background image

 

DER-S0081A 

Rev. 4.0 ©2005 - 2011 DMC Co., Ltd. 

FST Series Product Specifications

5. Handling Notes 

5-1. Precautions 

§ This product is intended for use in standard applications (computers, office automation, and other office 

equipment, industrial, communications, and measurement equipment, personal and household devices, 
etc.) Please avoid using this product for special applications where failure or abnormal operation may 
directly affect human lives, or cause physical injury or property damage, or where extremely high levels 
of reliability are required (such as aerospace systems, vehicle operating control, atomic energy controls, 
medical devices for life support, etc.). 

 

5-2. Handling Notes 

§ Do not depress or scratch the product with any object with a sharp edge or end. 
§ Do not forcibly bend or fold the product. 
§ When the product is stored, make sure it is packed in a packing box and stored in a storage temperature 

range, eliminating any outside load. 

§ Do not use or store the product under a condition where the product will be exposed to water, organic 

solution or acid. 

§ Do not use the product under the direct sunlight. 
§ Do not disassemble the product. 
§ When you handle the product, Hold the product by its body. Do not hold by the tail. 
§ Clean the product with a soft cloth or a soft cloth with neutral detergent or alcohol. When contaminated 

by chemicals, wipe them off immediately with caution not to cause injury to human body. 

§ The edge of the glass is not rounded and may cause injury. 
 

5-3. Construction Notes 

§ The environmental specifications, mechanical characteristics, and electrical characteristics are only 

applied to the Active Area.   

§ Do not use the touchscreen when the condensation occurs. The condensation inside of the touchscreen 

is a natural phenomenon and should disappear after the touchscreen is warmed up.   

 

5-4. Electrical & Software Notice 

The best performance can be obtained when used with the original 5 wire analog resistive touchscreen 
controller, “TSC-20” Series. If the touchscreen controller or controller software is to be developed by the 
customer, please note the following: 
§ There is a contact resistance between the top and bottom electrodes and it changes by the pressure of a 

finger or a pen. The data must be read after the contact resistance becomes stabilized. 

§ The terminal resistance of the 5 wire analog resistive touchscreen varies by the individual, time, and 

environment. The controller software must have the calibration function to adjust the input position and 
the display position. 

§ The 5 wire analog resistive touchscreen outputs 2 point input as 1 point in between the 2 points. The 

controller software must not be designed to have the 2 point input function. 

§ For drawing applications, the line may be intermittent when the pen comes on the dot spacers. A 

software compensation is needed. 

 

Содержание 5 Wire Analog Resistive Touchscreen FST Series

Страница 1: ...5 Wire Analog Resistive Touchscreen FST Series Product Specifications...

Страница 2: ...5 2 2 Environmental Specifications 5 2 3 Mechanical Characteristics 5 2 4 Electrical Characteristics 5 2 5 Appearance 6 3 Reliability Condition 7 3 1 Temperature Condition 7 4 Recommended Connector 7...

Страница 3: ...g m3 no condensation Chemical Resistance top surface Toluene Tricholoroethylene Athetone Alcohol Gasoline Machine Oil Ammonia Glass Cleaner Mayonnaise Ketchup Wine Salad Oil Vinegar Lipstick etc 1 4 M...

Страница 4: ...eptable 0 4 D 0 3 1 1pcs in viewing area 1 0 3 D 0 2 2pcs in 30mm Circular Scratch Dust 0 2 D Acceptable Within 5pcs panel Applied only in the Active Area Scratches or dusts in the outside of the Acti...

Страница 5: ...od Judgement Must satisfy the specification Operating Life Test Finger Condition Testing rod Refer to Figure 1 Voltage DC5V Load 3N Cycle 2 hits sec Judgement Must satisfy the following Activation For...

Страница 6: ...nce Test Neighboring Terminals Measured by applying the reference voltage to the terminals Active Area Electrodes Measured by applying the reference voltage to the top and bottom electrodes Judgement...

Страница 7: ...idity 90 to 95 for 240 hours and in the room temperature for 2 hours Cycle Test Tested after 5 cycles of leaving the parts in the temperature 30 C 3 C for 1 hour and in the room temperature for 0 5 ho...

Страница 8: ...ohol When contaminated by chemicals wipe them off immediately with caution not to cause injury to human body The edge of the glass is not rounded and may cause injury 5 3 Construction Notes The enviro...

Страница 9: ...t not be forcibly stressed or bent too hard to avoid the conduction in the insulated area and wire breaking Mounting Touchscreen must be held from the bottom such as the structure gluing the touchscre...

Страница 10: ...fer by the user Any malfunctions and damages caused by a natural disaster or a fire Any malfunctions and damages caused by static electricity Any malfunctions and damages caused by the failure of the...

Страница 11: ...rea are acceptable unless the electrical characteristics are affected 2 4 Added Operating Life Test Pen Rev3 0 March 23 2010 1 6 Appearance specification was revised Characters of scratch dust were cl...

Страница 12: ...DER S0081A 12 Rev 4 0 2005 2011 DMC Co Ltd FST Series Product Specifications 6 6 RoHS Compliance Description about RoHS compliance has been added...

Страница 13: ...ons Rev 4 0 August 25 2011 2005 2010 DMC Co Ltd This document can be freely distributed but any alternation to this document is prohibited http www dmccoltd com english 9th floor Kanda Sento Building...

Отзывы: