djpower TOPCAT HF-90 Скачать руководство пользователя страница 8

 

 

- 6 - 

Menu Page 

 

DMX address:

 

1

 

 

Setting DMX address 

1~512 

DMX MODE:

 

2CH

 

 

Switch between 2-channel or 6-channel mode 

2CH/6CH 

Tip switch

 

ON 

 

Setting the tilt protection 

(In case it is ON, if the machine tilts over 45° , it 
stops the unit from firing) 

ON/OFF 

Language

 

Chinese

 

 

Language setting 

 

Error and Warning 

Page 

 

E1: Pressure Err

  

 

P:0  V:12

 

 

Pressure failed to reach 100% after 13s pressurizing, 
system will report E1.  

Possible  fault:  No  fuel;  pump  failure;  pipeline 
problem etc. 

 

E2: Tip Err

      

 

P:0  V:12

 

 

The machine tilts over 45° , it stops running, system 
will report E2 

 

E3: 

Bat Err

        

 

P:0  V:12

 

 

Machine  stops  running  due  to  battery  voltage 
higher  than15V  or  lower  than  10V  for  5s 
contentiously. 

Possible fault: the battery is low. 

 

E4: 

System Lock

        

 

P:0  V:12

 

 

Safety lock located at TEST MODE 

 

E5: Relief Err           

 

P:0  V:12

 

 

Pressure  relief  error  due  to  pipeline  can't  release 
pressure. 

Possible fault: pressure release valve failure; pipeline 
problem or control system problem etc. 

 

5.3.3.

 

Menu Map Setup 

Press MENU to enter the setting interface. Press MENU to enter different options until you return to the main interface. 

5.4.

 

 Operation 

5.4.1.

 

Orientation 

Please read the safety distance print on the top panel of the FLAMER carefully. 

 

 

 

 

 

Содержание TOPCAT HF-90

Страница 1: ...HF 90 Machine Machine Machine Flame Flame Flame ...

Страница 2: ......

Страница 3: ...tructions from this manual Contact DJPOWER in case of doubts about the usage We assume that you your employees and others who use or come in contact with the machine are familiar with how the machine should be handled This includes proper use maintenance and repair of the machine as defined in this user guide This also means that employees are familiar with the use of machinery through training or...

Страница 4: ...er cable communication DMX cable should well connected and ensure the command keep at firing OFF status And safety lock stay at test mode The operator responsible for the control of Wave flame machine must always have a clear view of the device so that he she can stop the show immediately when there is danger The main AC power switch should near operator So that operator can turn off the power of ...

Страница 5: ... excellent atmosphere 2 2 Features Fast and high precision driving device and control system Fast and precise flame burst Rainproof design for the fuel nozzle thicken and anti rust metal structure durable in use Intelligent electronic control system Pressure no fluid monitoring Safety Failure warning Built in LCD control 3 pin and 5 pin DMX control Full set of SEETRONIC rainproof power connectors ...

Страница 6: ...Flame Machine HF 90 comes with a power input cord terminated with a Lockable power connector on one end The other end is CN plug CN market etc EU plug EU market etc US plug US market etc If the power input cord that came with your product has no plug or if you need the change the plug use the table below to wire the new plug Connection Wire China Wire Europe Wire U S AC Live Brown Brown Black AC N...

Страница 7: ...s the control panel functions use the four buttons located underneath the LCD display 5 3 On device Control Mode Operation 5 3 1 Programming Refer to the Menu Map to understand the menu options The menu map shows the main level and a variable number of programming levels for each option To go to the desired main level press MENU repeatedly until the option shows on the display This will take you t...

Страница 8: ...ilts over 45 it stops running system will report E2 E3 Bat Err P 0 V 12 Machine stops running due to battery voltage higher than15V or lower than 10V for 5s contentiously Possible fault the battery is low E4 System Lock P 0 V 12 Safety lock located at TEST MODE E5 Relief Err P 0 V 12 Pressure relief error due to pipeline can t release pressure Possible fault pressure release valve failure pipeline...

Страница 9: ...binet to avoid spilling ensure that the tube is placed in the fluid can tighten the container cap Please use the designated suitable fuels 4 Power and DMX cable connection 110V 220V main power supply See the item marked on the main label of the device 5 Switch ON the machine Please confirm safety lock located at TEST MODE before switch on the unit 6 Set DMX address The vertical flame machine can s...

Страница 10: ...Stop 5 4 3 2 2 channel mode Channel Function DMX Value Setting CH1 Ignition 0 253 No Fire 254 255 Start the ignition When the DMX value on this channel is higher than 253 the flame machine will ignite CH2 Mode 0 49 Pressure Relief Mode Emergency Stop 50 200 Compression Mode 201 255 Pressure Relief Mode Emergency Stop 6 MAINTENANCE 1 To maintain the system in good performance and running status it ...

Страница 11: ......

Страница 12: ......

Отзывы: