Ditron DM-A Скачать руководство пользователя страница 2

Magnetic scale installation:

1. Select the mounting surface for the scale on the machine insuring that the reader head also can be

mounted in such a way to be able to travel along the length of the scale. The surface should be as flat as

possible and run parallel with the axis. Whilst there is adjustment on the brackets this is limited and still

may require packing.

2 Drill and Tap Holes:

a) Select the mounting brackets required and confirm the location of threaded holes needed to hold the

brackets to the machine. The brackets should be attached so that the scale is supported every 900 -

1000mm. Insure that the connecting brackets are also mounted so that they are in a position to connect the

extruded lengths.

b) Drill and tap M5 threaded holes on the machine surface to suit each of the brackets.

3. Mount the Scale

a) Install the scale in the mounting brackets and connecting brackets on the machine surface and secure

with the lock blocks so that the scale is secure.

b) Once the scale is installed in the mounting plates on the machine surface, using a dial indicator ad-

just the scale so that it sits in the correct location, square and in line with the axis. Adjustment screws

are mounted in each of the brackets

(c) Once the aluminium extrusion has been secured to the

mounting blocks, and is aligned, clean the aluminium so that it is

dry and free from dirt and oils. Lay the magnetic tape (sticky

face down ) in the groove in the extrusion, carefully removing the

backing paper as magnetic strip is attached to the extrusion. The

strip must sit evenly in the groove provided.

(d) Once the magnetic strip is in place, slide the metal protec-

tive strip into the grooves provided so that it covers the magnetic

strip..

(e) Attach the end caps to the two ends of the scale so that the
metal cover strip is secured..

The Reader Head Installation

1:Select the appropriate reader head mounting surface

a) Mount the reader head securely on a suitable mounting surface that will hold the reader head rigid and

secure, parallel with the magnetic strip

b) Insure that the gap between the reader head and the tape is between 0.5~1.2mm for the full length of

the scale

d) Connect the signal line of the reader head to the corresponding location on the DRO making sure that
the cable is clear of any moving parts.

Отзывы: