A

 Motor body completely submersible and insulated by epoxy resin

B

 Rotor kit with Impeller and bottom bearing

C

 O-rings

D

 4 Suction cups 

E

 Water flow regulator from min. (-) to max. (+) assembled to pre-chamber

F

 Pre-filter Intake grill

G

 Threaded pre-chamber  1” Gas

H

 Hose Fittings

Proceed in the following way: take away the pre-filter (1), the ring nut (2) and 
then the threaded pre-chamber (3); take away the rotor (4) and rinse it under 
fresh water. Always check the condition of the o-rings (5). Any damage to the 
o-rings, even small, can seriously endanger the pump performances. In this 
case it is recommended to substitute them. Rinse each part with water, using 
a soft brush to remove the deposit. Then assemble everything in the inverse 
order.

For the periodic maintenance of the pump, first of all unplug the plug from the electric socket and then take the pump.

DL SILENT

2400

Q max

220 - 240 V

50 Hz

2400 l/h

H max

2.4 m

Watt

40 W

Cable lenght

2.2 m

DL SILENT

 2400

MAINTENANCE

COMPONENTS

Содержание +5500

Страница 1: ...INSTRUCTION MANUAL EN 5500 7000 2400 DL SILENT...

Страница 2: ...INSTRUCTION MANUAL EN DL SILENT 2400 5500 7000 WARRANTY SEAL AND SIGNATURE OF RESALE DEALER DATE OF PURCHASE ____ ____ ____ day month year...

Страница 3: ...ubstituted or repaired in case of damage replace the entire pump 5 ATTENTION do not operate any appliance if it has a damaged cord or plug if it is malfunctioning or if it has been dropped or damaged...

Страница 4: ...e fittings to the pump outtake to which you can connect the pipes with the appropriate diameter 2 Place the pump in an area easily accessible for the maintenance operations 3 If the pump is used subme...

Страница 5: ...the risk of the pump to run dry The risk of invisible air bubbles creating a vacuum area is very high Damages which are caused by the pump running dry are excluded from warranty To maximize the pump s...

Страница 6: ...the threaded pre chamber 3 take away the rotor 4 and rinse it under fresh water Always check the condition of the o rings 5 Any damage to the o rings even small can seriously endanger the pump perform...

Страница 7: ...n rubber feet E Turning pre chamber F Pre filter grid G Hose fittings for rigid flexible pipes DL SILENT 5500 7000 Q max 220 240 V 50 Hz 5500 l h 7000 l h H max 3 5 m 5 0 m Watt 40 W 55 W Cable lenght...

Страница 8: ...ring of the pump s volute pulling the tab outwards G Remove the ring H Remove the volute of the pump by turning and simultaneously pulling forward in the case of fouling this may take more pressure H...

Страница 9: ...water the pump after 20 attempts to start followed by a short interval of time and other 20 attempts will stop automatically If this does not happen the pump will automatically go on standby the elect...

Страница 10: ...tee is void and expires immediately The guarantee is also void in absence of the cash register receipt or similar document The shipping cost to and from the factory or the repair station have to be pa...

Страница 11: ...INSTRUCTION MANUAL EN DL SILENT 2400 5500 7000 SPECIAL FEATURES...

Страница 12: ...INSTRUCTION MANUAL EN 5500 7000 2400 DL SILENT...