background image

23

 

 

IX. Clean and Maintenance 

 

 

1

.  General  neutral  liquid  detergent  and  soft  cloth  can  be  used  for  the  daily  cleaning  of  the 

steam  room.  Do  not  use  the  detergent  containing  the  acetone  or  ammonia  spirit. If  there  is 
any  sticky  dirt on the  tub  surface  caused by  sealing, wipe it off  gently  with  a piece  of soft 
cloth soaked with some gasoline.   
2. Use 1500# waterproof abrasive paper dipped in water to grind the scratch (if any) on the 
acrylic surface, and polish it after that with a piece of soft cloth applied with some toothpaste. 
3. Wipe off the stains on the room surface with a piece of soft cloth soaked with the weak 
acid detergent such as the heated lemon juice or vinegar.   
4. Remove the impurities such as hairs at the steam nozzle or the opening for sterilization gas 
immediately, to make such parts always unclogged.   
5. Do not wipe the gilded or chrome-plated pieces often (keep them away from any organic 
solvent)   
Note: the silicone gas with acid may damage the electroplated surface.   
6.  Never  clean  the  tub  surface  with  any  rough  tool  with  a  rough  surface  or  any  detergent 
containing chemical solvents or grains.   
7. Never hit or scrape the tub surface with a blunt object or a cutting tool.   
8. Ask the professional to remove the deposits in the steam generator after a certain times of 
thermal circulation.   
9.  Drain  off  the  remaining  water  in  the  steam  generator  each  time  after  use  to  prolong  its 
service life.   
10.Make  a  test  to  check  the  leakage  protection  performance  of  the  leakage  switch  once  a 
month  (the  leakage  switch  is  of  proper  performance  as  it  trips  when  the  test  key  on  the 
leakage protection plug is pressed. Press RESET to switch on the power supply again).   
11.  Check  the  power  wires,  switches  and  sockets  often,  to  see  if  they  are  damaged  by  the 
mice, insects or ants and cause the unnecessary loss.   
12. Check the water pipe and drainage pipe often to see if there is any breakage or bending 
causing the inconvenience in use. Always keep the drainage pipeline unblocked.   
13. Reverted storage or piled storage of this product is not permitted. Keep it away from any 
organic solvent such as the formic acid and formaldehyde.   
14. Handle the product with care, and avoid any heavy pressure, mechanical hit and strong 
vibration.   
15. Keep the surroundings dry and ventilated without any corrosive gas for the steam room 
idling for a long time, and cut off the water supply. 
 
 
 
 
 
 
 
 
We  reserve  the  rights  to  modify  and  change  the  relevant  parameters  and  to  increase  or 
decrease  the  sizes  and  models  and  configurations  of  the  product.  In  case  of  any  problem, 
please call the dealer.

   

 

Содержание WG-U692T

Страница 1: ...1 Steam Room Manual WG U692T L Model Size LxWxH mm Light Steam generator Fan Loudsp eaker faucet Top shower Hand shower WG U692T 1200x850x2230 ...

Страница 2: ... Ceiling light 8 Tray 14 Door handle 3 Computer panel 9 Top shower 15 Shower hose 4 Thermo mixer faucet 10 Shampoo shelf 16 Foot massage 5 Back jet 11 Shower pole 17 Hose of foot massage 6 Steam outlet 12 Hand shower 2 3 4 5 6 7 8 10 11 12 13 14 17 1 9 15 16 ...

Страница 3: ...ter until feel comfortable 9 When using steam function please don t use the shower or water massage function 10 Keep your body away from the outlet of steam to avoid scald 11 Never start the motor without water if steam room with massage bathtub 12 Close the door and do not enter the steam shower when the sterilization is on 13 Keep any flammable material or any object with the temperature of over...

Страница 4: ...arts Insert the wiring cords firmly and keep them away from any water pipe connector that may have water drips due to leakage Identify the connection symbols on the wiring cards before insertion as the error connection may damage the electrical parts in the steam room 2 Reliably connect the earth wire of the steam room to the indoor electrical grounding unit and make sure that it really works 3 Co...

Страница 5: ...eeze bend or clog the flexible drain pipe to make sure of the fast and smooth drainage 3 In case of any leakage of the drainer stop it up with the rubber pad or silicone VI Installation steps A Two persons are required to assemble the unit B The glass is toughened safety glass Please take great care when handling and fitting the glass panels In particular avoid the glass edges coming into contact ...

Страница 6: ...op and bottom the glass then put the glass into the track 4x16mm screw 4x20mm screw 4x20mm screw 4x25mm screw Put aluminium frame on the ground and set up as picture pay attention to protect the aluminium from scratch you can put a blanket or carton under the aluminium U shape seal ...

