1.1.2  Surface Mount Units with Recess Box 

Surface mount units can be semi-flush mounted into a wall or pilaster by using the optional recess-
mounting box (p/n 1803-150).  Be sure the unit is mounted securely and is not subject to vibration 
from closing doors or gates.   

CAUTON!

  If this entry system is used to control a vehicular gate with an automatic gate operator, the 

entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or 
in such a way that a person cannot operate the entry system and touch the gate or gate operator at 
the same time. 

.5

3.625

2.25

4.875

8.375

11.0

13.25

15.25

2.125

11.125

15.00

2.125

3.375

12.0

13.25

2.2

5.75

9.3

11.5

2.0

2.68

8.812

1.06

.5

1.375 DIA

.25 DIA

10-24 x 1.25 STUD

.25 DIA

.25 DIA

Surface Mount
Entry System

1803-150
Recess Box

 

11 

Содержание 1803PC

Страница 1: ...le Telephone Entry Systems Owner s Manual DoorKing Inc 120 Glasgow Avenue Inglewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 www doorking com P N 1815 065 REV J 3 01 Copyright 2001 DoorKing Inc All rights reserved ...

Страница 2: ...2 ...

Страница 3: ... to make changes in the products described in this manual without notice and without obligation of DoorKing Inc to notify any persons of any such revisions or changes Additionally DoorKing Inc makes no representations or warranties with respect to this manual This manual is copyrighted all rights reserved No portion of this manual may be copied reproduced translated or reduced to any electronic me...

Страница 4: ... 2 Weigand Data Terminals 22 2 2 3 Elevator Control Terminals 23 2 2 4 RS 232 Terminals 23 2 3 Relay Wiring Typical 2 3 1 Controlling a Single Door or Gate 24 2 3 2 Controlling a Gate and a Pedestrian Gate or Door 25 2 3 3 Controlling a Gate Operator and Two Pedestrian Doors or Gates 26 2 3 4 Tracker Expansion Board Control 27 Section 3 Programming 3 1 General Programming Information 3 1 1 Program...

Страница 5: ...7 Four digit Entry Codes 3 7 1 Programming Four digit Entry Codes 48 3 7 2 Delete Four digit Entry Codes 48 3 7 3 Entry Code Ranges 48 Section 4 Adjustments Circuit Board Adjustments 49 1815 Adjustment Locations 51 1817 Adjustment Locations 52 Section 5 Operating Instructions 5 1 Guest Instructions 53 5 2 Resident Instructions 5 2 1 Responding to a Guest Call 54 5 2 2 Using an Entry Code 54 5 3 Sy...

Страница 6: ...be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal me...

Страница 7: ... the high forward reach to the system is over an obstruction of greater than 20 inches but less than 25 inches the maximum high forward reach allowed is 44 inches above grade to the top of the keypad 4 If the clear floor space allows parallel approach by a person in a wheelchair the maximum high side reach shall be 54 inches above grade to the top of the keypad 5 If the high side reach is over an ...

Страница 8: ...its own backup power source to retain memory during power outages 31 security levels total security level 00 always denies entry security level 01 always admits entry with 29 programmable security levels each with four time zones allows you to control and restrict user access as needed 10 programmable area codes allow the system to be used in areas requiring 10 and 11 digit dialing Three internal ...

Страница 9: ... gently pulling it out of the main terminal edge connector CAUTION the circuit board contains static sensitive components Discharge any static electricity from your hands by touching a proper ground device before removing the circuit board Place the circuit board where it will not be damaged 4 Mount the cabinet of the telephone entry system Be sure that mounting screws do not protrude into the cab...

Страница 10: ...ject to vibration from closing doors or gates CAUTON If this entry system is used to control a vehicular gate with an automatic gate operator the entry system must be mounted a minimum of ten 10 feet away from the gate and gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time 2 5 1 625 875 DIA 11 25 13 0 3 25 4 75 9 0 11 0...

