MAINTENANCE
The following wiring diagrams, as well as other motor specifications, can be accessed through the Marathon
Motors (Regal Beloit) website at
https://www.regalbeloit.com/Brands/Marathon-Motors
. Use the manufacturer’s part no. and/or Catalogue No. listed in the following table for reference.
POWER SOURCE SPECIFICATION
Type:
EP HP Hz PH Voltage Wired as Duty
FLA
RPM Switch Encl EP Class Dixon Pumps Part No. Manufacturer Man. Part No. Man. Cat. No.
AC Motor NO 1.5 60 1 115/230 115
C*
12.0/6.0
1725 On JB** TEFC
n/a
55-01010
Marathon 56B17F15504
n/a
AC Motor
YES
1.5 60 1 115/230 115
C
12.4/6.2
1725 On Motor EPFC
55-01020
Marathon 56B17G15502
n/a
Cl1 Grp D Div1 + Cl2 Grp F&G T3B *C = Continuous **JB = Junction Box