PROGRAM THE PANEL
Remove the Battery Isolation Tab
To activate the battery, remove the battery isolation pull tab. When
removed, the key fob will be active and may be programmed into the
system. See Figure 3.
Program the Key Fob
After completing each of the following steps, press
CMD
to advance to the next option. Refer to the appropriate
panel programming guide as needed.
1. At a keypad, enter
6653
(PROG) to access the Programmer Menu.
2. (1144E Series only) Go to
SYSTEM OPTIONS
. At
1100 ENCRYPTION
, select
ALL
to only add encrypted wireless
devices to the system. Select
BOTH
to allow both encrypted
and non‑encrypted wireless devices to be programmed.
3. (1144E Series only) The default passphrase is displayed at the
ENTER PASSPHRASE
prompt. Press
CMD
to keep the default.
Press any select key or area to change the passphrase and
enter an 8‑character hexadecimal string (0‑9, A‑F).
4. (XR Series panels only) To enable panic supervision for the
1144‑1P‑PSV, go to
SYSTEM OPTIONS
. At
PANIC SUPERVISION
,
select
YES
.
5. Go to
ZONE INFORMATION
and enter the wireless zone number. Refer to Table 2 for zone numbers.
6. (XT Series panels only) At
KEYFOB
select
YES
.
7. At
KEY FOB USER NUMBER
, enter an existing user number to be associated with the key fob. If the user
does not exist, the keypad displays
USER X NOT IN USE
. The key fob can be programmed, but the user
must be created for it to function properly.
8. At
TRANSMITTER SERIAL#
, enter the eight‑digit key fob serial number.
9. At
TRANSMITTER SUPRVSN TIME
, select a supervision time for the key fob. The default is
0
minutes. For
applications where the key fob may be taken off‑site, supervision time should be set to
0
(zero).
Program Key Fob Buttons
Refer to Table 3 when programming button actions.
1. At
NO. OF KEY FOB BUTTONS
,
enter the number of buttons on
the key fob (1, 2, or 4).
2. At
BUTTON
, select the button
that you want to program:
TOP
,
BTM
,
LFT
, or
RGT
.
3. At
BUTTON ACTION
, choose an
action for the button.
4. Configure press time or output
options as needed.
5. Repeat the steps in this section
as needed for each key fob
button.
6. At the
NEXT ZONE
prompt,
select
YES
if you are finished
programming the zone. Select
NO
if you would like to access
additional programming options.
7. To save panel programming, go
to
STOP
and press
CMD
.
Program the 1144-1P and 1144-2P Credential
Present the credential to a keypad or card reader to program the user credential. For information about adding
user codes, refer to the panel user guide.
PULL
Remove Battery
Isolation Tab to
Activate Battery
Figure 3: Battery Isolation Tab
PANEL MODEL
ZONE NUMBERS
XR150/XR550 Series
400‑449
XT30/XT50 Series
31‑34 (slow)
41‑44 (fast)
XTLplus and XTLtouch
51‑54 (slow)
61‑64 (fast)
Table 2: Key Fob Zone Numbers
ACTION
SELECT
OPTIONS
Arm
ARM
Short/Long Press, Arm/Disarm Areas
Disarm
DIS
Short/Long Press, Arm/Disarm Areas
Toggle
TGL
Short/Long Press, Arm/Disarm Areas
Status LED
STA
Short/Long Press
Panic
PN
Output Number, Output Action
Panic (2‑button)
PN2
Output Number, Output Action
Emergency
EM
Output Number, Output Action
Emergency (2‑button)
EM2
Output Number, Output Action
Output
OUT
Output Number, Output Action
Sensor Reset
RST
Short/Long Press
Unused
UN
‑
Table 3: Key Fob Button Programming Information