Guide
Digital Monitoring Products
3
Installer Options Menu
All keypads provide Keypad Option and Keypad Diagnostic menus to allow installing and service technicians to configure
and test keypad operation.
Accessing Installer Options
Access the Installer Options Menu through the User Options function. Hold down the Back Arrow and COMMAND keys for
two seconds to display SET BRIGHTNESS. Enter the code 3577 (INST) and press COMMAND. The display changes to KPD OPT
(keypad options), KPD DIAG (keypad diagnostics), and STOP.
The Keypad Options menu allows you to set options for keypad operation.
Note: All programming options display on all keypads, however,
ONLY
the programming options listed below are applicable
and operational. Press the command key to advance past any option that does not apply.
Programming Keypad Options
Kpd Kpd
Opt diag
StOp
Keypad Options (KPD OPT)
To program keypad options, press the left Select key under KPD OPT.
CUrrent Keypad
addreSS:
01
Keypad Address
Set the keypad address from 01 to 08 with the XT30/XT50, or XR100 Series and 01 to 16 with
the XR500 Series. The factory default address is set at 01. To change the current address,
press any Select key and enter the new address. It is not necessary to enter a leading zero
for addresses 01 to 09.
Keypad MOde:
*SUp
UnSUp
Keypad Mode
Configur
e the keypad for either Supervised or Unsupervised operation. Keypads with zones
connected to them must be supervised and cannot share addresses with other keypads.
Unsupervised keypads can operate with other unsupervised keypads sharing the same
address. Zones cannot be used on unsupervised keypads. To change the current setting,
press the Select key under SUP or UNSUP. An asterisk appears next to the selected option.
Note: Unsupervised addresses cannot be used when Device Fail Output has a programmed
value other than zero.
deFaULt Keypad
MSg:
Default Keypad Message
Enter a custom message of up to 16 characters to appear on the keypad display top line
whenever that line is not used for any other purpose. Press any Select key to clear the
current message and enter a new custom display.
arM paniC KeyS:
*pn *eM *Fi
Arm Panic Keys
Use this option to configure the top row Select keys as 2-button Panic keys. To enable
or disable a Panic, press the Select key under the appropriate display: PN (Panic), EM
(Emergency), and FI (Fire). Once the panic is enabled, an asterisk displays next to the
description. Refer to the Panic Key Options section earlier in this document.
7/0 paniC
enabLe: nO yeS
7/0 Panic
Select YES to configure the 7 and 0 keys as a 2-button Panic keys. To disable the option,
select NO. Default is NO. Refer to the Panic Key Options section earlier in this document.
Accessing Keypad Diagnostics
If necessary, refer to Access the Installer Menu earlier in this document.
Kpd Kpd
Opt diag
StOp
Keypad Diagnostics (KPD DIAG)
The Keypad Diagnostic option allows you to check the display segments, keyboard
backlighting and test individual keys.
Press the Select key under KPD DIAG. The keypad lights all display segments. In
approximately one second the display backlighting changes to Green. The keypad alternates
between these two states for approximately two minutes. Press COMMAND at any time to
begin testing individual keys.
preSS Key tO
teSt
Test Individual Keys
The display changes to PRESS KEY TO TEST. This option tests each key on the keyboard to
ensure it is operating properly. Press and hold each key for about two seconds. The key
number being held appears in the display. Verify the correct number displays before testing
the next key.
Exiting the Installer Options
When done, press the COMMAND key once to return to the Installer Options screen. Press the Select key under STOP to exit
the Installer Options function.