FlexxPump 1500 is designed for minimum quantity lubrication.
The microprocessor calculates from the inputs of pause time and numer of cycles a
comparison value. If this value is too high, a reduction in the lifetime of FlexxPump
1500 is accepted consciously.
Warning: The ALARM LED flashes on the control panel and the display shows "InF" (for
information) for 10s. During this 10s, the operation of FlexxPump 1500 is blocked.
Acceptable Design
Attention: FlexxPump 1500 is designed for minimum quantity lubrication
A higher demand for lubricant at one lubricating point the outlets of different pump units can be combined externally.
Important remark: unused outlets must remain open to avoid damage to the pump!
Examples:
4 outlets supplying 1 lubrication point:
Allowed amount of lubricant for 1 lubrication point
= max.
6.000cm³ a year = 4 pouches a year for 1 lubrication
point
or
Allowed amount of lubricant for 2 lubrication point
= max.
12.000cm³ a year = 8 pouches a year for 2 lubrication
i t
Attention !
1 outlet supplying 1 lubrication point:
Allowed amount of lubricant for 1 lubrication point
= max.
1.500cm³ a year = 1 pouch a year for 1 lubrication point
or
Allowed amount of lubricant for 2 lubrication point
= max.
3.000cm³ a year = 2 pouches a year for 2 lubrication
points
2 outlets supplying 1 lubrication point:
Allowed amount of lubricant for 1 lubrication point
= max.
3.000cm³ a year = 2 pouches a year for 1 lubrication
point
or
Allowed amount of lubricant for 2 lubrication point
= max.
6.000cm³ a year = 4 pouches a year for 2 lubrication
points