Страница 11: ...sed to control a vehicular gate with an automatic gate operator the entry system must be mounted a minimum of ten 10 feet away from the gate and gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time 5 3 625 2 25 4 875 8 375 11 0 13 25 15 25 2 125 11 125 15 00 2 125 3 375 12 0 13 25 2 2 5 75 9 3 11 5 2 0 2 68 8 812 1 06 5 1...

Страница 12: ...ecurely and is not subject to vibration from closing doors or gates CAUTON If this entry system is used to control a vehicular gate with an automatic gate operator the entry system must be mounted a minimum of ten 10 feet away from the gate and gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time 3 0 13 0 13 25 11 0 1 125...

Страница 13: ...ount installation kit has two parts the rough in box and the trim ring The rough in box is installed first 3 875 1 75 1 25 4 25 7 25 10 25 13 25 14 5 9 0 12 75 1 875 11 0 1 75 1 75 1 75 6 375 11 0 3 5 9 25 10 24 x 1 125 Stud 1 125 DIA 25 DIA 13 ...

Страница 14: ...ation from closing doors or gates CAUTON If this entry system is used to control a vehicular gate with an automatic gate operator the entry system must be mounted a minimum of ten 10 feet away from the gate and gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time 2 625 9 0 14 25 11 0 2 25 25 DIA 875 1 0 16 0 5 875 3 0 1 2...

Страница 15: ...to vibration from closing doors or gates CAUTON If this entry system is used to control a vehicular gate with an automatic gate operator the entry system must be mounted a minimum of ten 10 feet away from the gate and gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time 15 375 1 0 12 0 2 625 13 5 3 0 6 0 7 5 9 0 1 125 DIA...

Страница 16: ...e unit is mounted securely and is not subject to vibration from closing doors or gates CAUTON If this entry system is used to control a vehicular gate with an automatic gate operator the entry system must be mounted a minimum of ten 10 feet away from the gate and gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time 3 125 ...

Страница 17: ... handle is in the un locked position pointing up Be sure that power to the telephone entry system is off 2 Carefully insert the memory chip into the socket The small half circular indentation on the chip must be at the top CAUTION Installing the memory chip upside down will cause permanent damage to the chip Be sure that the memory chip is seated correctly in the socket 3 Move the lever on the chi...

Страница 18: ...tallation of the postal lock Prior to installation of the postal lock be sure power to the telephone entry system is turned off 1 Remove the hole plug on the faceplate of the telephone entry system 2 Cut the wire tie wrapped around the micro switch next to the postal lock access hole 3 Remove the two hex nuts from the postal lock mounting studs Mount the postal lock on the two studs and secure wit...

Страница 19: ...s are susceptible to noise and hum pickup therefore it is preferable that you keep power wire runs as short as possible This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static discharges during installation or use Discharge any static prior to removing the circuit board from the lobby panel by touching a proper ground device Proper gr...

Страница 20: ...d Power 20 18 19 13 14 15 16 17 8 9 10 11 12 3 4 5 6 7 1 2 Power Wiring Maximum Distance 100 Feet 18AWG 200 Feet 16 AWG Phone Wiring Maximum Distance 800 Feet 24 AWG 1600 Feet 22 AWG Weigand Wiring Maximum Distance 500 Feet Belden 9931 500 Feet Consolidated 5324 CL Elevator Control Maximum Wiring 500 Feet Belden 9931 500 Feet Consolidated 5324 CL 20 ...

Страница 21: ...er 20 VA minimum for 1803PC and 1815 40 VA minimum for 1817 100 ft maximum with 18 AWG wire 200 ft maximum with 16 AWG wire Do not run high voltage 115 V power lines and communication lines in the same conduit These should be in separate conduits at least six 6 inches apart Be sure that all phone line wiring is twisted and completely isolated from ground Use only the supplied 16 5 VAC or U L liste...

Страница 22: ... For example a weigand card reader may have lights built into the housing that will require 16 VAC power for the lights to illuminate Do not power any other devices electric strikes magnetic locks etc from this power source Maximum wire run for weigand data is 500 feet using Belden 9931 Consolidated 5324 CL or equivalent six 6 conductor shielded wire Do not use twisted pair with weigand format Flo...

Страница 23: ...the PC programmable telephone entry system 2 2 4 RS 232 Terminals The PC programmable telephone entry system may be programmed using the RS 232 serial communication terminal This terminal allows a direct connection to a computer using a standard DB 9 serial connector on one end and loose wires on the other that connect to the RS 232 terminals on the board You can order a 6 foot cable from DoorKing...

Страница 24: ...ectric strike and magnetic lock are each powered by their own power supply Electric strikes are connected through the normally open NO contact and magnetic locks are connected through the normally closed NC contact 13 14 15 16 17 Relay 0 Relay 2 COM Relay 2 Relay 1 COM Relay 1 NO Relay 1 NC OR OR Gate Operator Electric Strike Magnetic Lock Relay 0 NC Relay 0 NO Relay 0 COM 24 ...

Страница 25: ...etic lock are powered from their own power supply The relay 2 contact is set to either normally open NO for electric strikes or normally closed NC for magnetic locks by placing the relay 2 contact shorting bar on either the NO or NC pins A variation of this diagram is for the system to control two doors or two gates 13 14 15 16 17 Relay 0 Relay 2 COM Relay 2 Relay 1 COM Relay 1 NO Relay 1 NC AND O...

Страница 26: ...e magnetic lock are powered from their own power supply The relay 2 contact is set to either normally open NO for electric strikes or normally closed NC for magnetic locks by placing the relay 2 contact shorting bar on either the NO or NC pins A variation of this diagram is for the system to control three doors or two gate operators entry and exit and a door or three gate operators 13 14 15 16 17 ...

Страница 27: ... 0 is used to control the gate operator and relays 1 and 2 are connected to the tracker expansion boards The relay 2 shorting bar is set for normally open NO contacts For more information on Tracker expansion boards and wiring refer to the Tracker Board Installation Manual P N 2351 065 13 14 15 16 17 Relay 0 Relay 2 COM Relay 2 Relay 1 COM Relay 1 NO Relay 1 NC Relay 0 NC Relay 0 NO Relay 0 COM To...

Страница 28: ...28 ...

Страница 29: ...terminals also the Tracker board input terminals can only cause R 1 or R 2 to activate Weigand input devices cannot cause R 0 to activate Therefore if Tracker expansion boards are used with this system R 0 must be designated as the PRIMARY relay and R 1 and R 2 are then designated as Tracker board command CMD relays with R 2 controlling tracker boards 1 through 8 system relays 3 10 and R 1 control...

Страница 30: ...ng any programming from the keypad This listing will provide you with the information needed to complete the manual programming sequence This symbol _ in the programming steps indicates numbers that you will need to enter one number per symbol When programming from the keypad after each programming step is performed correctly a short tone beep will be heard When the programming session is ended a ...

Страница 31: ...e tag on the small chip If the tag does not indicate MP the chips are standard chips and the system will not have advanced feature capabilities The table below list the valid numbers available with each memory level 500 500 MP Standard Chip MemPLUS Chip System Memory Phone Number Capacity Name Capacity Entry Code Capacity Device Code Capacity 25 25 25 25 625 75 75 75 75 1875 125 125 125 125 3125 2...

Страница 32: ...le from the software and must be turned ON or OFF at the system keypad 3 2 3 3 2 1 Master Code This programming step sets the system MASTER CODE The master code is the four digit number required to gain access to the system memory You need to know the master code prior to programming the system with the PC or to perform any of the programming functions on the following pages NOTE The master code c...

Страница 33: ...een programmed in the preceding steps Control Board Series Master Code enter number Memory Size circle one Memory Chip circle one Single Multiple circle one 40E enhanced 25 75 125 250 500 1000 2000 3000 MemPLUS STANDARD SINGLE MULTIPLE STOP If the telephone entry system is to be programmed from a PC no other programming is required at the system itself Complete the chart in section 3 2 4 as this i...

Страница 34: ...1 or 2 to set relay 2 strike time 3 Enter the two digit strike time _ _ 00 99 then press beep 4 Repeat steps 2 and 3 to set other relay strike times 5 Press 0 TOGETHER to end this programming step beeeeeep 3 3 2 Talk Time This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the resident The talk time can be set from 1 second up to 255 seco...

Страница 35: ...to set the other relays tone open numbers 5 Press 0 TOGETHER to end this programming step beeeeeep DIGIT FUNCTION 1 Momentary activation Relay will activate for the programmed strike time 3 3 1 2 Relay hold Relay will activate and remain activated until commanded to release 3 Relay release Deactivates the relay hold command 4 Relay hold 1 hour Relay will activate for 1 hour and then will automatic...

Страница 36: ...tary telephone The system can be programmed so that only one relay will activate or any combination of relays will activate HINT The relay that you designate as the primary relay should be programmed to activate from a rotary 9 command To cause a relay to activate enter a 1 in it s respective character slot or enter a 0 to not activate the relay Any combination of 1 s or 0 s is permissible For exa...

Страница 37: ...essing it a third time will display the third letter and pressing it a fourth time will display the number or fourth letter Example using the number 6 key MNO 6 Press one time to display the letter M Press two times to display the letter N Press three times to display the letter O Press four times to display the number 6 The chart below provides the sequence required to enter each letter and numbe...

Страница 38: ...1 12 13 14 15 16 17 18 19 20 Block 1 Block 2 Block 3 After organizing the user message in the matrix above follow the instructions below to enter the message into the system After each desired letter number or space is displayed on the directory remember to press to enter that character Spaces count as a character and must be entered into memory as a character After a complete block has been enter...

Страница 39: ...k 3 Block 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Block 1 After organizing the instruction message in the matrix above follow the instructions below to enter the message into the system After each desired letter number or space is displayed on the directory remember to press to enter that character Spaces count as a character and must be entered into memory as a character After a comp...

Страница 40: ... 9 10 11 12 13 14 15 16 17 18 19 20 Block 1 Block 2 Block 3 Block 4 After organizing the user message in the matrix above follow the instructions below to enter the message into the system After each desired letter number or space is displayed on the directory remember to press to enter that character Spaces count as a character and must be entered into memory as a character After a complete block...

Страница 41: ...3 Block 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Block 1 N K E Y P A D B U S Y P R E S S Block 4 A N Y K E Y T R Y A G A I N After organizing the instruction message in the matrix above follow the instructions below to enter the message into the system After each desired letter number or space is displayed on the directory remember to press to enter that character Spaces count as a cha...

Страница 42: ...ic directory remember to press after each desired letter number or space is displayed on the LCD When the entire name is displayed on the directory press again to enter the entire name into the directory If you make a mistake simply press to clear the display and start over Names cannot be more than 15 characters in length spaces count as a character The example below shows the keypad sequence to ...

Страница 43: ...rectory code length that you desire as described in 3 5 1 Changing the directory code length after programming the telephone numbers will erase all the numbers and directory codes that have been programmed To program phone numbers that will be referenced to an area code long distance calls and 10 digit calling follow the instructions under Long Distance Phone Number Programming on the next page If...

Страница 44: ...area codes 5 Press 0 TOGETHER to end this programming step beeeeeep 3 5 4 Programming Phone Numbers with Area Code Reference In this section phone numbers that are referenced to an area code long distance and 10 digit dialing calls will be programmed Be sure that the area code s have been programmed as described in the preceding section NOTE If long distance or 10 digit dialing is not required pro...

Страница 45: ... 6 Repeat steps 2 3 4 and 5 to enter additional names 7 Press 0 TOGETHER to end this programming step beeeeeep 3 5 6 Deleting Individual Phone Numbers This programming sequence is used to delete a single phone number under a known directory code Proceed to 3 5 7 to delete the resident name 1 Press 01 and enter the four digit MASTER CODE _ _ _ _ beep 2 Enter the directory code 1 2 3 or 4 digits dep...

Страница 46: ...ber was programmed under directory code 271 This programming sequence will not allow you to delete phone numbers 1 Press 06 and enter the four digit MASTER CODE _ _ _ _ beep 2 Enter the directory code 1 2 3 or 4 digits depending on what was programmed in 3 5 1 then press beep 3 The phone number programmed under the directory code entered in step 3 will be displayed on the LCD If C C C C C C C is d...

Страница 47: ...70 and enter the four digit MASTER CODE _ _ _ _ beep 2 Enter the directory code that the device code is to be assigned to 1 2 3 or 4 digits depending on what was programmed in 3 5 1 then press beep 3 Enter the five digit device code _ _ _ _ _ then press beep 4 Repeat steps 2 and 3 to enter additional device codes 5 Press 0 TOGETHER to end this programming step beeeeeep 3 6 2 Deleting Device Codes ...

Страница 48: ...peat steps 2 and 3 to delete more entry codes 5 Press 0 TOGETHER to end this programming step beeeeeep 3 7 3 Entry Code Ranges Four digit entry codes can be made to activate relay 0 relay 1 or relay 2 or any combination of relays by programming HI and LOW ranges for each relay Ranges may overlap which will cause more than one relay to activate if this is desired For example if the low boundary for...

Страница 49: ...t with a rotary dial type phone After they answer ask the resident to dial 9 while you adjust the click sensitivity potentiometer the resident may have to dial 9 several times for you to obtain the correct adjustment When the door or gate opens this is the correct adjustment for the click sensitivity 3 NOTE Adjusting the click sensitivity too high potentiometer fully clockwise could cause the syst...

Страница 50: ...t be installed to allow the system to answer any calls placed to it If remote programming or remote relay operation is to be used the shorting pin must be installed Removing the shorting pin will cause the system to never answer any call placed to it 4 9 Relay 2 Contact Pin 1 This shorting pin sets the contacts on relay number two to be set to either Normally Open NO or Normally Closed NC The pin ...

Страница 51: ...1815 Adjustment Locations SEC LEVEL CLICK SENS VOLUME FEEDBACK MASTER CODE RING PIN RLY 2 AUTO 1816 HF HS CONTRAST 51 ...

Страница 52: ...1817 Adjustment Locations SEC LEVEL CLICK SENS VOLUME FEEDBACK MASTER CODE RING PIN RLY 2 AUTO 1816 HF HS BACK LIGHT CONTRAST UPPER CONTRAST LOWER 52 ...

Страница 53: ... find the code assigned to the person they wish to visit 1803PC Systems Guest must check the separate directory listing to locate the person they wish to visit to find their assigned directory code 1815 Systems Guest can use the A and Z buttons to locate the name in the directory Once the residents name is displayed the guest presses the CALL button and the system will connect to the resident s te...

Страница 54: ...rogrammed talk time expires or until it detects dial tone Some newer type telephones emit a short tone rather than a continuous tone when their keys are pressed This may cause the telephone entry system to not respond to the tone open number If this happens simply press the tone open number twice in rapid succession to open the door or gate If a resident is using rotary dial telephone they will gr...

Страница 55: ...ds are connected to the system This command will cause ALL tracker boards connected to the telephone entry system to open or unlock the gate or door that they are controlling and will remain in this state until commanded to return to normal operation This feature is useful when management wants to open all gates or unlock all doors perhaps during an emergency situation as an example NOTE Hold open...

Страница 56: ...vated beep beep beep pause beep beep beep pause 4 Press the programmed tone number _ to deactivate the relay beep The system will automatically hang up 5 3 4 Time and Date Check This operating functions lets you check the current date time and day of the week that the system is currently programmed to If the calendar chip in the system is not programmed the system will emit a long beeeeeep when th...

Страница 57: ...ll activate their relay when the resident presses the tone open number 5 4 3 Connection to a PBX If the telephone entry system is going to be connected to a PBX system you may need to program extension numbers in place of a seven digit telephone number To do this enter the extension number and fill the remaining spaces with the key in the phone number programming step For example if the PBX system...

Страница 58: ...58 ...

Страница 59: ...problems persist and they cannot be corrected contact your authorized DoorKing dealer for assistance Before performing any trouble shooting check the following 1 Have a good VOM meter handy to check voltages and continuity 2 Have a telephone test set DoorKing p n 1800 050 or equivalent to check the telephone line Noise on the phone line will cause problems with the entry system 3 Be sure that the ...

Страница 60: ...e ground terminal 3 is not used as a low voltage common Check for excessive voltage drop on 16 VAC power Ringing or howling from the speaker Feedback improperly adjusted 4 2 Volume is set too high 4 1 After dial out dial tone is heard on the speaker Phone line is a rotary dial line Have the phone company change it to a touch tone line Door strike locks on Excessive voltage drop on 16 VAC line Usin...

Страница 61: ...emory size chip All data in the main memory will be erased when this function is performed Press 2 to cancel out of this function LCD display shows Need 1815 17 SM MEMCHIP The small chip in the PC board socket is for an 1818 system and cannot be used in the telephone entry system LCD is unreadable Adjust contrast 4 4 4 5 and 4 6 6 1 1 RS 232 Test This test procedure will check the RS 232 hardware ...

Страница 62: ...elay and then all the odd numbered relays then all the even numbered relays on the elevator control board s This test confirms communication between the telephone entry system circuit board and the elevator control board s 1 Press 76 and enter the four digit master code _ _ _ _ beep 2 The display will show WHICH ELEVATOR 1815 1817 systems only 3 Enter the elevator shaft number 1 2 3 or 4 _ then pr...

Страница 63: ... then press beep The display will show FLOOR 1815 1817 systems only 3 Enter the two digit floor number _ _ then press beep 4 The relay LED on the elevator control board that represents the floor number entered will turn ON for approximately 1 second 5 To check other floor relays repeat steps 2 and 3 6 When complete with the testing press 0 TOGETHER to end this testing sequence NOTE This program te...

Страница 64: ...oose neck mounting post with concrete base plate for pad mounting P N 1200 047 Telephone Test Set Includes clips cord and carrying case P N 1800 050 Battery 12 volt 8 amp hour gel cell provides stand by power during power interruptions P N 1801 008 Tracker Boards Tracker expansion boards P N 2351 010 allow the 1815 1817 system to operate up to sixteen individual doors or gates provides door ajar a...

Страница 65: ...to this resident 3 5 3 DIR is the resident s unique directory code and can be 1 to 4 digits 3 5 1 Enter the resident s four digit entry code 3 7 1 in the ENT field if they are used Enter the resident s unique device code 3 6 1 in the DEVICE field if access control devices Transmitters cards etc are used Enter the SEC LEVEL Security Level FL Floor and ER Elevator Reference numbers as required 6 3 L...

Страница 66: ...NAME AAC PHONE NUMBER DIR CODE ENT CODE DEVICE CODE SEC LEVEL FL ER Make additional copies of this table as needed 66 ...

Страница 67: ...our guest press on your touch tone telephone The telephone entry system will respond with a confirmation tone indicating that the door or gate is opening and will automatically disconnect itself Some newer telephones emit a very short duration tone when the number is pressed If your telephone does this you may have to press the open number twice in rapid succession to open the door or gate To deny...

Отзывы: