- 6 -
Menu Page
DMX address:
1
Setting DMX address
1~512
DMX MODE:
2CH
Switch between 2-channel or 6-channel mode
2CH/6CH
Tip switch
ON
Setting the tilt protection
(In case it is ON, if the machine tilts over 45° , it
stops the unit from firing)
ON/OFF
Language
Chinese
Language setting
Error and Warning
Page
E1: Pressure Err
P:0 V:12
Pressure failed to reach 100% after 13s pressurizing,
system will report E1.
Possible fault: No fuel; pump failure; pipeline
problem etc.
E2: Tip Err
P:0 V:12
The machine tilts over 45° , it stops running, system
will report E2
E3:
Bat Err
P:0 V:12
Machine stops running due to battery voltage
higher than15V or lower than 10V for 5s
contentiously.
Possible fault: the battery is low.
E4:
System Lock
P:0 V:12
Safety lock located at TEST MODE
E5: Relief Err
P:0 V:12
Pressure relief error due to pipeline can't release
pressure.
Possible fault: pressure release valve failure; pipeline
problem or control system problem etc.
5.3.3.
Menu Map Setup
Press MENU to enter the setting interface. Press MENU to enter different options until you return to the main interface.
5.4.
Operation
5.4.1.
Orientation
Please read the safety distance print on the top panel of the FLAMER carefully.
Содержание TOPCAT HF-90
Страница 1: ...HF 90 Machine Machine Machine Flame Flame Flame ...
Страница 2: ......
Страница 11: ......
Страница 12: ......