DMC WA22AE Скачать руководство пользователя страница 2

DANIELS 

MANUFACTURING 

CORPORATION 

DATASHEET 

CHECKING  THE  FULL  CYCLE  RATCHETING  MECHANISM 

The  ratcheting  mechanism  can  be  checked  for  proper  functioning 
by  the  following  procedure. 

1.  Adjust  the  air  line  pressure  to  15  p.s.i. 

2.  Select  the  appropriate  contact  and  wire  as  determined  on 

the  positioner  dataplate.  Operate  the  tool  until  the  indenters 
stop.  The  indenters  will  not  reach  the  fully  closed  position  and 
the  contact  will  be  locked  in  if  the  ratcheting  mechanism  is 
functioning  properly. 

3.  To  release  the  partially  crimped  contact,  increase  the  air 

line  pressure  to  80-120  p.s. i.  and  operate.  The  tool  will 
then  complete  the  crimp  allowing  the  indenters  to  return  to 
the  fully  open  position. 

RELEASING  A  PARTIALLY  CRIMPED  CONTACT 

To  release  a  partially crimped  contact,  proceed  as  follows: 

1.  Increase  the  air  pressure  to  120  p.s.i.  and  operate  the  unit. 

2.  If  release  has  not  been  achieved  after  several  attempts,  contact 

DMC  Service  Department. 

PAGE  2 