dIXEL
Installing and Operating Instructions
1592020570
1592020570 XR70CX RTC GB r1.0 28.05.2008.doc
XR70CX
5/5
Labe
Name Range
°C/°F
Level
ALU
MAXIMUM temperature alarm
Set
÷
110.0°C; Set÷230°F
110 Pr1
ALL
Minimum temperature alarm
-50.0°C
÷
Set/ -58°F
÷
Set
-50.0 Pr1
AFH
Differential for temperat. alarm recovery
(0,1°C÷25,5°C) (1°F÷45°F)
1
Pr2
ALd
Temperature alarm delay
0
÷
255 min
15 Pr2
dAO
Delay of temperature alarm at start up
0
÷
23h e 50’
1.3 Pr2
AP2
Probe for temperat. alarm of condenser
nP; P1; P2; P3; P4
P4
Pr2
AL2
Condenser for low temperat. alarm
(-55 ÷ 150°C) (-67÷ 302°F)
-40
Pr2
AU2
Condenser for high temperat. alarm
(-55 ÷ 150°C) (-67÷ 302°F)
110
Pr2
AH2
Differ. for condenser temp. alar. recovery [0,1°C ÷ 25,5°C] [1°F ÷ 45°F]
5
Pr2
Ad2
Condenser temperature alarm delay
0 ÷ 254 (min.) , 255=nU
15
Pr2
dA2
Delay of cond. temper. alarm at start up
0.0 ÷ 23h 50’
1,3
Pr2
bLL
Compr. off for condenser low
temperature alarm
n(0) - Y(1)
n Pr2
AC2
Compr. off for condenser high
temperature alarm
n(0) - Y(1)
n Pr2
tbA
Alarm relay disabling
n=no; y=yes
y
Pr2
oA3
Fourth relay configuration
ALr = alarm; dEF = do not select
it; Lig =Light; AUS =AUX;
onF=always on; Fan= do not
select it; db = do not select it;
dF2 = do not select it
ALr
Pr2
AoP
Alarm relay polarity (oA3=ALr) oP;
cL
cL
Pr2
i1P
Digital input polarity
oP=opening;CL=closing
cL
Pr1
i1F
Digital input configuration
EAL, bAL, PAL, dor; dEF; Htr, AUS
dor Pr1
did
Digital input alarm delay
0÷255min
15
Pr1
Nps
Number of activation of pressure switch
0 ÷15
15 Pr2
odc
Compress and fan status when open
door
no; Fan; CPr; F_C
F-c Pr2
rrd
Regulation restart with door open alarm
n – Y
y
Pr2
HES
Differential for Energy Saving
(-30°C÷30°C) (-54°F÷54°F)
0
Pr2
Hur
Current hour
0 ÷ 23
-
rtc
Min
Current minute
0 ÷ 59
-
rtc
dAY
Current day
Sun ÷ SAt
-
rtc
Hd1
First weekly holiday
Sun÷ SAt – nu
nu
rtc
Hd2
Second weekly holiday
Sun÷ SAt – nu
nu
rtc
ILE
Energy Saving cycle start during
workdays
0 ÷ 23h 50 min.
0
rtc
dLE
Energy Saving cycle length during
workdays
0 ÷ 24h 00 min.
0
rtc
ISE
Energy Saving cycle start on holidays
0 ÷ 23h 50 min.
0
rtc
dSE
Energy Saving cycle length on holidays
0 ÷ 24h 00 min.
0
rtc
Ld1
1
st
workdays defrost start
0 ÷ 23h 50 min. - nu
6.0
rtc
Ld2
2
nd
workdays defrost start
0 ÷ 23h 50 min. - nu
13.0
rtc
Ld3
3
rd
workdays defrost start
0 ÷ 23h 50 min. - nu
21.0
rtc
Ld4
4
th
workdays defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Ld5
5
th
workdays defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Ld6
6
th
workdays defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Sd1
1
st
holiday defrost start
0 ÷ 23h 50 min. - nu
6.0
rtc
Sd2
2
nd
holiday defrost start
0 ÷ 23h 50 min. - nu
13.0
rtc
Sd3
3
rd
holiday defrost start
0 ÷ 23h 50 min. - nu
21.0
rtc
Sd4
4
th
holiday defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Sd5
5
th
holiday defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Sd6
6
th
holiday defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
PbC
Kind of probe
Ptc; ntc
1 Pr2
Adr
Serrial address
1÷247
1 Pr2
onF
on/off key enabling
nu, oFF; ES
ntc
Pr1
dP1
Room probe display
--
nu Pr2
dP2
Evaporator probe display
--
--
Pr1
dP3
Third probe display
--
--
Pr1
dP4
Fourth probe display
--
--
Pr1
rSE
Valore set operativo
actual set
--
Pr2
rEL
Software release
--
--
Pr2
Ptb
Map code
--
--
Pr2
2
Only for models XR70CX–xx
2
xx, XR70CX–xx
3
xx; XR70CX–xx
6
xx; XR70CX–xx
7
xx