Installing and Operating Instructions

rel.1.0 - cod. 1592009261

PR 1592009260 XW60L GB r1.0 20.03.02.doc

                           

XW60L – XW60V

4/4

10.

 

ALARM SIGNALS

Message Cause

Outputs

“P1”

Thermostat probe failure

Alarm output ON; Compressor output according to
parameters “COn” and “COF”

“P2”

Evaporator probe failure

Alarm output ON; Other outputs unchanged

“HA”

Maximum temperature alarm

Alarm output ON; Other outputs unchanged

“LA”

Minimum temperature alarm

Alarm output ON; Other outputs unchanged

“EE”

Data or memory failure

Alarm output ON; Other outputs unchanged

“dA”

Door switch alarm

Alarm output ON; Other outputs unchanged

“EAL”

External alarm

Alarm output ON; Other outputs unchanged

“BAL”

Serious external alarm

Alarm output ON; Other outputs OFF

“PAL”

Pressure switch alarm

Alarm output ON; Other outputs OFF

The alarm message is displayed until the alarm condition is recovery.
All the alarm messages are showed alternating with the room temperature except for the “P1” which is flashing.
To reset the “EE” alarm and restart the normal functioning press any key, the “

rSt

” message is displayed for

about 3s.

10.1

 

SILENCING BUZZER

Once the alarm signal is detected the buzzer can be silenced by pressing any key.

10.2

 

 “EE” ALARM

The 

dIXEL

 instruments are provided with an internal check for the data integrity. Alarm “EE” flashes when a

failure in the memory data occurs. In such cases the alarm output is enabled.

10.3

 

ALARM RECOVERY

Probe alarms

 : “

P1

” (probe1 faulty), “

P2

” ; they automatically stop 10s after the probe restarts normal operation.

Check connections before replacing the probe.

Temperature alarms

  “

HA

” and “

LA

” automatically stop as soon as the thermostat temperature returns to

normal values or when the defrost starts.

Door switch alarm

 “

dA

”  stop as soon as the door is closed.

External alarms

 “

EAL

”, “

BAL

”  stop as soon as the external digital input is disabled

Pressure switch alarm 

PAL” alarm is recovered by switching OFF the instrument

.

11.

 

TECHNICAL DATA

Housing: 

self extinguishing ABS.

Case

XW60L: 

facia 38x185 mm; depth 76mm

XW60V: 

facia 100x64 mm; depth 76mm

Mounting
XW60L:

 panel mounting in a 150x31 mm panel cut-out with two screws. 

 3 x 2mm. Distance between the

holes 165mm

XW60L:

 panel mounting in a 56x72 mm panel cut-out with two screws. 

 3x2mm. Distance between the

holes 40mm

Protection: 

IP20.

Frontal protection:

 IP65 with optional frontal gasket mod  RG-L (XW60L); RGW-V (XW60V).

Connections: 

Screw terminal block 

 2,5 mm

2

 heat-resistant wiring and 6,3mm Faston

Power supply: 

230Vac or. 110Vac 

±

 10%

Power absorption: 

7VA max.

Display

: 3 digits, red LED, 14,2 mm high.

Inputs

: 2 NTC or PTC probes

Digital input

: 1 free voltage

Relay outputs:

 Total current on loads MAX. 20A

compressor:

 relay SPST 20(8) A, 250Vac or. SPST 8(3) A, 250Vac

light: XW60L: 

relè SPDT 8(3) A, 250Vac; 

XW60V: 

relè SPST 16(6) A, 250Vac

fans:

 relay SPST 8(3) A, 250Vac

defrost:

 relay SPST 8(3) A, 250Vac

Other output :

 alarm buzzer

Data storing

: on the non-volatile memory (EEPROM).

Kind of action: 

1B.

Pollution grade: 

normal

Software class: 

A.

Operating temperature: 

0÷60 °C.

Storage temperature: 

-25÷60 °C.

Relative humidity:

 20

÷

85% (no condensing)

Measuring and regulation range:

PTC probe: 

-50÷150°C (-58÷302°F)

NTC probe: 

-40÷110°C (-58÷230°F)

Resolution: 

0,1 °C or 1°C or 1 °F (selectable).

Accuracy (ambient temp. 25°C)

:  ±0,5 °C ±1 digit

12.

 

 

CONNECTIONS

Di

gi

ta

l i

np.

 

Def.

Probe

Room

Probe

XW60L

Def.

Fan

20A

250Vac

MAX

20A

8A

250Vac

8A

250Vac

Comp

Line

Ne

ut

ra

l

8A

250Vac

13 14 15 16

12

5 6 7 8 9 10 11

1 2 3 4

17

Luce

Evap.

Probe

Room

Probe

XW60V

Def.

N.C.

Fan

Comp

Line

Ne

ut

ra

l

Light

19

12

5 6 7 8 9 10 11

2 3 4

17 18

20 21

Digital 

Input

20A

250Vac

MAX

20A

8A

250Vac

8A

250Vac

16A

250Vac

13.

 

DEFAULT SETTING VALUES

Label Name

  Range

Default

Level

REGULATION

Set

Set point

LS÷US

-5/0

Pr1

Hy

Differential

0,1÷25,5 °C / 1÷45°F

2/4

Pr1

LS

Minimum set point

 -50,0°C÷SET / -58°F÷SET

-30/-22

Pr2

US

Maximum set point

SET ÷ 110°C / SET ÷ 230°F

20/68

Pr2

OdS

Outputs activation delay at start up

0÷255 min.

0

Pr2

AC

Anti-short cycle delay

0÷30 min.

1

Pr1

CCt

Compressor ON time during fast freezing

0 ÷ 23h 50 min.

0.0

Pr2

COn

Compressor ON time with faulty probe

0÷255 min.

15

Pr2

COF

Compressor OFF time with faulty probe

0÷255 min.

30

Pr2

DISPLAY

CF

Temperature measurement unit

°C ÷ °F

°C/F

Pr2

rES

Resolution (integer/decimal point)

in ÷ de

dE/-

Pr1

Lod

Local display

P1 ÷ 1r2

P1

Pr2

DEFROST

tdF

Defrost type

rE,  rT,  in

rE

Pr2

EdF

Defrost mode

In, Sd

in

Pr2

SdF

Set point for SMART DEFROST

-30 ÷ +30°C / -22÷+86°F

0/32

Pr2

dtE

Defrost termination temperature

-50,0÷110°C/ -58÷230°F

8/46

Pr1

IdF

Interval between defrost cycles

1÷120h

6

Pr1

MdF

(Maximum) length for 1° defrost

0÷255 min.

30

Pr1

dFd

Displaying during defrost

rt, it, SEt, dEF, dEG

it

Pr2

dAd

MAX display delay after defrost

0÷255 min.

30

Pr2

dSd

Delay before defrost

0÷255 min.

0

Pr2

Fdt

Draining time

0÷60 min.

0

Pr2

dPO

First defrost after start up

n ÷ y

n

Pr2

dAF

Defrost delay after fast freezing

0 ÷ 23h 50 min.

0.0

Pr2

FANS

FnC

Fans operating mode

C-n, C-y, O-n, O-y

O-n

Pr2

Fnd

Fans delay after defrost

0÷255 min.

10

Pr2

FSt

Fans stop temperature

-50,0÷110°C/ -58÷230°F

2/36

Pr2

ALARMS

ALC

Temperature alarms configuration

rE÷Ab

Ab

Pr2

ALU

MAXIMUM temperature alarm

-50,0÷110°C/ -58÷230°F

110/230

Pr1

ALL

minimum temperature alarm

-50,0÷110°C/ -58÷230°F

-40/-40

Pr1

AFH

Temperature alarm differential

0,1÷25,5 °C / 1÷45°F

2/4

Pr2

ALd

Temperature alarm delay

0÷255 min.

15

Pr2

dAO

Delay of temperature alarm at start up

0 ÷ 23h 50 min.

1,3

Pr2

EdA

Alarm delay at the end of defrost

0÷255 min.

30

Pr2

dot

Delay of temperature alarm after closing the door

0÷255 min.

15

Pr2

dOA

Open door alarm delay

0÷255 min.

15

Pr2

nPS

Pressure switch number

0÷15

0

Pr2

ANALOGUE INPUTS

Ot

Thermostat probe calibration

-12,0÷12,0°C / -21÷21°F

0

Pr1

OE

Evaporator probe calibration

-12,0÷12,0°C / -21÷21°F

0

Pr2

P2P

Evaporator probe presence

n ÷ y

y

Pr2

HES

Temperature increasing during the Energy Saving
cycle

-30÷30°F/-54÷54°F

0

Pr2

DIGITAL INPUTS

Odc

Open door control

no, Fan, CPr, F_C

Fan

Pr2

I2P

Configurable digital input polarity

CL÷OP

CL

Pr2

i2F

Digital input configuration

dor, EAL, bAL, PAL, dFr,

AUS, ES, OnF

dor

Pr2

dId

Digital input alarm delay

0÷255 min.

5

Pr2

OTHER

Pbc

Kind of probe

PbC, ntc

ntc/Ptc

Pr2

rEL

Software release

- - -

2.0

Pr2

Ptb

Map code

- - -

- - -

Pr2

Prd

Probes display

Pb1÷Pb3

- - -

Pr2

Pr2

Access parameter list

- - -

- - -

Pr1

Dixell s.r.l. Via dell’Industria, 27
32010 Z.I Pieve d’Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13

E-mail:[email protected]  -  http://www.dixell.com