Страница 7: ...7 3 Install the back wall glass 4x10mm screw 5 pcs please notice this glass is big and heavy Two persons lift the frame onto the tray ...

Страница 8: ...8 4 To make the corner more fixed fasten by 4x10mm screw 2 pcs each side Install another back wall glass 4x10mm screw each side 5 pcs At the bottom fastern by 4x10mm screws ...

Страница 9: ...l the wheel don t fasten the screw of wheel too tightly now Hang door glass into the track of aluminium adjust the wheel to fit well finally fasten the screw of wheel fasten another screw 4 16mm 4 pcs Put on the cover fasten screw and nut 4 pcs ...

Страница 10: ...helf one person stand inside the steam another person stand behind the wall glass Fasten the screw from bottom Set up the base The back of shelf Install the rest accessories such as foot massage towel rail door handle etc ...

Страница 11: ... glass seal outside 2 sides of fixed glass if the seal is too hard in winter you can drop this seal into hot water to make it soft You can use a wood to help installing the seal Glass in this side Install door side seal ...

Страница 12: ...light to light loudspeaker to loudspeaker One wire of light doesn t connect fan Connect the hoses to C Check the symbols on A or B depending on your shower model on your thermo mixers front plate to find the correct position for the hoses on the back side of the mixer ...

Страница 13: ...h of the plug works well in this way press RESET with the power indicator on If the red light is still on when TEST is pressed or is not on as RESET is pressed it means that the leakage protection malfunctions or has any trouble Please call the professional to make the repair at this time 3 All functions of the steam room can be used so long as its power supply and water supply are checked as norm...

Страница 14: ...14 ...

Страница 15: ...oaction of the panel Otherwise it will lead to malfunction or trigger the panel lock 2 all function keys are located at the most convenient locations 3 When the panel is on power it will give out one sound of ring B functions introduction 1 spare massage 2 steaming 3 exhaust fan 4 FM 5 lighting 6 ozone disinfection 7 bluetooth 8 telephone 1 start up shut down and unlocking of panel startup ...

Страница 16: ...perable 2 Instruction for operation After stratup the default location of cursor will be Rotate the shuttle switch to move the cursor After the cursor moves to a function press the shuttle switch or the function keys on the remote control to quickly turn on and turn off the function The icons will light up after functions are turned on and vanish after functions are turned off 3 operating instruct...

Страница 17: ...ncrease the time or to decrease the time Timing range 5 50min Settings of temperature and time will automatically take effect in 3 seconds the system will exit the temperature and time setting mode Drainage 5 minutes after the shutdown of system the steam tank will drain water for 3 minutes 2 Spray Move the cursor to and press the shuttle switch The first press will turn on upper spray the second ...

Страница 18: ...te control to turn on or turn off the ozone After startup icon light up and all other functions will be disabled except lighting function Emission of ozone will last for 10 minutes then the exhaust fan will automatically start and operate for 15 minutes 6 Radio Function Move the cursor and press the shuttle switch or press on the remote control to turn on or turn off the radio function Icon will l...

Страница 19: ...ash for two seconds in this way at most 10 radio frequencies can be stored on different channels Frequency range 87 5 108 0MHz Switch of channels When the radio is turned on and the panel is unlocked move the cursor to press the shuttle switch rotate the shuttle switch or press on the remote control to switch channels and play programs on the stored radio channel 7 Bluetooth Turn on the system and...

Страница 20: ... of phone calls the cursor can only move between non multimedia functions and phone After the cursor moves to a non telephone icon it will automatically return to the phone icon for no operation in five seconds Multimedia control keys on the remote control will be disabled during ringing and reception of calls When a phone call comes in touch to reject the call 9 Volume control In the radio and Bl...

Страница 21: ...de The fourth press would return to the steam temperature setting As the system enters the volume adjustment mode would begin to flash on the LCD screen Operation of thermo mixer faucet Four way functions thermo mixer Foot massage Hand shower Top shower Back jet Turn on off water And adjust water volume Adjust water temperature ...

Страница 22: ...ral water valve is not open B Failure of inlet valve control system C Failure in water level detection After the steam function is turned on the system will open water inlet after it detects shortage of water If the system shows no water after 10 seconds or the tank remains unfilled after 1 minute the system would report E10 fault as well as turn off steam function and inlet valve E16 Temperature ...

Страница 23: ...g tool 8 Ask the professional to remove the deposits in the steam generator after a certain times of thermal circulation 9 Drain off the remaining water in the steam generator each time after use to prolong its service life 10 Make a test to check the leakage protection performance of the leakage switch once a month the leakage switch is of proper performance as it trips when the test key on the l...

Отзывы: