Installing and Operating Instructions

 

release  7.0

 

1. 

 GENERAL WARNING 

1.1  Please read before using this manual 

• 

This manual is part of the product and should be kept near the instrument for easy and quick reference. 

• 

The instrument shall not be used for purposes different from those described hereunder. It cannot be used 
as a safety device. 

• 

Check the application limits before proceeding. 

1.2 

 Safety Precautions 

• 

Check the supply voltage is correct before connecting the instrument. 

• 

Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden 
temperature changes with high atmospheric humidity to prevent  formation of condensation 

• 

Warning: disconnect all electrical connections before any kind of maintenance. 

• 

The instrument must not be opened. 

• 

Fit the probe where it is not accessible by the End User. 

• 

In case of failure or faulty operation send the instrument back to the distributor or to dIXEL s.r.l (see 
address) with a detailed description of the fault. 

• 

Consider the maximum current which can be applied to each relay (see Technical Data). 

• 

Ensure that the wires for probes, loads and the power supply are separated and far enough from each 
other, without crossing or intertwining. 

• 

In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with 
inductive loads could be useful. 

2. GENERAL DESCRIPTION 

Models 

XR160C

 and 

XR170C

, 32x74 mm format, are microprocessor based controllers suitable for 

applications on medium or low temperature refrigerating units. They are provided with three relay outputs to 
control compressor, defrost - which can be either electrical or hot gas  - and the evaporator fans. They are also 
provided with two PTC probe inputs, one for temperature control, the other to be located onto the evaporator 
to control the defrost termination temperature. 
Model 

XR170C

 also features an additional relay for the alarm output and an internal buzzer for acoustic signal.  

Models 

XR160D

 and 

XR170D

, DIN RAIL format, provide the same features as the correspondent 

XR160C

 

and 

XR170C

 models. Alarm conditions in model XR160D are also signalled by a 12V/40mA output. 

Models 

XR162C

 and 

XR172C

, matched with slave devices 

XR30SL

 and 

XR40SL

 respectively, provide the 

same features as 

XR160C

 and 

XR170C

Each instrument is fully configurable through special parameters that can be easily programmed through the 
keypad. 

3. CONTROLLING LOADS 

3.1 The compressor 

The regulation is performed according to the 
temperature measured by the thermostat probe 
with a positive differential from the set point: if the 
temperature increases and reaches set point plus 
differential the compressor is started and then 
turned off when the temperature reaches the set 
point value again. 
In case of fault in the thermostat probe the start 
and stop of the compressor are timed through 
parameters “

COn

” and “

COF

”. 

 

952057-58

 

XR160C - XR170C - XR160D - XR170D - XR162C - XR172C 

2/

י

 

 

Содержание XR160C

Страница 1: ...________________ 4 5 1 Function Menu_______________________________________________________ 4 5 2 List of functions ______________________________________________________ 4 5 3 Exit Timeout___________...

Страница 2: ...eful 2 GENERAL DESCRIPTION Models XR160C and XR170C 32x74 mm format are microprocessor based controllers suitable for applications on medium or low temperature refrigerating units They are provided wi...

Страница 3: ...ing defrost After defrost there is a timed fan delay allowing for drip time set by means of the Fnd parameter FnC 2 fans will switch ON and OFF with the compressor and run during defrost FnC 3 fans wi...

Страница 4: ...le LED MODE Function ON Compressor enabled FLASHING Programming Phase flashing with LED Anti short cycle delay enabled ON Fan enabled FLASHING Programming Phase flashing with LED ON Defrost enabled FL...

Страница 5: ...put into Pr1 user level by pressing SET DOWN When a parameter is present in Pr1 LED is on 5 5 Changing a parameter s value Each parameter is identified by a special alphanumeric code label To change...

Страница 6: ...hich causes the end of defrost dFd Temperature displayed during defrost 0 real temperature 1 temperature at defrost start 2 set point 3 dEF label dAd MAX display delay after defrost 0 120 min Sets the...

Страница 7: ...iquid infiltration It is recommended to place the thermostat probe away from air streams to correctly measure the average room temperature Place the defrost termination probe among the evaporator fins...

Страница 8: ...starts Alarms dEA and FF automatically stop after 30 minutes 10 TECHNICAL DATA Housing self extinguishing ABS Case XR160C XR162C XR172C frontal 32x74 mm depth 60mm XR170C frontal 32x74 mm depth 70mm X...

Страница 9: ...172C buzzer for an acoustic signal of alarms Data storing on the non volatile memory EEPROM Operating temperature 0 60 C Relative humidity 20 85 no condensing Storage temperature 30 85 C Measuring and...

Страница 10: ...F 1 120 Pr2 6 dSd 1 120 Pr2 0 MdF 0 120 Pr2 30 dtE 57 50 C o 196 F Pr2 8 46 dFd 0 Real 1 Start 2 Set 3 dEF Pr2 1 dAd 0 120 Pr2 30 tdF 0 Eletrical 1 Hot gas Long Time 2 Relay OFF 3 Relay ON Short time...

Отзывы: