background image

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

For COMPLETE programming instructions, please refer to the HARDwired Installation/Owner’s manual P/N 2358-065.

Copyright 2013 DoorKing, Inc. All rights reserved.

2358-066-F-2-14

34

33

32

31

30

29

28

27

26

25

24

23

22

21

14

15

16

17

18
19

20

13

12

11

10

9

8

7

6

5

4

3

2

1

ON

1

0

BOARD ADDRESS

0

9

8

7

6

5

4 3 2

1

NC

OUTPUT

RELAY

NO

NC

ALARM

RELAY

NO

NC

AUX

RELAY

NO

ENT

RESET

2358-010

RF

DATA

RF

SECURE

RF

STATUS

CODE

SENT

CODE

GOOD

CODE

BAD

LED Display

Programming

Buttons

Aux Relay

Alarm Relay

Output Relay

Tracker Communication Line

Ground - Required

Relay Communication Line (NO)

Request to Exit

Tracker Expansion Board Busy

Access Control Device

26, 30, 31-Bit Wiegand

Relay Communication Line (Com)

Card Reader LED/Beeper Control

Follow these basic steps to perform desired programming, See programming options table for PROGRAM STEPS.

After all tracker expansion boards have been programmed.....

1. Press        arrow buttons or ENT button to ACTIVATE LED display.
2. Press       arrow buttons again to CHOOSE desired PROGRAM STEP.
3. Press ENT button to ENTER desired PROGRAM STEP.

    (LED display number will blink after ENT button has been pressed).
4. Press       arrow buttons to choose SELECTION NUMBER for desired function of program step.
5. Press ENT button to program SELECTION NUMBER for desired function of program step.

    (Function has now been programmed into board).
6. Press ENT button again to exit programming OR after 10 seconds, board will automatically exit programming.
Note: Repeat these steps for all other desired programming functions.

Each tracker expansion board will have to be INDIVIDUALLY programmed with desired functions.

Basic Programming Sequence on EACH Tracker Expansion Board

Manage the Complete Access Control System from Your PC

SOFTW

ARE

INST

ALLE

D

7

8

9

4

5

6

1

2

3

0

OPER

WXYZ

TUV

PQRS

MNO

JKL

GHI

DEF

ABC

SP

CALL

Z

A

TELEPHONE ENTRY SYSTEM

HOLD TO SCAN

OPERATING INSTRUCTIONS

Use “A to Z” Buttons to Locate
Name and Code Number on Display.
Names are In Alphabetical Order.
To Call, Enter Code Number on
Keypad or Press “Call” Button. If
Line is Busy, Press “#” or “Call” to
Hang Up. Try Again.
Enter on Open Display and Tone.

1.

2.

3.

Refer to the DKS Remote 

Account Manager Software 

to program and manage the 

complete system.

Board addresses MUST be 

set for each board used.

Relay jumpers MUST be 

set for each relay used.

Programming Options on EACH Tracker Expansion Board

Board Power

16.5 VAC, 20 VA

Required

Your PC connected to the access control system. 

Either IM Server OR TCP/IP OR RS-232 OR Modem 

to Modem Connection. See PC Programmable 

Telephone Entry and Access Control Systems 

Installation/Owner’s manual for more information 

about connection options.

Com
Data 1
Data 0

(-) 12VDC
(+) 12VDC

Data 0
Data 1

Com

12 VDC

Battery

Back-Up

IMPORTANT Display Decimal Point Note

When decimal point is displayed: 

Indicates that you are SELECTING 

a program step.

When decimal point is NOT displayed: 

Indicates that you are IN a program step.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

00 - 99

00 - 99

00 - 99

00 - 99

00 - 99

0 or 1

0 or 1

0 or 1

0 or 1

0 or 1

0 or 1

0 - 12

0 - 4

5

0 or 1

00

01 - 99

00

01 - 99

00

01 - 99

00

01 - 99

00

01 - 99

0

1

0

1

0

1

0

1

0

1

0

1

0

1

2

3

4

5

6

7

8

9

10

11

12

0

1

2

3

4

5

Program

Step

Factory

Default

Description

Options

Selection

Number

Function

Door Strike Timer

Free Exit Timer, Strike Time

Door Ajar Timer

Aux Relay Timer

Free Exit Timer, Aux Relay

Free Exit, No Strike

Not Used

Door Contact Switch Logic

Auto Relock

Beeper / LED Hold Open

Hold Open or Hold Egress functions

Dual Door Mode

Not Used

Not Used

Aux Relay Functions

Alarm Relay Functions

Not Used

Not Used

Reset to Factory Defaults

View RF POT Setting

View RF Signal Loss

Card Code Forwarding

01 - 1 second

 

 

01 - 1 second

 

 

12 - 60 secs

 

 

12 - 60 secs

 

 

01 - 1 second

 

 

1 - Activate

 

0 - N.O.

0 - Disabled

 

 

 

0

 

 

0 - No relay

functions

0 - Disabled

 

 

 

 

 

 

 0 - Disabled

 

0 - Disabled

 

 

 

 

 

 

 

 

 

 

 

 

0 - Off

Adjustable Setting

Displays on LED

Door Operation Note:

PROPER Condition:

 The access control 

system OR request to exit device HAS 

activated the OUTPUT RELAY on the 

tracker expansion board and the door 

contact switch is CLOSED (Door is 

OPEN). This indicates that the door has 

been PROPERLY OPENED.

FORCED Condition: 

The access control 

system OR request to exit device has 

NOT activated the OUTPUT RELAY on 

the tracker expansion board and the 

door contact switch is CLOSED (Door is 

OPEN). This indicates that the door has 

been FORCED OPENED.

Sets Strike Time for output relay (term 25 & 26)

0.25 second strike time

Strike time in 1-second increments

Set Strike Time for RX (Request to Exit) of output relay (input at term 18)

0.25 second Egress Strike time

Egress Strike time in 1-second increments

Timer starts when valid access has been granted.

1 second Door Ajar Timer

Timer set in 5-second increments: 01 = 5 seconds,  10 = 50 seconds

Timer setting for Aux Relay activation in 5-second increments

1 second Door Ajar Timer

Timer set in 5-second increments: 01 = 5 seconds,  10 = 50 seconds

Set Strike Time for RX (Request to Exit) of Aux relay  (ONLY available if Dual Door Mode step 12 is ON)

0.25 second Egress Strike time

Egress Strike time in 1-second increments

Set RX (Request to Exit) function.  Activate Output Relay or do not Activate Output Relay

Do Not Activate Output Relay or Reader Beeper/LED when RX input is received

Activate Output Relay and Reader Beeper/LED for Free Exit Strike Time when RX received

Sets type of Door Switch contacts

N.O. contact from door switch with Door Closed (Circuit Open - CO)

N.C. contact from door switch with Door Closed (Circuit Close - CC)

Turns on Auto Relock function  (not available if Dual Door Mode, step 12 is ON)

Output Relay is activated for Strike Time

Door Contact Switch required.  If door returns to closed position during Strike Time

door will “relock” after 1 second, even if strike time has not expired.

Sets how BEEPER or LED will function during Hold Open

When Hold Open occurs, Beeper or LED is active only during Strike Timer

When Hold Open occurs, Beeper or LED will remain active during Hold Open 

Sets how Aux & Alarm Relay responds during Hold Open or Hold Egress situation

No Aux Relay functions.  Alarm will be in “Reset”.  If Alarm Relay is set for “integral” mode, Alarm relay will not activate.  If 

Alarm Relay set for “Bypass” mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold.

Aux Relay will function for all settings.  If Alarm Relay is set for “integral” mode, Alarm relay will not activate.  If Alarm Relay set 

for “Bypass” mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold.

Sets Tracker to function as 2 Access Points (2 tracker addresses)

Disabled, Tracker functions as single access point

Dual Mode: Tracker functions as set board address and next sequential address

Card Read will be sent to controller as set board address, access is granted or denied

Card then sent as set a1, access granted or denied.  Aux Relay becomes 2nd output relay.  All other Aux Relay functions 

disabled. Door Contact switch becomes RX (Request to Exit) for 2nd address.

