LT-1592 1.02 21362

Specifications

Primary Power  12 VDC from panel

Current Draw 

Standby      20 mA

Alarm          20 mA (47 mA peak transmitting)

Ordering Information

263LTE-V          Cellular Communicator for Verizon LTE
263LTE-A          Cellular Communicator for AT&T LTE

Accessories

381-2 18” Coax Cable

381-12 12’ Coax Extension

381-25 25’ Coax Extension

383 Dual Band Antenna (included)

386 Antenna Mounting Bracket
263EXT Cellular Extension Module

Compatibility

XT30/XT50 Series Version 212 and higher

XR150/XR550 Series Version 212 and higher

Certifications

California State Fire Marshal (CSFM)
FCC Part 15: RI7ME910C1NV (Telit)
                     RI7ME910G1W1 (Telit) 
                     XMR201707BG96 (Quectel)
                     XMR201907BG95M3 (Quectel)
Industry Canada: 5131A-ME910C1NV (Telit)
                             5131A-ME910G1W1 (Telit)
                             10224A-201709BG96 (Quectel)
                             10224A-2019BG95M3 (Quectel)

New York City (FDNY)
Underwriters Laboratory (UL) Listed

•  ANSI/UL 294   Access Control System Units 
•  ANSI/UL 636   Holdup Alarm Units and System  

                         Accessory

•  ANSI/UL 1023  Household Burglar
•  ANSI/UL 1076  Proprietary Burglar
•  ANSI/UL 1610  Central Station Burglar
•  ANSI/UL 1635  Digital Burglar

•  ANSI/UL 985   Household Fire Warning

•  ANSI/UL 864   Fire Protective Signaling 9th Edition.
•  ANSI/UL 365    Police Sta. Connected Burg Alarm 

Units & Systems

•  ANSI/UL 609   Local Burg Alarm Units & Systems

Underwriters Laboratory of Canada (ULC) Listed

•  ULC S304         Central Station Burglar
•  ULC - Subject - C1023   Household Burglar
•  ULC/ORD - C1076 Proprietary Burglar
•  ULC - S545       Household Fire
•  ULC  -  S559              Equipment  for  Fire  Receiving                                                                                                                                        

                         Centers and Systems

FCC INFORMATION

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. 

This device may not cause harmful interference, and

2. 

this device must accept any interference received, including interference that may cause undesired operation.

The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not 

be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority 

to operate the equipment.

Note

: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect equipment into an outlet on a circuit different from that to which the receiver is connected.
•  Consult the dealer or an experienced radio/TV technician for help.

Industry Canada Information

This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions: 

1. 

This device may not cause interference, and

2. 

this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux 

deux conditions suivantes:

1. 

l’appareil ne doit pas produire de brouillage, et

2. 

l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre 

le fonctionnement.

This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. 

The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain 

compliance with the General Population limits.

L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le Code de 

sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne d’une personne 

présente en conformité avec les limites permises d’exposition du grand public.