Specifications

Battery
 

Life Expectancy 

3 years

 

Type 

 

3 V lithium CR123A

Frequency Range   

863-869 MHz

Detection
 

Range 

 

90° 40 x 40 ft

 

Speed 

 

1 - 5 ft/sec

Mounting Height   

4.9 to 8.2 ft

Transmit Condition 

Alarm, Low Battery, Tamper

Dimensions 

 

5”L x 2.6”W x 1.5”H

Color 

  White

Housing Material   

Flame retardant ABS

Patents

U. S. Patent No. 7,239,236

International Certificates

Intertek (ETL)

EN 50130-4:2011   

EMC - Product Family Standard. 

 

 

 

 

Immunity Requirements for 

 

 

 

 

Components of Fire, Intruder, and 

 

 

 

 

Social Alarm Systems.

EN 50130-5:2011   

Alarm Systems. Environmental Test 

   

 

Methods

EN 50131-1:2006+A1;A2 

Alarm Systems. Intrusion and Hold- 

 

 

 

 

up Systems. System Requirements

EN 50131-2-2 

 

Alarm Systems - Intrusion and Hold- 

 

 

 

 

up Systems- Passive Infrared 

   

 

Detectors

EN 50131-5-3:2017  

Alarm Systems. Intrusion systems. 

 

 

 

 

Requirements for Interconnections 

 

 

 

 

Equipment using Radio Frequency 

   

 

Techniques

EN 61000-3-2:2009+A1;A2 Limits - Limits for Harmonic Current 

 

 

 

 

Emissions (Equipment Input Current 

 

 

 

 

less than or equal to 16 A per Phase)

EN 6100-3-3:2013  

Limits - Limitation of Voltage 

 

 

 

 

Changes, Voltage Fluctuations and 

 

 

 

 

Flicker in Public Low-Voltage 

 

 

 

 

Supply Systems, for Equipment 

 

 

 

 

With Rather Current for less than or 

 

 

 

 

equal to 16 A per Phase and Not 

 

 

 

 

Subject to Conditional Connection

EN 6100-6-4:2018  

Generic Standard - Emission 

 

 

 

 

Standard for Industrial 

   

 

Environments

I N T R U S I O N   •   F I R E  •   A C C E S S  •   N E T W O R K S

2500 North Partnership Boulevard

Springfield, Missouri 65803-8877

417.831.9362  |  DMP.com

© 2022

Содержание 1122INT

Страница 1: ...D 4 Select NT Night as the ZONE TYPE 5 Select the AREA 6 At NEXT ZN select NO 7 Select YES when WIRELESS displays 8 Enter the eight digit SERIAL and press CMD 9 Enter the SUPRVSN TIME and press CMD 10 Choose whether to enable DISARM DISABLE Select YES to allow the 1122INT to be disabled for Night and Exit zones while the area is disarmed 11 Choose either 2 or 4 for the PULSE COUNT The pulse count ...

Страница 2: ...ocation Don ts Don t locate on a surface exposed to moisture Don t locate on any area containing excessive metallic surfaces Don t locate within direct sunlight head sources heaters radiators etc or strong air drafts fans air conditioner etc in the field of view Check the Location Using Survey LED 1 Hold the 1122INT in the exact desired location 2 Press the tamper switch to send data to the receiv...

Страница 3: ...ypad for XR Series panels enter 814 WAL 2 Select WLS 3 If the 1103INT fails to check in at the keypad relocate the wireless device receiver or panel ADDITIONAL INFORMATION Replace the Battery 1 Remove the holding screw at the lower end of the 1122INT and gently lift off the cover 2 Remove the old battery and dispose of it properly See Figure 2 for battery location 3 Observing polarity place the ne...

Страница 4: ...50131 1 2006 A1 A2 Alarm Systems Intrusion and Hold up Systems System Requirements EN 50131 2 2 Alarm Systems Intrusion and Hold up Systems Passive Infrared Detectors EN 50131 5 3 2017 Alarm Systems Intrusion systems Requirements for Interconnections Equipment using Radio Frequency Techniques EN 61000 3 2 2009 A1 A2 Limits Limits for Harmonic Current Emissions Equipment Input Current less than or ...

Отзывы: