1.3    Performance criteria: 
 

Operating humidity                                        ≤ 75% 
Storage humidity                                            ≤ 95% 
Operating temperature                                  -10°C - +50°C 
Storage temperature                                      -30°C - +70°C 
International standard  

                        IEC 62053-21 

Accuracy class  

 

 

 

                1 

Protection against penetration                 
of dust and water                                            IP51 

Insulating encased meter of   
protective class                                               

 

 
 

1.4    Specifications: 
                           

Meter type                                                          PRO-1TE(register display)   

PRO-1TE LCD (LCD display) 

Nominal voltage  (Un) 

                         230V AC 

Operational voltage 

                                 161 - 300V AC 

Insulation capabilities:  
- AC voltage withstand                                   2KV for 1 minute 

 

- Impulse voltage withstand                        6KV – 1.2µS waveform 
Basic current (Ib)   

 

 

                 5A 

Maximum rated current (Imax) 

45A 

Operational current range   

 

         0.4% Ib- Imax    

Over current withstand  

 

                 30Imax for 0.01s 

 

 

Operational frequency range   

         50Hz ±10%  

 

 

Internal power consumption 

 

         ≤2W / 10VA  

 

 

Test output flash rate (RED LED)   

1000/kWh 

Pulse output rate (pins 20 & 21) 

 

1000/kWh 

Consumption indicator (RED LED)            Flashing at load running 

 
 

1.5    Basic errors: 
 

0.05Ib 

               

Cosφ = 1                   

±1.5% 

0.1Ib   

 

       

Cosφ = 0.5L 

 

         ±1.5% 

   

 

 

 

 

Cosφ = 0.8C 

 

         ±1.5% 

0.1Ib - Imax                Cosφ = 1   

           

±1.0% 

0.2Ib - Imax                Cosφ = 0.5L 

 

         ±1.0% 

   

 

 

 

 

Cosφ = 0.8C 

 

         ±1.0% 

 
 
 

1.6    Description

 

 

A   

 

 

 

        Register(or LCD) 

B   

 

 

 

        Terminal block 

C   

 

 

 

        Case 

D                                            Protection cover 
E                                            Security hasp 

 
 

Содержание PRO-1TE Series

Страница 1: ...e phase two wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Basic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troubl...

Страница 2: ...start up ground and label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases...

Страница 3: ...ademark of Inepro Industries Ltd member of the Inepro Group The other names appearing in this manual may be trade names the use of these names by third parties for their own purposes may infringe the...

Страница 4: ...capabilities AC voltage withstand 2KV for 1 minute Impulse voltage withstand 6KV 1 2 S waveform Basic current Ib 5A Maximum rated current Imax 45A Operational current range 0 4 Ib Imax Over current wi...

Страница 5: ...ver ABS inflammable retarding 1 7 Dimensions Height 117 5 mm Width 18 mm Depth 58 5 mm Weight 0 12 Kg net 1 8 Installation CAUTION Turn off and lock out all power supplying the energy meter and the eq...

Страница 6: ...erous or dusty environment The meter can be installed and used after being tested and sealed with a letter press printing The meter can be installed on a 35mm DIN rail The meter should be installed in...

Страница 7: ...intenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for h...

Страница 8: ...ide circuit Check that the power supply indicator is burning If the operating power is too low the spacing interval of the pulses will take some more time this is why it seems like the meter won t cou...

Страница 9: ...ts please contact DMMetering dealer in your in your region Your local DMMetering distributor Email support dmmetering com www dmmetering com Inepro Industries Ltd Room 3208 Central Plaza 18 Harbour Ro...

Отзывы: