dj power DSK-4000 Скачать руководство пользователя страница 9

 

9 / 12 

4.  Fluid Sensor 

 

The device hast two fluid tanks and also two pumps. If the fluid of one tank is empty the device 

changes automatic (if the fluid sensor is activated) to the pump of the other tank. If one tank is empty, 

the LED lights for 20s and the other pump starts, the LED goes out again. Is also the other tank the 

LED lights up again and the display flashes and shows „No fluid“. 

 

Note: For this function the fluid sensor has to been activated, how to activate it is described in chapter 

3.4. 

4.1. Reset the fluid sensor 

4.1.1.  Reset in manual control 

 

Hold MANUAL, the pump starts. 

After 20s the LED goes out and the warning message is deleted.. 

4.1.2.  Reset in DMX control 

 

Set channel 2 to value 0. 

Set channel to a value >5.  

Repeat these steps, until the LED goes out. . 

 

 

Содержание DSK-4000

Страница 1: ...Manual Fog machine DSK 4000...

Страница 2: ...ntrol panel 6 3 4 Menu 7 3 4 1 Interval set 7 3 4 2 Duration set 7 3 4 3 Set the fog output in timer mode 7 3 4 4 Set the fog output in volume mode 7 3 4 5 Fan Speed 7 3 4 6 Rotation plate speed 7 3 4...

Страница 3: ...a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoi...

Страница 4: ...plug when the unit is not in use This unit is for adults use only Keep away from children Never leave the unit running unattended Never aim the output nozzle directly at people The output smoke is ve...

Страница 5: ...ty and maintenance instructions to ensure the machine s normal work and prolong its usage life Open the shipping packing and check whether all the necessary accessories to operate the unit have arrive...

Страница 6: ...it out of the machine Liquids in the machine can cause short circuits and its danger to life and limb Do not overfill the tank 3 2 Start up 1 Connect the power cable with a power supply that meets th...

Страница 7: ...put volume from 1 100 You need this setting if you want to use the function TIMER 3 4 4 Set the fog output in volume mode Press FUNCTION until you can read Volume Out in the display Use UP DOWN to set...

Страница 8: ...Fazer S If the fluid sensor is deactivated the display readout Ready To Faze 3 5 DMX 3 5 1 DMX chart Channel Value from Value to Function 1 Fan speed 0 5 No function 2 6 255 Fan speed slow fast Outpu...

Страница 9: ...es out again Is also the other tank the LED lights up again and the display flashes and shows No fluid Note For this function the fluid sensor has to been activated how to activate it is described in...

Страница 10: ...echnical data Voltage AC 220V 240V 50 60Hz Fuse 15A 250V Power consumption 300W Output volume Ca 1 132 7m 3 Minute Heating time Ca 10min Tank volume 2x5l Weight 89kg Measurements 869 x524x895mm DMX ch...

Страница 11: ...11 12...

Страница 12: ...12 12 Importeur B K Braun GmbH Industriestra e 2 D 76307 Karlsbad info bkbraun com...