Dittmann HFE 322 Скачать руководство пользователя страница 5

5

3.3.1

3.3.2

3.3.3

3.4.1

3.4.2

3.4.3
3.4.4

3.4.5

3.4.6

3.4.7 Do not wear any jewellery or any adhesive tattoos in the area of stimulation

during application of the stimulation glove.

Do not use the stimulation glove at less than 1.5 metres distance to a short- 
or micro-wave device or a high-frequency HF surgical device, since there is a 
danger of skin irritation or burns below the electrodes. Do not use the 
stimulation glove  and the stimulator in the mountains at altitudes above 
3000 metres.

The stimulation glove may interfere with other electrical devices in applica-
tion or be interfered with by other electrical devices. Therefore, never use 
the stimulation glove close to other electrical devices.

Do not use the stimulation glove close to slightly flammable substances and 
gases or close to explosives.

Do not use the stimulation glove in bed or when sleeping.

Do not use the stimulation glove in the shower, when swimming, in the 
sauna, when bathing or in any other environment with high humidity. Keep 
any liquids and metallic objects away during application. Increased 
stimulation or short circuit may lead to injury and health damage - danger to 
life!

The stimulation glove must not be used concurrently with other medical and 
electrical devices of any kind.

3.4     For which areas of use/environments is the stimulation 
          glove not suitable?

The stimulation glove may be used in case of:
acute complaints, for plain therapy, arthritic hand, arthrosis, rheumatic com-
plaints and other chronic pain in the hands.

The stimulation glove is only intended for external use (application via the 
skin) on humans, specifically for treatment of doubtlessly diagnosed chronic 
pain.

Only use the stimulation glove for the intended use for low-frequency 
applications (max. electrical impulses in the area of up to 120 Hz) and max. 
120 mA at the hands of the human body.

3.3     For which areas of use/environments is the stimulation glove
          suitable?

SAFETY NOTES

GB

PJN-124-13_GA-GB_HHD_HFE322_ Handschuh.25.07.13

Donnerstag, 25. Juli 2013 18:44:34

Содержание HFE 322

Страница 1: ...shable by hand One stimulation glove can be controlled via one output channel of a stimulation device Can be used on the right or the left hand Content 1 stimulation glove 2 adhesive electrodes 1 conn...

Страница 2: ...the stimulation glove not be used Use of the stimulation glove Use by children and teens For which areas of application is the stimulation glove suitable For which areas of application is the stimula...

Страница 3: ...nnected per channel Attention If two stimulation gloves are used concurrently they must not touch in application There is the danger of a short circuit and increased current density This may cause dam...

Страница 4: ...tion glove to it Keep these usage instructions for later questions and hand them on along with the stimulation glove if you pass the device on to any third parties Make the usage instructions availabl...

Страница 5: ...shower when swimming in the sauna when bathing or in any other environment with high humidity Keep any liquids and metallic objects away during application Increased stimulation or short circuit may...

Страница 6: ...ion with a stimulator a in case of acute sickness b in case of tumours c in case of infectious disease d in case of fever e in case of blood pressure problems f in case of skin disease g after an acci...

Страница 7: ...glove Only pull or push the plugs to connect or remove the stimulation glove The cables and stimulation glove must only be connected when the stimula tion device TENS device is switched off Before app...

Страница 8: ...t be connected to the device stimulator for this Then let the stimulation glove dry off well Do not put it into the drier The stimulation glove must not be exposed to direct sunlight Do not place the...

Страница 9: ...ction socket A Stimulation glove 4 5 Setup of the stimulation glove 1 x usage instructions 2 x adhesive electrodes 1 x connection cable 1 x Stimulation glove 4 4 Scope of delivery packaging content SC...

Страница 10: ...is switched off when connecting it After the connection is established you may start TENS application Observe the usage instructions of the stimulation device The impulses flow from the stimulation g...

Страница 11: ...30 80 percent Storage transport temperature 5 C 50 C degrees Celsius Max humidity at storage transport 10 80 percent Approx 20 g without adhesive electrode and connection cables Metals plastics The st...

Страница 12: ...nical problems questions and warranty claims regarding this stimulation glove contact us as follows After the end of the warranty period you may send the defective stimulation glove to the address bel...

Отзывы: