background image

TherMiser TME operation

To ensure you follow the instructions correctly, please refer to the diagram below to familiarise yourself  
with the layout and meaning of each of the on-screen icons.

1. Time and time interval setting

2. Advanced settings

Press the time key        to scroll between hour/minute/day  
of the week.

In each mode press the         or         to adjust the time  
(24hr) & day (1-7). Note: Mon = 1, Sun = 7.

The time and day will now be set.

Press        so that the screen is off

Then press and hold       +        together. The unit enters the 
menu at Status 1: “SEN” and in Function 00 (flashing). 

To adjust the settings press        or

To move through menu Items 1-7 press the          button.

See the menu below

To prevent tampering and adjustment of the TherMiser unit, unit, press       for 5 
seconds       appears. To unlock, press       for 5 seconds       flashes then disappears.

Manual Override      . Press       or       to override current target temp.        appears 
and      if heat required. Automatically resets to program mode at next time interval.  

Press and hold         for 5 seconds; screen displays ‘loop’ 
(programming mode) then:

 

A.   press         screen displays “12345” 

 

B.            (up) Once Screen displays “123456”

 

C.            (up) twice Screen displays “1234567”

NOTE: In any of the above modes press         to select the time 
interval setting and target temperature; see 1.3.

Press         again to enter the 1st time period/temperature setting 
(Good morning)        factory default is (06:30 and 22°C).

Press        again and the ON time hour starts flashing  
(default: 06:30), press        or        to adjust the hour.

Press        again and the ON time minute starts flashing  
(default: 06:30), press        or        to adjust the min.

Press        again and the target temp starts flashing  
(default: 22°C), press        or        to set target temp.

Press        again to enter into the 2nd time period/temperature 
setting (leave for school/work)         repeat the steps above  
to set, or

Press        again to enter into         3rd time period/temperature 
setting and repeat as above.

Repeat through all of the remaining periods.

1.1 

SETTInG THE TIME (FACToRy DEFAULT (00:00) 

1.2 

TIME InTERVAL AnD TEMERATURE AUTo ConTRoL SETTInGS 

1.3 

SETTInG THE on/oFF TIME AnD TEMPERATURE 

Menu

no

Icon

FuncTIon

oPTIonS

FAcToRY 

SeTTInG

1

SEN

Controls sensor inputs

00: Built-in temp sensor only

01: External temp sensor only
02: Built in temp and External

Skirting Temp Sensor

Note: If no external sensor fitted,

“ERR” message displays, unit will

not function

00

2

OSV

Upper limit  

of external/ 

ThermaSkirt sensing 

temp,

5~99°C

42°C

3

DIF

Differential  

hysteresis between  

off and on again of 

external temp.

1~9°C

2°C

4

SFH

Room temperature  

upper limit

5~99°C

35°C

5

SVL

Room temperature  

lower limit

5~99°C

5°C

6

ADJ

Calibrates tem of unit to 

the room, compensating 

for external factors.

-5~+5°

0°C

7

FRE

Frost protection

00: Frost protection OFF

01: Frost protection ON. 5°C

00

8

PON

Power on memory

00: Auto memory, no power

01: NO power = no memory

00

9

FAC

Factory reset

Adjust using     until“00”

then press      to restore 

factory settings

00

2.1 

EnTERInG InTo ADVAnCED SETTInGS MEnU* 

2.2 

LoCK SCREEn/MEnU 

2.3 

LoCK SCREEn/MEnU 

These are advanced settings and should be adjusted with caution.