Three System Types
continued
Factory Programmed areas
The Area Arming, All/Perimeter, and Home/Away modes each contain factory programmed areas.
Area Arming
All/Perimeter - Home/Away
1- Office (includes the Front Door)
1- Perimeter (includes the Front Door)
2- Warehouse
2- Interior
3- Shipping
4- Sales
Front Door Loop
Pressing the
second left select key while the Office or Perimeter area is armed simulates a front door loop
fault and starts the entry delay. After 15 seconds, the 532XR simulates a front door alarm. Entering a valid
user code disarms the areas and clears the alarm display.
In the Home/Away mode, if you select instant arming during the exit delay, pressing the front door loop key
initiates the alarm but you must enter your disarm code to view the alarm display.
Default User codes
When using the 532XR in Area Arming or All/Perimeter modes, the user code consists of 9 + 9 +
COMMAND
.
When using the 532XR in the Home/Away mode, the user code consists of 9 + 9 +
COMMAND
or, 9 + 9 +
9 + 9 without
COMMAND
.
There is no provision in the 532XR for adding any other user codes.
Menu Options
All three operating modes of the 532XR have access to the User Menu options listed below. To enter the
menu, press the COMMAND key until MENU? NO YES is displayed, then press the select key under YES.
At the ENTER CODE: prompt, enter 9 + 9 + COMMAND. Once in the menu, you can use the COMMAND
and ARROW keys to scroll through the available options.
Alarm Silence
Simulates silencing an alarm.
Sensor Reset
Simulates resetting sensors.
Door Access
Simulates a five second relay output.
Armed Areas
Displays current armed areas in the system.
System Test
This option always displays SYSTEM OKAY.
User Codes
Simulates adding and deleting user codes.
Schedules
Simulates setting permanent, temporary, and
output schedules. Memory is provided for one
schedule.
Display Events
Allows you to view up to five simulated events held
in memory. These events are programmed into the
keypad's firmware and cannot be changed by the
user.
Figure 2A: Hold for All/Perimeter
1
2
3
4
5
6
7
8
9
0
COMMAND
A B C
DEF
GHI
JKL
VWX
STU
PQR
MNO
YZ
POWER
Figure 2B: Hold for Home/Away
1
2
3
4
5
6
7
8
9
0
COMMAND
A B C
DEF
GHI
JKL
VWX
STU
PQR
MNO
YZ
POWER
Hold
Hold
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
Digital Monitoring Products