26 / 26
6 Troubleshooting
Check the indicators on the front to determine the state of the battery pack. a
warning state is triggered when a condition, such as with voltage or current or
temperature, is beyond design limitations. The battery pack’s BMS periodically
reports its operating state to the inverter. when the battery pack falls outside
prescribed limits, it enters a warning state. When a warning is reported, the
inverter immediately stops operation. use the monitoring software on the inverter
to identify what caused the warning. The possible warning messages are as
follows:
Battery Over Voltage
Battery Under Voltage
Battery Over Temperature
Battery Under Temperature
Battery Discharge Over Current
Battery Charge Over Current
The abnormal state is cleared when the battery pack recovers normal operation.