3.1 To Setup or Install Safely
!
• Do not place unit near flammables or combustible surface.
• Refer to
SECTION 2: Specifications
, to know the electrical requirements of the unit you are
installing and ensure adequate input power that is properly sized, rated, and protected.
• This unit must be grounded for safe operation.
3.2 Un-Packaging
3.3 Principles of Operation
8
SECTION 3 - SETUP / INSTALLATION
1. Immediately upon receiving the unit, carefully examine the carton for damage during transit.
2. Use lift forks to move.
3. Remove packing material.
4. Avoid tipping or inverting during handling.
5. The item serial number, model, and electrical ratings are listed on the nameplate. Record this information in
the Maintenance Record provided in
APPENDIX 2: Maintenance Record
, or your own preventative maintenance system.
This product is designed to capture volatile compounds from certain industrial applications. When operating, air is drawn
into the capture arm, and, into the Carbon Canisters, and then finally exhausted out.
This product consists of four basic components:
1.
A structure for housing all components
2.
A motor blower assembly
3.
Electrical assemblies
4.
Carbon Canister(s)
In air pollution control, adsorption is employed to remove volatile organic compounds (VOCs) from low to medium concentration
air streams. Adsorption itself is a phenomenon where air molecules passing through a bed of solid particles are selectively
held there by attractive forces. The Carbo unit uses twin carbon cylinders that contain either 50lbs or 75 lbs each. Air sampling
is recommended to effectively determine when the carbon is saturated. This saturation point will depend on frequency
of use and the concentration of VOC being pulled through the carbon canisters.
The Diversitech Canisters are shipped ready for installation with the activated carbon pre-installed. The Carbo system
should be as close to the emission source as possible.
Once the carbon reaches a certain VOC content, saturation, the unit should be shut down and the canister should be
replaced. The old carbon or canister is then returned to a reclamation center or disposed of following local environmental
laws and guidelines.
When controlling organic compounds, it is recommended that the humidity be maintained below 50%. Higher levels of
humidity will fill the carbon pores and reduce the carbon’s ability to adsorb the emissions.
3.4 Selecting a Location
• Choose a location where the unit will be used, near the operator.
• Choose a location sufficiently close to a grounded power source.