![DITEC DOR Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/ditec/dor/dor_technical-manual_2510191011.webp)
29
IP1783EN - 2015-06-12
- Connect the limit switch wire fastons to the microswitches. Arrange the limit switch wires neatly
inside the microswitch box [1] and route the wire out through the appropriate opening.
- Fit the two cams [3] on to the cam ring without tightening the screws.
- Install the cam ring on the driving shaft and screw down screw [4] without tightening.
- Secure the microswitch box [1] to the geared motor.
- (Fig. 2-3) With gate closed, manually rotate the cam ring [2] so as to have the closing microswitch
pressed down and the opening microswitch released. Firmly secure the cam ring in this position
by means of screw [4].
WARNING: check that between the geared motor and the limit switch cams there is a gap of at
least 1 mm.
- (Fig. 2-3) With gate open, check that the opening microswitch is pressed down.
NOTE: if the opening microswitch is not pressed down, move the cam on to hole [A].
- Upon setting being completed, tighten the cam screws.
- Connect limit switches as shown in fig. 2 (for motors opening clockwise) or in fig. 3 (for motors
opening anticlockwise).
NOTE: follow VIVAH control panel instructions manual to connect.
CLOSING
OPENING
32
31
33
31
33
CL
OSING
SWIT
CH
OPENING
SWIT
CH
CL
OSING
SWIT
CH
OPENING
SWIT
CH
32
CLOSING
OPENING
OPENING
SWIT
CH
CL
OSING
SWIT
CH
OPENING
SWIT
CH
CL
OSING
SWIT
CH
33
31
32
33
31
32
Fig. 1
Fig. 2
Fig. 3
TAGLIARE
CUT
1
3
4
2
A
5.3 Limit switch installation and adjustment (optional)