PS 6000 Power Supply

General description 

The  PS  6000  Power  Supply  provides  additional 
Power for the DCS 6000 system.  

One  CU  6005/6010  Central  Unit  is  needed in each 
DCS  6000  system;  however  for  expansion  of  the 
system  the  PS  6000  Power  Supply  is  suitable.  The 
PS 6000 consists of: 

 

One Power Supply 

 

Control electronic for detecting system power 

Features 

The  main  features  of  the  PS  6000  Power  Supply 
are: 

 

Built  in  Power  Supply  for  app  60  units 
(Delegates) or app. 150 Channel Selectors 

 

One  connector  for  connection  to  Delegate 
Units, Interpreter Units etc.  

 

One connector for connection previous unit (i.e. 
CU 6005/6010. 

 

Delayed switching on of power to minimise the 
total ‘switch-on’ current on the Mains supply. 

 

Designed in a small size easy-to-install cabinet. 

Connectors 

The  PS  6000  Power  Supply  features  the  following 
connectors: 

 

Power connector 

 

Connection for main power.  

 

Loop through connectors 

RJ45 connector, 2 pieces 

DCS-LAN  connectors  used  for  connection  to  the 
CU  6005/6010  and  for  connection  to  other  units 
with DCS-LAN connectors such as more PS 6000.  

 

Power LED 

 

Those green LED light up when Power is available 
on the connector next to the LED. 

System design 

There  are  no  settings  to  be  done  on  the  PS  6000 
Power Supply.  

However it is important to observe, that the unit is 
only  adding  power to  one of  the  chains  on the  CU 
6005/6010 Central Unit.  

And as so, the specification, which applies the two 
chain  outputs  on  the  CU  6005  Central  Unit  and  to 
each  of  the  chain  outputs  on  the  CU  6010  Central 
Unit, does also apply to the output on the PS 6000. 

And  the  PS  6000  is  NOT  a  repeater,  which  means 
that  the  maximum  cable  length  in  a  chain  (which 
without repeater is 200 m) has to be calculated from 
the last unit with repeater functionality (typically a 
CU  6005/6010,  EX  6010  or  RP  6004)  to  the  last 
unit connected to the PS 6000.  

This includes interconnection cables between the 
units.  

 

Содержание PS 6000

Страница 1: ...DCS 6000 User Manual Danish Interpretation Systems DIS Digital Conference System PS 6000 Power Supply ...

Страница 2: ...rpretation Systems User Manual Copyright 2007 DIS PS6000 REV B DOC 21 05 2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher ...

Страница 3: ... 6 Conference equipment and channel selectors 6 Operating instructions 7 PS 6000 Power Supply 7 General description 7 Features 7 Connectors 7 System design 7 Use of PS 6000 8 System Setup 9 General guidelines 9 Max number of units to be connected 10 CM DM 60x0P Chairman Delegate Units 10 CM DM 60x0P Chairman Delegate Units JB 6002 Junction Box 10 CM DM 6060F 6510F Chairman Delegate Units 11 CM DM ...

Страница 4: ... personnel Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Set the Power switch to OFF if it is not used for several days The equipment must be connected to earth Installation precautions Allow adequate air circulation to prevent internal heat built up Do not place the unit on a surface rugs blankets etc...

Страница 5: ...he system Using screened CAT5 or CAT5e cabling FTP or STP ensuring a very cost effective installation and easy set up of portable systems Firmware in Delegate units Interpreter Units Central Units etc upgradeable through serial PC connection RS232 or RS422 Can be operated with or without a PC Added functionality and comprehensive features provided by SW 6000 software package running on PC RS232 RS...

Страница 6: ... portable DM 6060P Conference Unit portable with one built in channel selector CM DM 6070P Conference Unit portable with two built in channel selectors CM DM 6090P Conference Unit portable with two built in channel selectors and XLR microphone connector CM DM 6060F Conference Unit flush mounted with one built in channel selectors CM DM 6510F Conference Unit flush mounted with Chip card and 3 votin...

Страница 7: ...res the following connectors Power connector Connection for main power Loop through connectors RJ45 connector 2 pieces DCS LAN connectors used for connection to the CU 6005 6010 and for connection to other units with DCS LAN connectors such as more PS 6000 Power LED Those green LED light up when Power is available on the connector next to the LED System design There are no settings to be done on t...

Страница 8: ... 6000 chain where extra power is needed The PS 6000 is used when extra power is needed typically where long feeding cables are needed A typical application is to place a PS 6000 in the first Interpreter Booth to compensate for a long feeding cable The following schematic shows various ways in how to use the PS 6000 Power Supply ...

Страница 9: ...m the PS 6000 to the units connected If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long and or the cables are long between the units Please consult the next section Max Number of units to be connected If the last unit in one chain is a CS 6032 Channel Selector this unit has to be terminated with an external termi...

Страница 10: ...umber of CM DM 60x0 pr output 10 m 1 m 51 m 42 30 m 1 m 67 m 38 50 m 1 m 83 m 34 100 m 1 m 123 m 24 150 m 1 m 165 m 16 10 m 2 m 88 m 40 30 m 2 m 98 m 35 50 m 2 m 108 m 30 100 m 2 m 142 m 22 150 m 2 m 180 m 16 CM DM 60x0P Chairman Delegate Units JB 6002 Junction Box This configuration shows two CM DM 60x0 Delegate Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB 6...

Страница 11: ... AWG24 Length of inter connecting Cable Type CAT5 AWG24 Total cable length Max number of CM DM 60x0 pr output 10 m 1 m 39 m 30 30 m 1 m 56 m 27 50 m 1 m 73 m 24 100 m 1 m 115 m 16 150 m 1 m 160 m 11 10 m 2 m 64 m 28 30 m 2 m 78 m 25 50 m 2 m 94 m 23 100 m 2 m 130 m 16 150 m 2 m 170 m 11 CM DM 6560F Chairman Delegate Units Length of Feeding Cable Type CAT5 AWG24 Length of inter connecting Cable Typ...

Страница 12: ...are the number of units which could have been connected CU EX but where the total number of units has been lowered due to the restriction of the maximum length of cable 200 m IS 6132P Interpreter Units This table shows the maximum number of IS 6132P Interpreter Sets which can be connected The numbers are with no audio in loudspeaker no loudspeaker connected to each unit If loudspeakers are used th...

Страница 13: ... 0 150 m 5 m 5 4 4 CS 6032F Channel Selector w back light on Length of Feeding Cable Type CAT5 AWG24 Length of Inter connecting cable Type CAT5 AWG24 Total cable length Max number of CS 6032 pr output 30 m 1 m 139 m 110 50 m 1 m 144 m 95 100 m 1 m 184 m 85 150 m 1 m 200 m 51 67 10 m 2 m 200 m 96 30 m 2 m 200 m 86 90 50 m 2 m 200 m 76 85 100 m 2 m 200 m 51 70 150 m 2 m 200 m 26 60 Numbers in are th...

Страница 14: ...les can normally only be terminated in sockets female and not in cable plugs CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels Accessories not supplied Cat 5e Connection Cables AWG24 EC 6000 5 Connection Cable 0 5 m 10 03 12500 EC 6000 01 Connection Cable 1 m 10 03 13101 EC 6000 02 Connection Cable 2 m 10 03 13201 EC 6000 05 Connection Cable 5 m 10 03 13...

Отзывы: