Check Operation 

 

1. Place elbow bottom end on service station adapter (elbow is 
designed for use with 4" top seal adapter only).  
 
2. 

Move operators handle to 11 o’clock the open/unclamped position.  

 
3. Release and hold the safety latch if equipped with one. Move the 
handle clockwise to 2 o’clock position for full clamping (lever cannot 
be moved any farther).  
 
3. Check locking arms on adapter. If the elbow is fitted with a safety 
latch, make sure the stem pin is in the latch notch, preventing 
movement of operating handle.  
 
4. 

Release by moving handle to 11 o’clock. If fitted with safety latch, 

lift the latch lever and operating lever at the same time. 
 

Care and Handling 

 

Dixon Bayco drop elbows are tested at the factory and are in proper 
working condition when shipped. Drop elbows are designed to be 
tough and to provide long service with reasonable care and handling. 
To ensure long service, Dixon Bayco elbows should not be thrown, 
dropped or dragged; such actions may compromise the integrity and 
reduce the service life of the product. 
 

Inspection 

 

Drop elbows can fail to operate if not properly maintained. If the 
6200X / 6500X elbow develops any problems, remove from service 
and contact your Dixon Bayco distributor describing the difficulty. The 
distributor will provide further instructions repair and warranty of the 
product.  
 
Elbows should be inspected monthly. Check the main gasket seal, 
the sight glass, and the flange where the base is attached to the 
elbow body for any signs of leakage. Change seals if necessary. 
Check the sight glass for cracks or damage and replace if needed. 
Check and tighten all fasteners periodically. Lubricate the lever stem. 
Check the bushings and replace if cracked or worn, and change if 
required. Check operation as per above. 

 
 