1128INT INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
3
5
TEST THE 1128INT GLASSBREAK DETECTOR
Handheld Glassbreak Test
To test the 1128INT, use a handheld tester like the FG-701 to imitate glass breaking. For more information, refer
to the glassbreak tester manual.
1. Set the tester to flex mode.
2. Place the FG-701 near the protected glass and press the button to activate the simulator. It will not
annunciate the sound of shattering glass until a low-frequency shock is also generated.
3. To generate the shock, slam a framed door to generate the appropriate low-frequency shock. The
shock will also activate the FG-701 simulator,
Note:
The 1128INT has two onboard microphones. Both the high frequency and low frequency
microphones must be activated to send an alarm to the control panel. If only the low frequency
microphone activates, the LED on the 1128INT will flash green. When both activate, the LED will flash red
and the 1128INT will transmit an alarm to the control panel.
Wireless Check-in Test
After the transmitter has been installed, test to confirm that it is communicating reliably with the panel. Use
the Tech APP™ to perform a Wireless Check-in Test on the system or complete the following steps to perform
a Check-in Test from a keypad that is connected to the panel.
1. At the keypad for XT Series panels, enter
8144
(WALK). At the keypad for XR Series panels, enter
814
(WAL).
2. Select
WLS
.
3. If the 1128INT fails to check in at the keypad, relocate the wireless device, receiver, or panel.
Glassbreak Check-in Test (v7.0.0.2 and higher)
When the 1128INT is set into testing mode from the panel, it will trip using the tester only. There is no need to
generate shock trip to the detector. XTINT and XRINT Series firmware Version 191 is required to perform the
glassbreak walk test.
1. Reset the panel.
2. If using an XT Series International Panel, enter
8144
(WALK). If using an XR Series International Panel,
enter
814
(WAL).
3. Select
PIR
. All 1128INTs on the system will begin flashing a green LED every 3 seconds to indicate that
they are in testing mode. It can take up to 3 minutes for all 1128INTs to enter testing mode
Note:
The PIR option will enable testing of all supported wireless PIRs and 1128INTs on the system.
4. Set the tester to manual mode.
5. Place the FG-701 near the protected glass and press the button to activate the simulator. If the 1128INT
is in range, it will flash the LED red for 3 seconds to indicate it detected the crash.
6. The 1128INT will remain in testing mode for 30 minutes or until the panel is reset.
ADDITIONAL INFORMATION
Replace the Battery
1. Remove the holding screw at the lower end of the 1128INT and gently lift off the cover.
2. Remove the old battery and dispose of it properly.
3. Observing polarity, place the new battery in the holder and press into place.
Note:
Use only 3.0 V lithium CR123A batteries.
4. Place the cover back onto the 1128INT and tighten the holding screw back into place.
Sensor Reset to Clear LOBAT
When the battery needs to be replaced, a
LOBAT
message will display on the keypad. Once the battery is replaced, a
sensor reset is required at the system keypad to clear the
LOBAT
message.
1. On a Thinline keypad, press and hold “
2
” for two seconds. On a touchscreen keypad press
RESET
.
2. Enter your user code if required.
3. The keypad displays
SENSORS OFF
followed by
SENSORS ON
.