Nebelmaschine DF-V6C Art.No.: 115297 
 

3 / 13

 

1.

 

Safety instructions 

 

 

 

 

This device is suitable for indoor use (not outdoors) only.  

 

Unauthorized modifications will invalidate the warranty.  

 

Repairs are to carry out by skilled workers only.  

 

Use only fuses of the same type and original parts as spare parts.  

 

To avoid fire and electric shocks protect the unit from rain and humidity.   

1.1.

 

For safe and efficient operation 

Be careful with heat and extreme temperatures! 

Do not place the device in a location where it is exposed to extreme 

temperatures.  

Operate the device only in an ambient temperature between 0°C (32°F) - 

40°C (104°F). Do not expose the device to direct sunlight or heat sources.  

Keep away from humidity, water and dust!

 

Avoid placing the device in a location with high humidity or excessive 

dust. Place no liquids on or near the system. 

Place the device on a firm ground!

 

To avoid vibrations always place the device on a firm ground.  

Do not use chemicals for cleaning!

 

Use a clean and dry cleaning rag to remove dust. Metal parts can be 

cleaned with a damped cleaning rag.  Before cleaning always unplug the 

device from the power supply.  

If the device is not working properly!

 

If problems occur unplug the device from the power supply. The user should 

not try to service the device independently. All repairs and service must be 

performed by a qualified technician. 

Take proper care with the power cord!

 

Never pull the power cord to disconnect the device from the power 

supply, but remove the plug with plug housing in the hand. If you do not 

use the device for an extended period, unplug the device from the power 

supply. 

ATTENTION! 

Damages caused by the disregard of this user manual are not subject to 

warranty. The dealer will not accept liability for any consequent secondary 

failures. Only skilled workers are allowed to carry out the electrical 

connections.  All electrical and mechanical connections have to be carried 

out according to the European safety standards.  

 

Содержание DJV DF-V6C

Страница 1: ...Nebelmaschine DF V6C USERS MANUAL ...

Страница 2: ... 1 1 For safe and efficient operation 3 2 Intended use of the device 4 2 1 Electrical connections 5 3 Introduction 6 3 1 Item deliverd 6 3 2 Product description 6 4 Start up 7 4 1 Bedienung 7 4 1 1 Structure oft he menu 7 4 1 2 DMX chart 8 4 1 3 Wireless Remote 8 5 Technical data 9 ...

Страница 3: ...rations always place the device on a firm ground Do not use chemicals for cleaning Use a clean and dry cleaning rag to remove dust Metal parts can be cleaned with a damped cleaning rag Before cleaning always unplug the device from the power supply If the device is not working properly If problems occur unplug the device from the power supply The user should not try to service the device independen...

Страница 4: ...n contact with the device Make sure that during the installation and removal of the device the area below the place of installation is basically cordoned off This also applies to implementation of service Make familiar yourself with the functions of the device before start up People without the experience should not handle with the device The most cause of functional disorder is inappropriate hand...

Страница 5: ...vice which differs from usages which are described in this manual can cause damages of the device In this case the warranty expires Additional you should notice that every different usage is related with dangers and can cause e g an electrical short fire electric shock or crash 2 1 Electrical connections Connect the fixture to the mains with the enclosed power cable and plug The earth has to be co...

Страница 6: ...e read this manual carefully 3 1 Item deliverd 1x Fog machine DF V6C 1x Power cord IEC 1x Remote W 2 1x Receiver KT 1 Manual German English 3 2 Product description 1 Tank 2 Fluid tube 3 Handle 4 Fog button 5 Remote Wireless INPUT 6 XLR 3pol INPUT OUTPUT 7 Display Tank baffle 8 Nozzle 9 On Off Switch 10 Power supply IEC ...

Страница 7: ...ce starts to heat up This process needs 4 min meanwhile the display shows HEAT 4 The heating process is finished The display shows Addr 4 1 Bedienung The operation can be made by the display manual by using the fog button or with remote MENU For call up the structure of the menu and set the DMX value UP Increase a value DOWN Dicrease a value ENTER STOP Confirm the setting 4 1 1 Structure oft he me...

Страница 8: ...s Controller If you want to use several devices you can assign up to 4 devices to one remote by using the receivers 2 Dipswitches You can assign the receiver to different buttons or channels of the remote CH1 Dipswitch 1 On Dipswitch 2 4 Off CH2 Dipswitch 2 On Dipswitch 1 3 4 Off CH3 Dipswitch 3 On Dipswitch 1 2 4 Off CH4 Dipswitch 4 On Dipswitch 1 3 Off 2 Fog button 1 4 With the buttons CH1 CH4 y...

Страница 9: ...wer consumption max 1350W Fuse 8A 250 V Heating power 1350 W Heating time 4 min Tank volume 2 5 Liter Output volume 850 m min Fluid consumption 100 149 ml min DMX512 Yes Number of DMX channels 1 Remote Yes Frequency oft he remote 433 MHz Power in IEC Dimensions 366 x 340 x 195 mm Weight 7 kg ...