![DiyTracker MT-18 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/diytracker/mt-18/mt-18_users-manual-installation-and-operating-instructions_2511515006.webp)
Wiring
Diagram
6
Solder and insulate all connections (Crimping should be avoided wherever possible)
WARNING
GND
A.
Connect the Brown wire/cable to the yellow wire/cable (86) of the relay
B.
Connect the white wire/cable (85) of the relay to a constant 12/24v source
C.
Cut the positive wire of the ignition coil / fuel pump / solenoid etc
D.
Connect the green wire of the relay (30) to one end of the positive wire that you cut
E.
Connect the green wire of the relay (87a) to one end of the positive wire that you cut
Power cut relay
(Optional connection)
This connection is to remotely immobilise your bike. Please be cautious if installing
this optional immobiliser function as large currents are carried when starting the motorcycle
and we would hate for you to have an unplanned motorcycle stop due to an installation failure.
86
85
87a
30
Relay
GND
+12/24v
Bl ue
Black
Red
Yellow
Brown
Ignition Coil
Fuel Pump
Solenoid
Panic Button
All rights reserved. ©2011 DIY TRACK
86
85
87a
30
+12/24v
B
A
C
D
E
Relay