Wireless Bus Connection

On XR150/XR550 Series panels, the 1100XH interfaces using the on-board X-BUS header. The receiver can be hard-wire 

mounted up to 100 feet from the panel enclosure using 22 AWG wire or 250 feet using 18 AWG wire. This wire restriction is 

due to the higher current draw needed for the high power RF amplification.
If additional wire distance is required, the 1100XH can be connected to the Wireless Bus through a 710 Bus/Splitter module 

and powered by a 12VDC power supply (DMP Model 505-12). Please see the 710 Installation guide (LT-0320) for maximum 

distance information from the panel to the 710 module. The 1100XH High Power Wireless Receiver cannot operate if 

connected to the Keypad Bus.

Harness Connection XR150/XR550 panels

1.  Connect the PANEL header on the 1100XH to the XR150/XR550 panel XBUS header.
2.  After power-up, briefly reset the panel using the RESET header to activate wireless zone operation.
3.  In System Options, program the House Code (1-50). The panel immediately recognizes the 1100XH Receiver if the 

panel is programmed with a house code.

4.  In Zone Information, program the wireless zones.
5.  Snap the cover back on the unit making sure the case tamper spring is installed on the tamper switch. 

1100XH Receiver Operation

The 1100XH receiver automatically sends the panel house code to wireless transmitters when the unique transmitter serial 

number is programmed into the panel. The house code identifies the panel, receiver, and transmitters to each other. The 

receiver only listens for transmissions using the specified house code and/or programmed transmitter serial number.
Note: When setting up a wireless system, it is recommended to program zones and connect the receiver before installing 

batteries in the transmitters.
Transmitters can be programmed for supervised operation. When programmed as supervised, the transmitter must 

communicate with the receiver within the programmed number of minutes. If the transmitter fails to communicate, the 

panel displays a missing condition.
Note: When a receiver is installed, powered up, or the panel is reset, the supervision time for transmitters is reset. If the 

receiver has been powered down for more than one hour, wireless transmitters may take up to an additional hour to send 

a supervision message unless tripped, tampered, or powered up. This operation extends battery life for transmitters. A 

missing message may display on the keypad until the transmitter sends a supervision message.
When any wireless zone programming is changed in the panel, receiver zone programming is updated. At that point, all 

wireless zones display as normal for approximately one minute, regardless of the actual state of the contact.

Black

Green

Yellow

Red

Can be extended

up to 100 feet

from the panel

using 22 AWG

or 250 feet 

using 18 AWG

1100XH 

Receiver

U10

U11

1

TO PANEL

Panel Receive

Panel Transmit

Status

RF Receive

RF Transmit

1

U8

Y1

L17

1

Tamper

Switch

2-pin Header

XR150/XR550 

Series Panel

Battery Start

Power

LED

REC

 - Receive LED

XMT

 - Transmit LED

Figure 3: Harness Connection 