Sets function for Aux Relay

Aux Relay Disabled

No Door Ajar Timer:  Requires Door Contact Switch.  Aux Relay activates when Door Not Closed.

No Door Ajar Timer, Pulse:  Requires Door Contact Switch.  Aux Relay “pulses” when Door Not Closed.

Door Ajar Timer:  Requires Door Contact Switch.  When door opens, start Door Ajar Timer.  When timer expires Aux Relay 

activates for Aux Relay timer or until door closes, whichever occurs first.

Door Ajar Timer, Pulse:  Requires Door Contact Switch.  When door opens, start Door Ajar Timer.  When timer expires Aux Relay 

Pulses for Aux Relay timer or until door closes, whichever occurs first.

Door Ajar, Pulse warning the ON: Requires Door Contact Switch.  When door opens, Pulse Aux Relay and start Door Ajar Timer.  

When timer expires Aux Relay ON for Aux Relay timer or until door closes, whichever occurs first.

Door opens for any reason, Start Door Ajar timer and pulse Aux Relay. When Door Ajar timer expires, start Aux Timer and 

continue Pulsing Aux Relay.

When Door Closes or both timers expire, turn off Aux Relay

Aux Relay as 2nd Alarm Relay.  Aux Relay will mirror Alarm Relay functions.

Aux Relay as 2nd Alarm Relay, PULSE.  Aux relay will Pulse during any Alarm Relay activation.

Good Card:  Aux Relay will activate for Aux Relay timer for any Access Granted Card

Any Card:  Aux Relay will activate for Aux Relay Timer when any card has been presented.

Bad Card:  Aux Relay will activate for Aux Relay timer when a card has been denied

Warn before Hold Open or Release of Hold Open:  Aux relay will activate for Aux Relay timer when scheduled Hold Open begins 

or ends.  Output Relay will be delayed until Aux Timer expires.  DO NOT set Aux Timer above 60 seconds in this mode.

Sets function for Alarm Relay

Aux Relay Disabled

Bypass Mode:  Alarm Relay provides “Bypass” to Alarm Door Switch.  With proper door input (access or egress) activate Alarm 

Relay, start Strike timer and Door Ajar timer.  When Door Ajar timer expires, deactivate Alarm Relay.

If second Door Contact Switch is provided, generate transaction for Door Ajar and Door Closed following Door Forced condition.  

Also generate transaction for Door Forced condition.

Integral Mode, Door Ajar Timer:  Door Contact Switch connected to Tracker, Alarm Relay provides connection directly to Alarm 

System.  When door is opened for any reason, start Door Ajar timer.  When Door Ajar timer expires and Door is still OPEN, 

activate Alarm Relay.  Reset when door closes.  

Send Door Ajar and Door Close transactions.

Integral Mode, Proper and Forced condition:  Door Contact Switch connected to Tracker, Alarm Relay provides connection 

directly to Alarm System. With proper door input (access or egress) start Strike timer and Door Ajar timer.  When Door Ajar 

timer expires and Door is still OPEN, activate Alarm Relay.  Reset when door closes. 

 If door is opened without proper condition, activate alarm relay.  When door closes deactivate Alarm Relay. Send Door Ajar, 

Door Close and Door Forced transactions.

Gate Alarm Function:  Alarm Relay will activate for 1 second when tracker board receives a “Gate Forced” or “Gate Obstructed” 

transaction from the operator control board.

Sets all parameters to Factory Default

Sets maximum amount of allowable signal strength loss

Displays current signal loss between Base and Tracker.

Sets Wireless Tracker to act as Repeater

ONLY USE AS DIRECTED BY DOORKING TECH SUPPORT 0=Repeater Mode OFF  1=Repeater Mode ON

Rev-E 1-13-14

QUICKSTART PROGRAMMING OPTIONS ON EACH HARDWIRED TRACKER EXPANSION BOARD GUIDELINES

Отзывы: