DRP16 -
User Guide
1.
Replaceable Battery
The DRP16 Series is equipped with a replaceable battery.
Replacement of the battery should be done with the unit in an off
position and unplugged from the wall outlet to ensure no AC
voltage exists. The battery has a limited lifespan. Battery
duration will decrease with repeated usage and age. If battery
duration becomes extremely short, it may be time to replace the
battery. The battery must be replaced with a sealed lead acid
battery rated to 12V 5.5AH. Contact your authorized DITEK
dealer.
(See battery warnings on page 7 of this manual)
2.
Internal Warning Audible Alarm
When the DRP16 is switched on, the audible alarm will sound
once for safety diagnosis. After 5 seconds, the DRP16 will check
the strength of the battery. If the battery is weak, the audible
alarm will sound continuously for 30 seconds. Alarm will sound at
any time for battery failure. Contact your authorized DITEK
dealer.
3.
Battery Test Switch
Press this button to test the status of battery. The battery
indicator LED will light up if the voltage of the battery is greater
than 11.5V.
4.
Battery Functional Indicator
When the DRP16 is powered up by the master switch, it
performs a self-test to determine battery condition. If the audible
alarm sounds for 30 seconds, the DRP16 needs to charge for 24
hours. Then, retest the battery by depressing the Battery Test
Switch. The indicator should light as the switch is depressed. If,
after charging, the indicator fails to light when the switch is
depressed, the battery needs to be replaced. Contact you
authorized DITEK dealer.
5.
Wiring Functional Indicator Light
This indicator instantly alerts you of incorrect outlet wiring at your
facility (either no ground circuit or a reversed polarity in the
building wiring). If this light is off, consult a qualified electrician to
examine your building wiring.
6.
Surge Protection Functional Indicator Light
This indicator shows the status of your AC surge protection
circuitry. This indicator is lighted when the unit has active surge
protection on the AC power circuit. Should one or more of your
camera circuits lose surge protection, it will be evidenced by
signal degradation appearing on the monitor screen for that
particular camera. Should the surge protector self sacrifice on
the data line circuit, it will be evidenced by “noise” on that line.
7.
On/Off Master Switch
The main power switch controls the power to all of the outlets. “I”
means ON and “O” means OFF.
5
DRP16 -
User Guide
DRP16T
Electrical Specifications
Class: Digital Recorder Protector / Battery Back-Up
Installation Point: Audio-video Point of Use
Connection Method: 6 Foot Power Cord
Continuous Current: 12 Amps
Response Time: <5 nS
MCOV: 130VAC
Operating Frequency: 50 – 60 Hz
AC Protection Modes: L – G, L – N, N - G
Service Voltage: 125 VAC
Diagnostics: Surge Protection Active, Line Fault, Dry Contact (120 VAC, 1A Max)
EMI/RFI Noise Filtering:
150KHz – 100mHz up to 58dB
Max. Surge Current: 58,500Amps (Peak)
Max. Energy Dissipation: 1665 Joules (Single Pulse)
Features: 4 AC Outlets, 16 - In / 16 - Out Coax, and 2 In/2Out RJ Connectors
Battery Backup Rating: 450VA / 250W (Max.)
Battery Output Voltage: -5%
Battery Charge Mode: Full Time
Battery Recharge Time: 12 Hours from total discharge (Typical)
Battery Life: 3-6 Years (Typical)
Battery Back up Response Time: 4 mS
Phone/Fax/Modem Protection Specifications
Connection Method: RJ11
Max. Spike Energy: 160 Joules
Clamping Voltage: 395V
Data Line Protection Specifications
Class: CAT5e Data Line Protector
Connection Method: Modular Plug RJ45
Continuous Current: 0.3 Amps
Response time: <1nSec
MCOV: 8VDC
Peak Pulse Power Dissipation: 3KW (10/1000uS)
Nominal Clamp Voltage: 6.8V
DVR Protection Specifications
Designed for baseband video channel signal transmission over UTP cable.
Can be used for either NTSC, SECAM or PAL video signal.
Built-in impedance matching device and filter for video signal transmission
Compatible with qualified cameras with Built-in UTP transmitter.
Class: UTP Video Protector
Connection Method: Pluggable Terminal Block
Wire size: 26-12 AWG
Peak Pulse Power Dissipation: 4.5KW (10/1000uS) per module
Nominal Clamp Voltage: 6.8V (L-G) 2.8V (L-L)
Frequency: DC-10 MHZ
Typical Insertion Loss: <0.1 dB
Characteristic Impedance: 100 Ohms
Mating Transceiver: DTK-DPBP, DTK-PVP-TPV, DTK-DP4P-TPV
14