Manuale di installazione quadro elettronico per automazione WELE.
Electronic control panel installation manual for WELE automations.
Notice d’installation de la carte électronique pour automatisme WELE.
Installationsanleitung für Steuerung WELE.
Manual de instalación cuadro electrónico para automación WELE.
Manual de instalação do quadro electrónico para a automação WELE.

OFF

ON

PG

Apertura a spinta Push&Go

Push&Go opening

Disabilitato

Disabled

Abilitato

Enabled

MIN

MAX

TA

Durata comando apre

Duration of opening command

0 s

25 s

TC

Tempo sosta apre

Open break time

0 s

25 s

VA

Velocità apre

Opening speed

10 s/90° 2 s/90°

VC

Velocità chiude 

Closing speed

8 s/90°

3 s/90°

RA

Rallentamento apre

Slow-down opening speed

/

/

TA

VC

RA

PG

FC

EL12E

FA

F2=F6,3A

3

-LK+

LO

CLOSING SPEED

ME

HI

Apertura

 / Opening

Chiusura automatica

 / Automatic closure

Sicurezza in apertura

 / Opening safety

Uscita serratura

Lock output 

24 V= / max 1,2 A

Uscita

 / Output 

24 V= / 0,5 A

Velocità di chiusura

 / Closing speed

Bassa

 / Low

Media

 / Medium

Alta

 / High

Sicurezza d’inversione

 / Safety reversal

CO

M

NC

FA

CO

M

NC

NO

F10A

AL1

Fusibile di linea

Line fuse

F1 = F1,6A

Alimentazione

Power supply

230 V~ / 50 Hz

Blu/

Blue

Nero/

Black

Verde/

Green

Grigio/

Grey

Nero/

Black

Blu/

Blue

Bianco/

White

F

GB

I

P

E

D

Содержание EL12E

Страница 1: ...ed Abilitato Enabled MIN MAX TA Durata comando apre Duration of opening command 0 s 25 s TC Tempo sosta apre Open break time 0 s 25 s VA Velocit apre Opening speed 10 s 90 2 s 90 VC Velocit chiude Clo...

Страница 2: ...lowed until the complete stop without interrupting the count of the stop time and automatic closing 1 8 N C REVERSAL SAFETY CONTACT Reverses movement re opens during closing FA N C OPENING LIMIT SWITC...

Страница 3: ...r the tripping of limit switch FA 2 4 Dip Switches Description OFF ON PG Push Go manual opening Disabled Enabled 2 5 Signals LED ON Flashing FA Indicates the activation of the open limit switch 3 DOOR...

Страница 4: ...ing COMH K function selector not working Replace COMH K function selector Thedoordoesnotopenorclose Power failure Make sure electric control panel is powered Accessories short circuit Disconnect acces...

Страница 5: ...is closed Connect the limit switch as shown in the diagram Note the closure limit switch FC WEL2 is not supplied by us with automations and must be ap plied to the leaf WEL2 WEL1 REM2 OUTSIDE REM1 OUT...

Страница 6: ...pushing or pulling of the door triggers motorized opening PG ON TA RA VC PG F2 F6 3A 3 LK LO CLOSING SPEED ME HI REM PAS PAS PUP OUTSIDE INSIDE INSIDE INSIDE 24 V 24 V 24 V WELE WELBA REM PAS PUP All...