background image

3

3.International Electric Symbol

4.Structure Of Meter

Introduction of button and clamp

<

><

>

:

increase, decrease, 

                 turn up/down the page 

<ESC>

:

cancel

undo

return 

<ENTER>

:

select

enter

test

the red clamp

:

 positive connection

the black clamp

:

 negative connection

5.Instructions Of Functions

5-1  storage battery voltage mode setting(DI-215A)

        Before testing, set the tested voltage according to the type of battery 

voltage. Select 12V mode for a 12V battery. Select 24V mode for a 24V 

battery. And then head to the following testing :storage battery test, engine 

system activation load test, maximum load system test, charging system test.

DC

AC

DC/AC

warning

dangerous voltage(electric

 

shock)

earth

double insulation

fuse 

battery

16

M o de l

Th e

 

s ame

 

model

DIN

EN

M od el

The

 

sam e

 

m ode l

DIN

EN

 

 

 

 

 

 

54 5 23

54524

220

300

58521

58513

320

540

5 45 3 7

5 45 45

54801

190

300

58522

58514

320

540

5 45 5 1

54580

 

220

 

300

 

58815

 

58821

 

395

640

5 45 3 3

54 577

 

54579

 

220

 

300

 

58820

 

5 45 8 4

54578

 

220

 

300

 

58827

 

 

400

640

5 45 9 0

 

210

 

330

 

58838

 

58833

 

88092

 

400

680

5 48 2 7

 

240

 

360

 

59040

 

59017

 

59018

 

360

600

5 50 4 0

88056

 

265

 

450

 

59218

 

59219

 

290

480

5 50 4 1

55042

 

220

 

360

 

59226

 

59215

 

450

760

5 50 4 4

5 5 414

 

88056

 

265

 

450

 

59514

 

 

320

540

5 50 4 6

300

510

59518

59519

395

640

5 50 5 6

320

540

59615

59616

360

600

58515

58527

395

640

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

550 5 7

54 8 27

 

88156

 

320

 

540

 

60018

 

60019

 

250

410

55 0 6 8

55 0 69

 

55548

 

220

 

390

 

60026

 

58811

 

440

720

55 2 1 8

 

255

 

420

 

60044

 

60038

 

500

760

55 4 1 4

5 5 415

 

55421

 

265

 

450

 

60527

 

60528

 

410

680

55 4 2 2

5 5 566

 

55040

 

265

 

450

 

61017

 

61018

 

400

680

55 4 2 8

5 54 23

 

55427

 

300

 

510

 

61023

 

62529

 

450

760

55 4 5 7

 

265

 

450

 

61047

 

61048

 

450

760

55 5 2 9

220

360

62034

62038

62045

420

680

55 5 3 1

55 5 45

55559L

255

420

63013

470

680

55 5 5 9

5 5 530

88056

255

420

63545

63549

420

680

55 5 6 4

5 5 552

55563

255

420

64020

64317

64318

325

550

55 5 6 4

5 5 565

55548

255

420

64028

64035

520

760

55 5 7 0

55 5 67

55565L

255

420

64036

460

760

56 0 1 2

230

390

64317

64318

64323

540

900

5 60 4 8

5 6 0 68

56069

250

390

65513

540

900

5 60 4 9

5 6 0 69

 

56073

 

250

 

390

 

65514

 

65515

 

570

900

5 60 7 7

56030

 

300

 

510

 

67043

 

67045

 

600

1000

5 60 9 1

55811

 

360

 

540

 

68032

 

68034

 

600

1000

5 61 1 1

55048

 

300

 

540

 

70029

 

70038

 

70027

 

630

1050

5 62 1 8

56092

 

300

 

510

 

70036

 

68040

 

68021

 

570

950

5 62 1 9

56216

 

300

 

510

 

71014

 

71015

 

700

1150

5 62 2 0

 

280

 

510

 

72512

 

 

680

1150

5 62 2 5

56323

300

510

73011

740

1200

5 63 1 8

5 6 312

56311

300

510

continue table

LCD

button

testclamp

Содержание DI-215

Страница 1: ...ERATING MANUAL DLG Diligent Instruments Corporation Address 2802 Fanshawe Street Philadelphia PA 19149 Phone 215 316 4516 Email dlginstruments gmail com www diligentinstruments com Product distributed in the United States by Diligent Instruments Corporation and made in China ...

Страница 2: ...bile Battery 8 1 the internal resistance of different types of battery differ 8 2 it is unavailable to know the electric quantity of storage battery by guessing 8 3 some common abbreviation meaning of storage battery standard 1 1 3 3 3 3 4 7 8 9 11 11 12 12 12 12 13 13 15 17 17 17 18 CONTENT DIN Deutsches Institut für Normung e V Under a cold temperature of 0 F 18 C the Ampere quantity is 9 0V 30 ...

Страница 3: ...ection battery 3 The voltage value will be higher than that in the normal situation after the checked battery being fully charged Please turn on the headlights for 2 to 3 water on the contrary shorten its life fast for the reason that it will increase the acidity of battery water not the voltage however 8 3 some common abbreviation meaning of storage RC Reserve Capacity Every storage battery has t...

Страница 4: ... of inconformity of internal chemical feature even if with the same type battery It is very small so that we generallydefine it with unit of milliohm Internal resistance is a significanttechnical standard to measure a battery Normally the battery with small internal resistance has a great ability to discharge On the contrary the battery with large internal resistance has a little ability to discha...

Страница 5: ...40 88056 265 450 59218 59219 290 480 55041 55042 220 360 59226 59215 450 760 55044 55414 88056 265 450 59514 320 540 55046 300 510 59518 59519 395 640 55056 320 540 59615 59616 360 600 58515 58527 395 640 55057 54827 88156 320 540 60018 60019 250 410 55068 55069 55548 220 390 60026 58811 440 720 55218 255 420 60044 60038 500 760 55414 55415 55421 265 450 60527 60528 410 680 55422 55566 55040 265 4...

Страница 6: ...0L 780 900 1100 48D26R N50 280 360 420 150F51R NT200 12 640 48D26L N50L 280 360 420 150F51L NT200 12L 640 50D20R 310 380 480 165G51R NS200 935 980 50D20L 310 380 480 165G51L NS200L 935 980 50D23R 85BR60K 500 170F51R NX250 12 1045 50D23L 85B60K 500 170F51L NX250 12L 1045 50B24R NT80 S6 390 180G51R NT250 15 1090 50B24L NT80 S6L 390 180G51L NT250 15L 1090 50D26R 50D20R 370 195G51R NX300 51 1145 50D26...

Страница 7: ...LS 275 300 360 95D31L NX120 7L 620 660 850 38B20R NX60 N24 330 340 410 95E41R N100 515 640 770 38B20RS NT60 N24S 330 340 410 95E41L N100L 515 640 770 38B20L NX60 24L 330 340 410 105E41R N100Z 580 720 880 38B20LS NX60 24LS 330 340 410 105E41L N100ZL 580 720 880 40B20L 330 105F51R N100Z 580 40B20R 330 105F51L N100ZL 580 42B20R 330 115E41R NS120 650 800 960 42B20L 330 115E41L NS120L 650 800 960 42B20...

Страница 8: ...ailable for large capacitance battery or storage battery The small capacitance battery can not load 40 80A large current in 2 3 seconds 2 When the large current going through the battery there comes out polarization phenomenon from internal electrode which can cause polarization internal resistance As a result it has to be tested in a short time Otherwise there is a large error of the internal res...

Страница 9: ...redict when does the battery become useless The internal resistance of the sealed lead acid battery is complicated It is generated by ohm internal resistance concentration polarization internal resistance chemical reactions internal resistance and interference effect caused by double capacitance s charging The ingredient of internal resistance and its relative content will change with different te...

Страница 10: ...tion off need to step the gas pedal when checking Voltage 13 5 13 2 13 5 13 0 13 2 13 Data Reference Table Condition normal general pay attention check immediately 12V system Headlights and air condition on need to step the gas pedal when checking The result can be affected by the defective battery 13 4 14 6 13 2 13 4 13 2 normal pay attention check immediately If the voltage is lower than 13 30V ...

Страница 11: ... 5 5 Charging system test 5 5 1 Preparation Please star the engine firstly 10 5 5 2 Procedure of operation 1 When the engine is working connect the red clamp to the positive polar of the battery and the black one to the negative polar Make sure they are well connected in order to avoid affected result 2 Speed the engine to 3000 rpm 3 Press to select charging system test as the picture below 4 Afte...

Отзывы: