9 / 12
4. Fluid Sensor
The device hast two fluid tanks and also two pumps. If the fluid of one tank is empty the device
changes automatic (if the fluid sensor is activated) to the pump of the other tank. If one tank is empty,
the LED lights for 20s and the other pump starts, the LED goes out again. Is also the other tank the
LED lights up again and the display flashes and shows „No fluid“.
Note: For this function the fluid sensor has to been activated, how to activate it is described in chapter
3.4.
4.1. Reset the fluid sensor
4.1.1. Reset in manual control
-
Hold MANUAL, the pump starts.
-
After 20s the LED goes out and the warning message is deleted..
4.1.2. Reset in DMX control
-
Set channel 2 to value 0.
-
Set channel to a value >5.
-
Repeat these steps, until the LED goes out. .