background image

805-0002 REV C

Operating Manual

4-13511 Crestwood Place,

Richmond, BC, V6V 2E9, Canada

discoverbattery.com

15-24-1000   

15-36-1000

1. Safety

2

1.1 Warnings, Cautions and Notes

2

1.2 General Warning

2

1.3 Fire Risk

2

1.4 Electric Shock Risk

2

1.5 Chemical Risk

3

1.6 Do’s

3

1.7 Do Not’s

3

1.8 DC Motor Connection 

3

1.9 Transportation 

3

2. Operating Limits

3

2.1 Battery Operating Limits

3

3. Design Features & Components

4

3.1 Battery Management System (BMS)

4

3.2 Fuse

4

3.3 Terminals

4

4. Handling

4

5. Installation - Single Battery

4

5.1 Tools

5

5.2 Securing Battery

5

5.3 Installation

5

6. Operation

5

6.1 On-Off

5

6.2 Charging

5

6.3 Charge Curve

6

6.4 Discharging

6

6.5 Storage

6

7. Protection and Faults

7

7.1 Faults

7

8. Service & Maintenance

8

8.1 Inspection

8

9. Troubleshooting

8

9.1 Battery Won’t Turn On 

8

10. Recycling and Disposal

8

11. 15-24-1000 Technical Specifications

9

12. 15-36-1000 Technical Specifications

10

Содержание 15-24-1000

Страница 1: ...1 Battery Operating Limits 3 3 Design Features Components 4 3 1 Battery Management System BMS 4 3 2 Fuse 4 3 3Terminals 4 4 Handling 4 5 Installation Single Battery 4 5 1Tools 5 5 2 Securing Battery 5...

Страница 2: ...the battery Read all the instructions before installation operation and maintenance This product must be recycled and is made of recycled products CAUTION Do not disassemble or modify the battery If t...

Страница 3: ...s Do not expose battery to high temperatures Do not install with other battery types or brands 1 8 DC Motor Connection Direct connection to DC motors without proper safety protection motor controllers...

Страница 4: ...ult events cause switch to open and battery to shut down after a 120s delay Communication Ports BMS has an isolated RS232 communication port for service technician use only 3 2 Fuse Fuse provides back...

Страница 5: ...llation Improper cable sizing Improper terminal torque NOTE Without exception product experiencing terminal burn out will not be warranted 6 Operation NOTE Review operating limits 6 1 On Off To turn t...

Страница 6: ...Qualification phase for auto on feature optional 2 Charge at constant current to 3 4Vdc per cell module Bulk 3 Maintain constant voltage 3 4Vdc per cell module Absorption 4 Terminate when charge curre...

Страница 7: ...ver Voltage Stop charge Over Current Reduce current Over Temperature Stop using let cool Short Circuit Check external circuits FLASHING LED 7 FAULT LEVELS Parameter Trigger Point High Temperature in D...

Страница 8: ...ymptom Does the battery turn on for a short time then turns itself off Description The battery is likely in a low voltage or low SOC state Check to see if the blue light is blinking This indicates a l...

Страница 9: ...Shipping Dimensions HxWxD 248 x 250 x 340 mm Shipping Weight 13 kg Terminal A2 M6 Terminal Hardware M6 Stainless Steel Bolt Flat Washer Lock Washer Supplied TerminalTorque 7 0 7 7 Nm Case Material PC...

Страница 10: ...t 12 4 kg Shipping Dimensions HxWxD 248 x 250 x 340 mm Shipping Weight 13 kg Terminal A2 M6 Terminal Hardware M6 Stainless Steel Bolt Flat Washer Lock Washer Supplied TerminalTorque 7 0 7 7 Nm Case Ma...

Отзывы: