wireless sensors or wired ports trigger alarm(only the wireless detectors of Home Arm function effective, 

Out Arm detectors are ineffective), then dial out phone or send message, the light STATUS becomes 

red flashing. 

When  press  Disarm,  the  light  STATUS  becomes  green,  wireless  detectors  or  wired  ports  won’t 

trigger alarm. 

When press Alarm, regardless of the host in arming status (the light STATUS is green flashing),or 

disarming status (the light STATUS is green ), will make the host trigger alarm immediately , dial out 

phone and send message, the light STATUS becomes red flashing. 

 

How to record 10 seconds voice message ?     

Users  can  record  geographical  location,  home  address  information  as  alarm  voice,  which  will  be 

broadcast when alarming, convenient for the receiver to know the scene information. 

Recording operation: 

Press the record key for 2 seconds until the light Record is on, then speak by the microphone which 

embedded in the left side of the host, then 10 seconds’ voice can be record. 10 seconds later the light 

RECORD is off,

 

then exits the recording status automatically. If you want to change the voice content, 

repeat the operation. 

 
How to test the alarm function ? 

  When the host is powered and disarmed, users can use remote controller(

Out Arm

, Home Arm key ) 

or send message (123456#1#1#) to arm. Under arming status, the green light flash, If the wired input 

trigger alarm (any port of I1, I2, I3, I4, I5 shorted or disconnected to GND) or wireless sensors trigger 

alarm (wireless FIR detector, wireless door sensor, 

Out Arm

, Home Arm key of remote controller ),or 

calling in the system from other places trigger alarm (input password 123456 #, then 2 # 1 #), will make 

the host send alarm information. 

  If there are phone numbers stored to receive SMS, the host will send the corresponding SMS to the 

SMS users based on the trigger port

wired I1,I2,I3,I4,I5,wireless sensors 1-16

  If there are phone numbers stored to receive alarm, the host can dial every number to alarm. When 

replying, users can hear the alarm voice which recorded before. if the voice isn't clear, press “

” 

key to listen again. 

  When alarming

users can open the listening-in function or control in long-distance, no need to input 

the  password

pressing  2#1#  to  make  scene  alarm  immediately

pressing  2#0#  to  close  on-site 

alarm.   

  When alarming

users can open listening-in function or control in long-distance, no need to input 

password

pressing 3#1# to open listening-in

pressing 3#0# to close listening-in. 

  When alarming

users can talk to people at the scene, after the phone getting through, there is no 

need to input password

pressing 4#1# to make the host send out the voice of master immediately, 

pressing 4#0# to close the voice at the scene. 

  When alarming

after users get through the phone, if it is not the intrusion, users can dial 1#1# to 

make the host arm again, and the host will not go on dialing other phones. 

  When alarming

people at the scene can press the Disarm key to exit from alarm status. 

  Normal  use,  if  there  is  built-in  battery,  when  external  power  supply  is  off  /  on,  the  host  will  send 

messages to inform users. 

The message content :power change off/on(year/month/day, hour/minute/second) 

  Usually, users can remote control the host through phone, but input password first to continue other 

operation.   

Содержание BT-104GSM

Страница 1: ...Business Home GSM Alarm systems Installation and User Manual Profile For a better understanding of this product please read this user manual thoroughly before using it...

Страница 2: ...ent for users and alarm center to control the system work regularly 7 Can set 5 phone number Can set 5 groups of SMS number 8 Host power off warning function SMS to inform users if power failure 9 Int...

Страница 3: ...o ON at this time the external power will recharge the battery automatically Antenna You should connect antenna before insert the power supply How to power on Turn over the host to the bottom take out...

Страница 4: ...tening record 1 0 Disarm 1 1 Out Arm all arm 1 2 Home Arm part arm 2 0 Close scene siren sound 2 1 Open scene siren sound 3 0 Close monitor scene function 3 1 Open monitor scene function 4 0 Close int...

Страница 5: ...t is wrong Setting of the system time After host begin to work Send SMS password 31 Thus the system time will be same to the time of GSM base station Arm disarm timing function Eg Sending SMS password...

Страница 6: ...the detectors of external zones will be in arming status How to delete the lost sensors If the host needs to delete sensors in wireless zones FIR detector wireless door sensor remote controller and so...

Страница 7: ...rm key of remote controller or calling in the system from other places trigger alarm input password 123456 then 2 1 will make the host send alarm information If there are phone numbers stored to recei...

Страница 8: ...Technical parameter Static Current 50 mA Power Supply 9 12 V Working Temperature 10 55 Receive Coding ASK Receive Frequency 315 433MHz Remote Control Distance No obstacle 100m Detectors 16...

Отзывы: