background image

16

1

 BATTERY SYSTEM TESTER

1.Brief Introduction

       DI-216/DI-217 battery storage testers are used for 
activated style lead-acid storage battery, along with checking 
the following conditions of the battery, starting up, charging, 
and electrical loading. With great design, easy operation, 
precise reading, complete functions, this tester supply the 
readings by a large LCD and hints by sound and light when 
testing. Precise circuit and strong digital processing unit make 
it complete collection of a series of complicated data and figure 
out every test data, which availably by 4-wire Kelvin test 
connection. Besides it strengthens input protection inside , in 
order to prevent such situations as polar reversal connection , 
over-high voltage input, poor contact of the test clamps and so 
on. That makes sure safer and more convenient when testing.

       This tester is the best tool for battery sales, vehicle repair 
and condition check of all kinds of lead-acid batteries that used 
in equipment system associated with lead-acid battery.

2.Safety Rules And Attentions

        This manual includes instruction, operation warning and 
maintenance. It is possible to damage the tester without 
regulations in this manual. This tester is designed and 
produced strictly according to GB4793.1 electronic 
measurement instrument safety requirement and 
IEC/EN61010-1 safety standard. It also reach double insulation 
over voltage standard CAT

Ⅲ 

600V and pollution degree 2 .

(1) DI-216/DI-217 is available to vehicle of 12V storage battery.

(2) The working voltage of DI-216/DI-217 is DC 9V to 18V. Make 
sure do not check the series connection battery.  

(3) The voltage value will be higher than that in the normal 
situation after the checked battery being fully charged . Please 
turn on the headlights for 2 to 3minutes, then check the battery 
when it’s voltage value drop to the normal value.

(4) Check the insulating layer of the clamps before measuring. 
Damage, bareness and disconnection are unacceptable. It is 

8-2 It is unavailable to know the electric quantity of 
storage battery by intuition

       Hydrometer can be used to check the condition of the 
battery. Battery water is distilled water and pure sulfuric acid of 
the proportion of 1.260/20°C to allocate. For a new battery, it is 
supposed to supply distilled waterwith reduction of battery water 
for the reason that the degree of acid is fixed when the quantity 
of battery water remain the normal range. Distilled water 
supplement can maintain a certain amount of water, but alsothe 
PH value. If the battery works normally, in addition to the PH is 
fixed, the proportion of the value will be in a certain range. 

       If the battery finishes charging, the proportion of battery 
water does not reach 1.26-1.28, along with the tested voltage 
under 12.7V, the storage capacity of this battery has descended. 
It is impossible to recover its life by deliberately adjusting the 
proportion to 1.26 (Increase the sulfuric acid water), on the 
contrary shorten its life fast for the reason that it will increase 
the acidity of battery water, not the voltage however.

8-3 Some common abbreviation meaning of storage 

★ 

RC

Reserve Capacity

       Every storage battery has the ability to load averagely 25A 
electric perminute and maintains lowest 10.5V more or less in 
the situation of 80°F(27°C).

★ 

CCA

Cold Cranking Ampere

       With the fixed current, every battery can be cooled in the 
situation of 0°F(-18°C) ~

 

-20°F(-29°C)for 30 seconds and 

 

 

 

 

Battery of small type vehicle

Voltage

(

V

)

 

Electric(%)

 

Proportion

>12

.

7

 

100%

 

1

.

26~1

.

28

12

.

6

90%

 

1

.

24

12

.

4

70~80%

 

1

.

22

12

.

1

50%

1

.

16

<12

25%

<1

.

13

USER MANUAL

Содержание DI-216

Страница 1: ...TIVE BATTERY SYSTEM TESTER Diligent Instruments Corporation Address 2802 Fanshawe Street Philadelphia PA 19149 Phone 215 316 4516 Email dlginstruments gmail com www diligentinstruments com Product distributed in the United States by Diligent Instruments Corporation and made in China DLG Applicable model DI 216 DI 217 USER MANUAL ...

