Instruction & Operation Manual
800.789.1718
•
An isolation valve should be installed at both
the suction and discharge sides of the pump.
This will allow you to remove the pump for
preventative maintenance or repair without the
need to drain your system.
(see the diagram to the right)
•
If pump is not in a flooded suction condition,
install either a foot valve or system check valve
to insure pump volute is flooded for priming.
•
In order to provide pump flow rate control,
a control valve should be installed in the
discharge piping to prevent motor overload.
MINIMUM LENGTH
= 10 X DIAMETER
DIAMETER
CHECK
VALVE
CONTROL
VALVE
MINIMUM LENGTH = 8 X DIAMETER
DIAMETER
ISOLATION
VALVE
PSI
Installation
Piping: Valve location
All power must be off and locked out during the installation process.
Only registered electricians should do the electrical installation.
Electrical
•
Follow motor manufacturer’s installation procedures.
•
Verify motor nameplate data is compatible with existing
electrical supply.
•
Verify pump rotation. An arrow sticker is supplied
with every pump to show correct pump rotation. If the
arrow stickers are missing, contact Dixon Sanitary for a
replacement.
•
Correct rotation is counter clockwise when facing pump
inlet connection.