1.

 

GENERAL WARNING

1.1

 

PLEASE READ BEFORE USING THIS MANUAL

 

This manual is part of the product and should be kept near the instrument for easy and quick

reference.

 

The instrument shall not be used for purposes different from those described hereunder. It cannot

be used as a safety device.

 

Check the application limits before proceeding.

1.2

 

 SAFETY PRECAUTIONS

 

Check the supply voltage is correct before connecting the instrument.

 

Do not expose to water or moisture: use the controller only within the operating limits avoiding

sudden temperature changes with high atmospheric humidity to prevent  formation of condensation

 

Warning: disconnect all electrical connections before any kind of maintenance.

 

Fit the probe where it is not accessible by the End User. The instrument must not be opened.

 

In case of failure or faulty operation send the instrument back to the distributor or to “Dixell s.r.l.”

(see address) with a detailed description of the fault.

 

Consider the maximum current which can be applied to each relay (see Technical Data).

 

Ensure that the wires for probes, loads and the power supply are separated and far enough from

each other, without crossing or intertwining.

 

In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel

with inductive loads could be useful.

2.

 

GENERAL DESCRIPTION

Model 

XW35VS, 100x64 format,  is a microprocessor based controllers suitable for applications on

medium or normal temperature refrigerating units.

XW30VS is  provided with 3 relay outputs to control compressor, alarm  and the lights.

XW35VS is  provided with 3 relay outputs to control compressor, evaporator fans  and the lights.

It’s also provided with 2 NTC or PTC probe inputs, one for temperature control the second to display

temperature of another point.

An  output allows the user to programme the parameter list with the 

“Hot Key”.

3.

 

CONTROLLING LOADS

3.1

 

THE COMPRESSOR

The regulation is performed according to the temperature measured by the thermostat probe with a

positive differential from the set point: if the temperature increases and reaches set point plus differential

the compressor is started and then turned off when the temperature reaches the set point value again.

In case of fault in the thermostat probe the start and stop of the compressor are timed through

parameters “

COn” and “COF”.

3.2

 

FAST FREEZING

When defrost is not in progress, it can be activated the keypad by holding the 

o

o

 key pressed for about 3

seconds. The compressor operates in continuous mode for the time set through the “

CCt” parameter.

The cycle can be terminated before the end of the set time using the same activation key, 

o

o

 for about 3

seconds.

3.3

 

DEFROST

The defrost interval is control by means of parameter “

EdF”: (EdF=in) the defrost is made every “IdF

time, (EdF=Sd) the interval “IdF” is calculate through Smart Defrost algorithm (only when the compressor

is ON).

Defrost is performed through a simple stop of the compressor. Parameter “

IdF” controls the interval

between defrost cycles, while its length is controlled by parameter “

MdF”.

3.4

 

CONTROL OF EVAPORATOR FANS – ONLY FOR XW35VS

The fan control mode is selected by means of the “

FnC” parameter:

FnC=C-n  fans will switch ON and OFF with the compressor and not run during defrost:;

FnC= O-n fans will run continuously, but not during defrost

After defrost, there is a timed fan delay allowing for drip time, set by means of the “Fnd” parameter.

FnC=C-y  fans will switch ON and OFF with the compressor and run during defrost;

FnC=O-y  fans will run continuously also during defrost

4.

 

KEYBOARD

To display and modify target set point; in programming mode it selects a parameter or

confirm an operation.

By holding it pressed for 3s when max or min temperature is displayed it will be erased.

To see the max. stored temperature; in programming mode it browses the parameter codes

or increases the displayed value. By holding it pressed for 3s the fast freezing  cycle is

started.

To see the min stored temperature; in programming mode it browses the parameter codes

or decreases the displayed value.

By holding it pressed for 3s the defrost is started.

Switch ON and OFF the light of the cold-room

Switch ON and OFF the instrument.

KEY COMBINATIONS

 

To lock and unlock the keyboard.

 

To enter the programming mode.

 

To exit the programming mode.

4.1

 

USE OF LEDS

Each LED function is described in the following table.

LED

MODE

Function

ON

The compressor is running

FLASHING

- Programming Phase (flashing with LED 

)

- Anti-short cycle delay enabled

ON

The fan is running

FLASHING

Programming Phase (flashing with LED 

)

ON

The defrost is enabled

FLASHING

Drip time in progress

ON

The Fast Freezing cycle is enabled

ON

- ALARM signal

- In “Pr2” indicates that the parameter is also present in “Pr1”

ON

The light is on

4.2

 

HOW TO SEE THE MIN TEMPERATURE

1. 

Press and release the 

p

p

 key.

2. 

The “Lo” message will be displayed followed by the minimum temperature recorded.

3.

By pressing the 

p

p

 key or waiting for 5s the normal display will be restored.

4.3

 

HOW TO SEE THE MAX TEMPERATURE

1. 

Press and release the 

q

q

 key.

2. 

The “Hi” message will be displayed followed by the maximum  temperature recorded.

3.

By pressing the 

q

q

 key or waiting for 5s the normal display will be restored.

4.4

 

HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED

To reset the stored temperature, when max or min temperature is displayed :

1.

 

Press SET key until “rST” label starts blinking.

N.B. After the installation RESET the temperature stored .

4.5

 

HOW TO SEE AND MODIFY THE SET POINT

1.

Push and immediately release the 

SET key: the display will show the Set point value;