Страница 2: ...0V 30 seconds with the lowest voltage while 8 0V 150seconds IEC International Electrotechnical Commission Under an average current every battery cooled in the situation of 0 F 18 C can load the lowest voltage of 8 4Vfor 60 seconds BSR Battery Saving Ratio Under an average current every battery cooled in the situation of 0 F 18 C can load the lowest voltage of 6 0Vfor 180 seconds BCI Battery Commis...

Страница 3: ...ion after the checked battery being fully charged Please turn on the headlights for 2 to 3minutes then check the battery when it s voltage value drop to the normal value 4 Check the insulating layer of the clamps before measuring Damage bareness and disconnection are unacceptable It is 8 2 It is unavailable to know the electric quantity of storage battery by intuition Hydrometer can be used to che...

Страница 4: ...0528 410 680 55422 55566 55040 265 450 61017 61018 400 680 55428 55423 55427 300 510 61023 62529 450 760 55457 265 450 61047 61048 450 760 55529 220 360 62034 62038 62045 420 680 55531 55545 55559L 255 420 63013 470 680 55559 55530 88056 255 420 63545 63549 420 680 55564 55552 55563 255 420 64020 64317 64318 325 550 55564 55565 55548 255 420 64028 64035 520 760 55570 55567 55565L 255 420 64036 460...

Страница 5: ...8D26R N50 280 360 420 150F51R NT200 12 640 48D26L N50L 280 360 420 150F51L NT200 12L 640 50D20R 310 380 480 165G51R NS200 935 980 50D20L 310 380 480 165G51L NS200L 935 980 50D23R 85BR60K 500 170F51R NX250 12 1045 50D23L 85B60K 500 170F51L NX250 12L 1045 Continue table 7 2 Comparison table of DIN EN MODEL THE SAME MODEL DIN EN MODEL THE SAME MODEL DIN EN 52805 52815 180 240 56420 56322 88066 300 51...

Страница 6: ... 880 38B20LS NX60 24LS 330 340 410 105E41L N100ZL 580 720 880 40B20L 330 105F51R N100Z 580 40B20R 330 105F51L N100ZL 580 42B20R 330 115E41R NS120 650 800 960 42B20L 330 115E41L NS120L 650 800 960 42B20RS 330 115F51R N120 650 800 960 42B20LS 330 115F51L N120L 650 800 960 46B24R NS60 325 360 420 130E41R NX200 10 800 46B24L NS60L 325 360 420 130E41L NX200 10L 800 46B24RS NS60S 325 360 420 130F51R 800...

Страница 7: ...ently 40 80A large current is available go through the battery shortly about 2 3 seconds And then the tested voltage of the battery can be used to figure out the internal resistance by the formula The disadvantage of this method 1 Just available for large capacitance battery or storage battery The small capacitance battery can not load 40 80A large current in 2 3 seconds 2 When the large current g...

Страница 8: ...ntration polarization internal resistance chemical reactions internal resistance and interference effect caused by double capacitance s charging The ingredient of internal resistance and its relative content will change with different test method and different test moment which can lead to different tested value of the internal resistance And there is no strict relationship between internal resist...

Страница 9: ...r to avoid affected result 2 Press to select activation load test as the picture below following picture and accompanied by a beep prompt and flash screen 7 Press ESC to return step 3 5 3 3 There are some problems in the system If the voltage is high than 15 00V please check the voltage regulator If the voltage is lower than 13 30V please check the connections wires and the engine generator output...

Страница 10: ...t will appear the generator output current voltage generator output highest voltage generator output lowest voltage 3 After selecting the test item press ENTER to display the activation load test screen as the picture below Press to select The current instant voltage or Minimum starting voltage As can be seen in the picture current test voltage is 12 88V standard voltage is 9 6V and the lowest sta...

Отзывы: